212 related articles for article (PubMed ID: 20393235)
1. Evaluation and optimization of the new EBT2 radiochromic film dosimetry system for patient dose verification in radiotherapy.
Richley L; John AC; Coomber H; Fletcher S
Phys Med Biol; 2010 May; 55(9):2601-17. PubMed ID: 20393235
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
Ferreira BC; Lopes MC; Capela M
Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
[TBL] [Abstract][Full Text] [Related]
3. A comparison between radiochromic EBT2 film model and its predecessor EBT film model.
Carrasco MA; Perucha M; Luis FJ; Baeza M; Herrador M
Phys Med; 2013 Jun; 29(4):412-22. PubMed ID: 22738767
[TBL] [Abstract][Full Text] [Related]
4. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
Paelinck L; De Neve W; De Wagter C
Phys Med Biol; 2007 Jan; 52(1):231-42. PubMed ID: 17183138
[TBL] [Abstract][Full Text] [Related]
5. Quantitative investigation of the effects of the scanning parameters in the digitization of EBT and EBT2 Gafchromic film dosimetry with flatbed scanners.
Hu Y; Ahmad S; Ali I
J Xray Sci Technol; 2012; 20(4):385-93. PubMed ID: 23324780
[TBL] [Abstract][Full Text] [Related]
6. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.
Chang L; Chui CS; Ding HJ; Hwang IM; Ho SY
Phys Med Biol; 2012 Sep; 57(18):5875-87. PubMed ID: 22951587
[TBL] [Abstract][Full Text] [Related]
7. Variations in dose distribution and optical properties of Gafchromic(TM) EBT2 film according to scanning mode.
Park S; Kang SK; Cheong KH; Hwang T; Kim H; Han T; Lee MY; Kim K; Bae H; Su Kim H; Han Kim J; Jae Oh S; Suh JS
Med Phys; 2012 May; 39(5):2524-35. PubMed ID: 22559623
[TBL] [Abstract][Full Text] [Related]
8. Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.
Mendez I; Hartman V; Hudej R; Strojnik A; Casar B
Med Phys; 2013 Jan; 40(1):011720. PubMed ID: 23298090
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
Fuss M; Sturtewagen E; De Wagter C; Georg D
Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604
[TBL] [Abstract][Full Text] [Related]
10. Measuring solar UV radiation with EBT radiochromic film.
Butson ET; Cheung T; Yu PK; Butson MJ
Phys Med Biol; 2010 Oct; 55(20):N487-93. PubMed ID: 20858922
[TBL] [Abstract][Full Text] [Related]
11. Analysis of uncertainties in Gafchromic EBT film dosimetry of photon beams.
Martisíková M; Ackermann B; Jäkel O
Phys Med Biol; 2008 Dec; 53(24):7013-27. PubMed ID: 19015581
[TBL] [Abstract][Full Text] [Related]
12. A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT.
Andrés C; del Castillo A; Tortosa R; Alonso D; Barquero R
Med Phys; 2010 Dec; 37(12):6271-8. PubMed ID: 21302783
[TBL] [Abstract][Full Text] [Related]
13. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films.
Dreindl R; Georg D; Stock M
Z Med Phys; 2014 May; 24(2):153-63. PubMed ID: 24055395
[TBL] [Abstract][Full Text] [Related]
14. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.
Rampado O; Garelli E; Deagostini S; Ropolo R
Phys Med Biol; 2006 Jun; 51(11):2871-81. PubMed ID: 16723772
[TBL] [Abstract][Full Text] [Related]
15. Post-irradiation colouration of Gafchromic EBT radiochromic film.
Cheung T; Butson MJ; Yu PK
Phys Med Biol; 2005 Oct; 50(20):N281-5. PubMed ID: 16204869
[TBL] [Abstract][Full Text] [Related]
16. The response of the new MD-V2-55 radiochromic film exposed to 60Co gamma rays.
Massillon-Jl G; Zúñiga-Meneses L
Phys Med Biol; 2010 Sep; 55(18):5437-49. PubMed ID: 20736498
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification.
Sankar A; Ayyangar KM; Nehru RM; Kurup PG; Murali V; Enke CA; Velmurugan J
Med Dosim; 2006; 31(4):273-82. PubMed ID: 17134667
[TBL] [Abstract][Full Text] [Related]
18. Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry.
Desroches J; Bouchard H; Lacroix F
Med Phys; 2010 Apr; 37(4):1565-70. PubMed ID: 20443477
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance.
Aland T; Kairn T; Kenny J
Australas Phys Eng Sci Med; 2011 Jun; 34(2):251-60. PubMed ID: 21465275
[TBL] [Abstract][Full Text] [Related]
20. Independence of calibration curves for EBT Gafchromic films of the size of high-energy X-ray fields.
Cheung T; Butson MJ; Yu PK
Appl Radiat Isot; 2006 Sep; 64(9):1027-30. PubMed ID: 16774834
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]