BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

317 related articles for article (PubMed ID: 20390136)

  • 1. Three-dimensional Mach-Zehnder interferometer in a microfluidic chip for spatially-resolved label-free detection.
    Crespi A; Gu Y; Ngamsom B; Hoekstra HJ; Dongre C; Pollnau M; Ramponi R; van den Vlekkert HH; Watts P; Cerullo G; Osellame R
    Lab Chip; 2010 May; 10(9):1167-73. PubMed ID: 20390136
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Integration of femtosecond laser written optical waveguides in a lab-on-chip.
    Vazquez RM; Osellame R; Nolli D; Dongre C; van den Vlekkert H; Ramponi R; Pollnau M; Cerullo G
    Lab Chip; 2009 Jan; 9(1):91-6. PubMed ID: 19209340
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optical sensing in microfluidic lab-on-a-chip by femtosecond-laser-written waveguides.
    Martinez Vazquez R; Osellame R; Cretich M; Chiari M; Dongre C; Hoekstra HJ; Pollnau M; van den Vlekkert H; Ramponi R; Cerullo G
    Anal Bioanal Chem; 2009 Feb; 393(4):1209-16. PubMed ID: 18839156
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Single cell detection using a glass-based optofluidic device fabricated by femtosecond laser pulses.
    Kim M; Hwang DJ; Jeon H; Hiromatsu K; Grigoropoulos CP
    Lab Chip; 2009 Jan; 9(2):311-8. PubMed ID: 19107290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Femtosecond laser processing for optofluidic fabrication.
    Sugioka K; Cheng Y
    Lab Chip; 2012 Oct; 12(19):3576-89. PubMed ID: 22820547
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optofluidic chip for single cell trapping and stretching fabricated by a femtosecond laser.
    Bragheri F; Ferrara L; Bellini N; Vishnubhatla KC; Minzioni P; Ramponi R; Osellame R; Cristiani I
    J Biophotonics; 2010 Apr; 3(4):234-43. PubMed ID: 20301123
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Femtosecond laser fabricated monolithic chip for optical trapping and stretching of single cells.
    Bellini N; Vishnubhatla KC; Bragheri F; Ferrara L; Minzioni P; Ramponi R; Cristiani I; Osellame R
    Opt Express; 2010 Mar; 18(5):4679-88. PubMed ID: 20389480
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microfabricated polymer chip with integrated U-bend waveguides for evanescent field absorption based detection.
    Prabhakar A; Mukherji S
    Lab Chip; 2010 Mar; 10(6):748-54. PubMed ID: 20221563
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Embellishment of microfluidic devices via femtosecond laser micronanofabrication for chip functionalization.
    Wang J; He Y; Xia H; Niu LG; Zhang R; Chen QD; Zhang YL; Li YF; Zeng SJ; Qin JH; Lin BC; Sun HB
    Lab Chip; 2010 Aug; 10(15):1993-6. PubMed ID: 20508876
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-visibility optofluidic Mach-Zehnder interferometer.
    Testa G; Huang Y; Sarro PM; Zeni L; Bernini R
    Opt Lett; 2010 May; 35(10):1584-6. PubMed ID: 20479816
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Femtosecond laser-inscribed fiber interface Mach-Zehnder interferometer for temperature-insensitive refractive index measurement.
    Zhang Y; Lin C; Liao C; Yang K; Li Z; Wang Y
    Opt Lett; 2018 Sep; 43(18):4421-4424. PubMed ID: 30211880
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fiber in-line Mach-Zehnder interferometer constructed by selective infiltration of two air holes in photonic crystal fiber.
    Yang M; Wang DN; Wang Y; Liao CR
    Opt Lett; 2011 Mar; 36(5):636-8. PubMed ID: 21368932
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microfabricated polymer analysis chip for optical detection.
    Fleger M; Siepe D; Neyer A
    IEE Proc Nanobiotechnol; 2004 Aug; 151(4):159-61. PubMed ID: 16475861
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Silicon photonic wire biosensor array for multiplexed real-time and label-free molecular detection.
    Densmore A; Vachon M; Xu DX; Janz S; Ma R; Li YH; Lopinski G; Delâge A; Lapointe J; Luebbert CC; Liu QY; Cheben P; Schmid JH
    Opt Lett; 2009 Dec; 34(23):3598-600. PubMed ID: 19953132
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A single-layer, planar, optofluidic Mach-Zehnder interferometer for label-free detection.
    Lapsley MI; Chiang IK; Zheng YB; Ding X; Mao X; Huang TJ
    Lab Chip; 2011 May; 11(10):1795-800. PubMed ID: 21479332
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integrated optical frequency-resolved Mach-Zehnder interferometers for label-free affinity sensing.
    Kitsara M; Misiakos K; Raptis I; Makarona E
    Opt Express; 2010 Apr; 18(8):8193-206. PubMed ID: 20588665
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Mach-Zehnder interferometer based on silicon oxides for biosensor applications.
    Hong J; Choi JS; Han G; Kang JK; Kim CM; Kim TS; Yoon DS
    Anal Chim Acta; 2006 Jul; 573-574():97-103. PubMed ID: 17723511
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Femtosecond laser microfabricated fiber Mach-Zehnder interferometer for sensing applications.
    Lu P; Chen Q
    Opt Lett; 2011 Jan; 36(2):268-70. PubMed ID: 21263522
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Broad-band Mach-Zehnder interferometers as high performance refractive index sensors: theory and monolithic implementation.
    Misiakos K; Raptis I; Salapatas A; Makarona E; Botsialas A; Hoekman M; Stoffer R; Jobst G
    Opt Express; 2014 Apr; 22(8):8856-70. PubMed ID: 24787775
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optofluidic chip with directly printed polymer optical waveguide Mach-Zehnder interferometer sensors for label-free biodetection.
    Wang H; Chen Z; Li T; Xie H; Yin B; Wong SHD; Shi Y; Zhang AP
    Biomed Opt Express; 2024 May; 15(5):3240-3250. PubMed ID: 38855677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.