BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 20403933)

  • 1. Positioning for lumbar puncture in children evaluated by bedside ultrasound.
    Abo A; Chen L; Johnston P; Santucci K
    Pediatrics; 2010 May; 125(5):e1149-53. PubMed ID: 20403933
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Positioning of infants in the neonatal intensive care unit for lumbar puncture as determined by bedside ultrasonography.
    Öncel S; Günlemez A; Anik Y; Alvur M
    Arch Dis Child Fetal Neonatal Ed; 2013 Mar; 98(2):F133-5. PubMed ID: 22684159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluating infant positioning for lumbar puncture using sonographic measurements.
    Cadigan BA; Cydulka RK; Werner SL; Jones RA
    Acad Emerg Med; 2011 Feb; 18(2):215-8. PubMed ID: 21314783
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hip flexion and lumbar puncture: a radiological study.
    Fisher A; Lupu L; Gurevitz B; Brill S; Margolin E; Hertzanu Y
    Anaesthesia; 2001 Mar; 56(3):262-6. PubMed ID: 11251435
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasound Measurement of the Intervertebral Space in the Lateral Recumbent Versus Sitting Positions.
    Shi D; Perice L; Grimaldi C; Perera T; Nelson M
    J Emerg Med; 2021 Dec; 61(6):705-710. PubMed ID: 34465511
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal patient position for lumbar puncture, measured by ultrasonography.
    Sandoval M; Shestak W; Stürmann K; Hsu C
    Emerg Radiol; 2004 Feb; 10(4):179-81. PubMed ID: 15290485
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sitting or tilt position for infant lumbar puncture does not increase ultrasound measurements of lumbar subarachnoid space width.
    Lo MD; Parisi MT; Brown JC; Klein EJ
    Pediatr Emerg Care; 2013 May; 29(5):588-91. PubMed ID: 23603648
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lumbar intersegmental spacing and angulation in the modified lateral decubitus position versus variants of prone positioning.
    Agarwal V; Wildstein M; Tillman JB; Pelkey WL; Alamin TF
    Spine J; 2009 Jul; 9(7):580-4. PubMed ID: 19482515
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Needle-entry angle for lumbar puncture in children as determined by using ultrasonography.
    Bruccoleri RE; Chen L
    Pediatrics; 2011 Apr; 127(4):e921-6. PubMed ID: 21444601
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasound evaluation of lumbar spine anatomy in newborn infants: implications for optimal performance of lumbar puncture.
    Oulego-Erroz I; Mora-Matilla M; Alonso-Quintela P; Rodríguez-Blanco S; Mata-Zubillaga D; de Armentia SL
    J Pediatr; 2014 Oct; 165(4):862-5.e1. PubMed ID: 25063721
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasound identification of landmarks preceding lumbar puncture: a pilot study.
    Ferre RM; Sweeney TW; Strout TD
    Emerg Med J; 2009 Apr; 26(4):276-7. PubMed ID: 19307389
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Seated Position Does Not Change Lumbar Dimensions Compared With Lateral Position.
    Long MT; Del Re AM; Uya A; Kanegaye JT; Nguyen MB
    Pediatr Emerg Care; 2022 Jan; 38(1):e23-e26. PubMed ID: 32925704
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Establishing intercrestal line by posture:--a radiographic evaluation.
    Shiraishi N; Matsumura G
    Okajimas Folia Anat Jpn; 2006 Feb; 82(4):139-46. PubMed ID: 16526572
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of manual palpation vs ultrasound for identifying the L3-L4 intervertebral space level in children.
    Hayes J; Borges B; Armstrong D; Srinivasan I
    Paediatr Anaesth; 2014 May; 24(5):510-5. PubMed ID: 24467629
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bedside ultrasound for difficult lumbar puncture.
    Peterson MA; Abele J
    J Emerg Med; 2005 Feb; 28(2):197-200. PubMed ID: 15707816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Effect of Bedside Ultrasonographic Skin Marking on Infant Lumbar Puncture Success: A Randomized Controlled Trial.
    Neal JT; Kaplan SL; Woodford AL; Desai K; Zorc JJ; Chen AE
    Ann Emerg Med; 2017 May; 69(5):610-619.e1. PubMed ID: 27856020
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Sonographic Appearance of Spinal Fluid at Clinically Selected Interspaces in Sitting Versus Lateral Positions.
    Vitberg YM; Tseng P; Kessler DO
    Pediatr Emerg Care; 2018 May; 34(5):334-338. PubMed ID: 27482967
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasound-assisted lumbar puncture in infants.
    Ayalin T; Lam SH
    Acad Emerg Med; 2011 Apr; 18(4):e36. PubMed ID: 21496132
    [No Abstract]   [Full Text] [Related]  

  • 19. Anatomical landmarks based assessment of intravertebral space level for lumbar puncture is misleading in more than 30%.
    Duniec L; Nowakowski P; Kosson D; Łazowski T
    Anaesthesiol Intensive Ther; 2013; 45(1):1-6. PubMed ID: 23572300
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Recommendations on the Use of Ultrasound Guidance for Adult Lumbar Puncture: A Position Statement of the Society of Hospital Medicine.
    Soni NJ; Franco-Sadud R; Kobaidze K; Schnobrich D; Salame G; Lenchus J; Kalidindi V; Mader MJ; Haro EK; Dancel R; Cho J; Grikis L; ; Lucas BP
    J Hosp Med; 2019 Oct; 14(10):591-601. PubMed ID: 31251163
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.