These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 20387345)

  • 1. The role of sedation and pulse oximetry during upper gastrointestinal endoscopy.
    Sharma SK; Maharjan DK; Thapa PB; Adhikari SB; Byenjankar B; Khadka S; Gurung R
    JNMA J Nepal Med Assoc; 2009; 48(174):92-8. PubMed ID: 20387345
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypoxia during upper gastrointestinal endoscopy with and without sedation and the effect of pre-oxygenation on oxygen saturation.
    Wang CY; Ling LC; Cardosa MS; Wong AK; Wong NW
    Anaesthesia; 2000 Jul; 55(7):654-8. PubMed ID: 10919420
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulse oximetry during gastrointestinal endoscopic procedures.
    Sarwar S; Alam A; Khan AA
    J Coll Physicians Surg Pak; 2006 Feb; 16(2):97-100. PubMed ID: 16499799
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Arterial oxygen saturation in sedated patients undergoing gastrointestinal endoscopy and a review of pulse oximetry.
    Visco DM; Tolpin E; Straughn JC; Fagraeus L
    Del Med J; 1989 Oct; 61(10):533-42. PubMed ID: 2606231
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiorespiratory compromise under conscious sedation during upper gastrointestinal endoscopy.
    A B; A S; A S; A D; V G
    J Coll Physicians Surg Pak; 2006 Sep; 16(9):585-9. PubMed ID: 16945231
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial.
    Lightdale JR; Goldmann DA; Feldman HA; Newburg AR; DiNardo JA; Fox VL
    Pediatrics; 2006 Jun; 117(6):e1170-8. PubMed ID: 16702250
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Supplemental oxygen during moderate sedation and the occurrence of clinically significant desaturation during endoscopic procedures.
    Rozario L; Sloper D; Sheridan MJ
    Gastroenterol Nurs; 2008; 31(4):281-5. PubMed ID: 18708832
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Changes in pulse oximetry levels and factors affecting oxygen saturation during routine upper gastrointestinal endoscopy with or without sedation.
    Kiliç M; Bayan K; Yilmaz S; Tüzün Y; Dursun M; Canoruç F
    Turk J Gastroenterol; 2006 Dec; 17(4):279-82. PubMed ID: 17205406
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Patient Monitoring and Associated Devices during Endoscopic Sedation].
    Moon SH; Kim HK; Myung DS; Yoon SM; Moon W
    Korean J Gastroenterol; 2017 Jan; 69(1):64-67. PubMed ID: 28135793
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does pulse oximetry accurately monitor a patient's ventilation during sedated endoscopy under oxygen supplementation?
    Arakawa H; Kaise M; Sumiyama K; Saito S; Suzuki T; Tajiri H
    Singapore Med J; 2013 Apr; 54(4):212-5. PubMed ID: 23624448
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The safety of combined sedation with propofol plus fentanyl for endoscopy screening and endoscopic variceal ligation in cirrhotic patients.
    Mao W; Wei XQ; Tao J; Zhen FP; Wen ZF; Wu B
    J Dig Dis; 2014 Mar; 15(3):124-30. PubMed ID: 24224839
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Role of pulse oximetric monitoring during gastrointestinal endoscopy. Prospective multicenter study of the Gastroenterology Working Group of the Veszprém Regional Committee of the Hungarian Academy of Sciences (VEAB)].
    Döbrönte Z; Szenes M; Gasztonyi B; Csermely L; Kovács M; Lakatos L; Lakner L; Mester G; Pandur T; Patai A; Pák P; Pécsi G; Rácz I; Sarang K; Stöckert A; Székely A; Varga Szabó L
    Orv Hetil; 2013 May; 154(21):825-33. PubMed ID: 23692877
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Conscious sedation for upper digestive endoscopy performed by endoscopists.
    Kauling AL; Locks Gde F; Brunharo GM; da Cunha VJ; de Almeida MC
    Rev Bras Anestesiol; 2010; 60(6):577-83, 320-3. PubMed ID: 21146053
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiorespiratory changes during upper gastrointestinal endoscopy.
    Osinaike BB; Akere A; Olajumoke TO; Oyebamiji EO
    Afr Health Sci; 2007 Jun; 7(2):115-9. PubMed ID: 17594289
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of supplemental oxygen in sedated and unsedated patients undergoing upper gastrointestinal endoscopy.
    al-Qorain A; Adu-Gyamfi Y; Larbi EB; al-Shedokhi F
    J Int Med Res; 1993; 21(4):165-70. PubMed ID: 8112474
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computer-assisted personalized sedation for upper endoscopy and colonoscopy: a comparative, multicenter randomized study.
    Pambianco DJ; Vargo JJ; Pruitt RE; Hardi R; Martin JF
    Gastrointest Endosc; 2011 Apr; 73(4):765-72. PubMed ID: 21168841
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pulse oximetry monitoring during non-sedated upper gastrointestinal endoscopy.
    Melleney EM; Lambertini L; Willoughby CP
    Postgrad Med J; 1995 Jul; 71(837):433-4. PubMed ID: 7567739
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Utility of endtidal carbon dioxide monitoring in detection of hypoxia during sedation for brain magnetic resonance imaging in children with developmental disabilities.
    Kannikeswaran N; Chen X; Sethuraman U
    Paediatr Anaesth; 2011 Dec; 21(12):1241-6. PubMed ID: 21824212
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Conscious sedation in the emergency department: the value of capnography and pulse oximetry.
    Wright SW
    Ann Emerg Med; 1992 May; 21(5):551-5. PubMed ID: 1570912
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Conscious sedation : clues for diagnosing obstructive sleep apnea syndrome.
    Unler GK; Gokturk HS; Dogan R; Kivane T; Karakoca A
    Acta Gastroenterol Belg; 2016; 79(3):289-293. PubMed ID: 27821023
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.