These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 2038626)
21. Biomechanical testing of locking and nonlocking plates in the canine scapula. Acquaviva AE; Miller EI; Eisenmann DJ; Stone RT; Kraus KH J Am Anim Hosp Assoc; 2012; 48(6):372-8. PubMed ID: 23033465 [TBL] [Abstract][Full Text] [Related]
22. Biomechanical concepts applicable to minimally invasive fracture repair in small animals. Chao P; Lewis DD; Kowaleski MP; Pozzi A Vet Clin North Am Small Anim Pract; 2012 Sep; 42(5):853-72, v. PubMed ID: 23040297 [TBL] [Abstract][Full Text] [Related]
23. Use and misuse of full cerclage wires in fracture repair. Withrow SJ Vet Clin North Am; 1978 May; 8(2):201-12. PubMed ID: 685064 [No Abstract] [Full Text] [Related]
25. Locking T-Plate Repair of Ilial Fractures in Cats and Small Dogs. Scrimgeour AB; Craig A; Witte PG Vet Comp Orthop Traumatol; 2017 Nov; 30(6):453-460. PubMed ID: 29202509 [No Abstract] [Full Text] [Related]
26. Biomechanical comparison of two locking plate constructs under cyclic torsional loading in a fracture gap model. Two screws versus three screws per fragment. Bilmont A; Palierne S; Verset M; Swider P; Autefage A Vet Comp Orthop Traumatol; 2015; 28(5):323-30. PubMed ID: 26219753 [TBL] [Abstract][Full Text] [Related]
27. Complications of appendicular fracture repair in cats and small dogs using locking compression plates. Vallefuoco R; Le Pommellet H; Savin A; Decambron A; Manassero M; Viateau V; Gauthier O; Fayolle P Vet Comp Orthop Traumatol; 2016; 29(1):46-52. PubMed ID: 26511152 [TBL] [Abstract][Full Text] [Related]
28. Biomechanical comparison of a 3.5-mm conical coupling plating system and a 3.5-mm locking compression plate applied as plate-rod constructs to an experimentally created fracture gap in femurs of canine cadavers. Tremolada G; Lewis DD; Paragnani KL; Conrad BP; Kim SE; Pozzi A Am J Vet Res; 2017 Jun; 78(6):712-717. PubMed ID: 28541152 [TBL] [Abstract][Full Text] [Related]
29. Management of infected fractures. Osteomyelitis. Nunamaker DM Vet Clin North Am; 1975 May; 5(2):259-71. PubMed ID: 1096437 [No Abstract] [Full Text] [Related]
30. Internal fixation of comminuted transverse scapular fracture in a foal. Bukowiecki CF; van Ee RT; Schneiter HL J Am Vet Med Assoc; 1989 Sep; 195(6):781-3. PubMed ID: 2793548 [TBL] [Abstract][Full Text] [Related]
31. Open reduction and bone plate stabilization, compared with closed reduction and external fixation, for treatment of comminuted tibial fractures: 47 cases (1980-1995) in dogs. Dudley M; Johnson AL; Olmstead M; Smith CW; Schaeffer DJ; Abbuehl U J Am Vet Med Assoc; 1997 Oct; 211(8):1008-12. PubMed ID: 9343545 [TBL] [Abstract][Full Text] [Related]
32. T-plate repair of fracture of the nasal bones in a horse. Burba DJ; Collier MA J Am Vet Med Assoc; 1991 Oct; 199(7):909-12. PubMed ID: 1769881 [TBL] [Abstract][Full Text] [Related]
33. Double-plate fixation of comminuted fractures of the second phalanx in horses: 10 cases (1985-1993). Crabill MR; Watkins JP; Schneider RK; Auer JA J Am Vet Med Assoc; 1995 Dec; 207(11):1458-61. PubMed ID: 7493876 [TBL] [Abstract][Full Text] [Related]
34. Screw Loosening and Pelvic Canal Narrowing After Lateral Plating of Feline Ilial Fractures With Locking and Nonlocking Plates. Schmierer PA; Kircher PR; Hartnack S; Knell SC Vet Surg; 2015 Oct; 44(7):900-4. PubMed ID: 26256446 [TBL] [Abstract][Full Text] [Related]
35. An in vitro biomechanical comparison between prototype tapered shaft cortical bone screws and AO cortical bone screws for an equine metacarpal dynamic compression plate fixation of osteotomized equine third metacarpal bones. Sod GA; Hubert JD; Martin GS; Gill MS Vet Surg; 2006 Oct; 35(7):634-42. PubMed ID: 17026548 [TBL] [Abstract][Full Text] [Related]
36. Orthopedic fixation device failure. Ackerman N; Silverman S Mod Vet Pract; 1979 Feb; 60(2):154-9. PubMed ID: 460169 [No Abstract] [Full Text] [Related]
37. Biomechanical Comparison of Two Locking Plate Constructs Under Cyclic Loading in Four-Point Bending in a Fracture Gap Model: Two Screws versus Three Screws Per Fragment. Palierne S; Froidefond B; Swider P; Autefage A Vet Comp Orthop Traumatol; 2019 Jan; 32(1):59-66. PubMed ID: 30646412 [TBL] [Abstract][Full Text] [Related]
38. Orthopedic hardware and equipment for the beginner. Part 2: plates and screws. Harasen G Can Vet J; 2011 Dec; 52(12):1359-60. PubMed ID: 22654146 [No Abstract] [Full Text] [Related]
39. Effect of fixation method on postoperative complication rates after surgical stabilization of lateral humeral condylar fractures in dogs. Perry KL; Bruce M; Woods S; Davies C; Heaps LA; Arthurs GI Vet Surg; 2015 Feb; 44(2):246-55. PubMed ID: 25243596 [TBL] [Abstract][Full Text] [Related]
40. Internal fixation of severe maxillofacial fractures in dogs. Arzi B; Verstraete FJ Vet Surg; 2015 May; 44(4):437-42. PubMed ID: 24512370 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]