BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 20406514)

  • 1. In vitro evaluation of an active heat-and-moisture exchanger: the Hygrovent Gold.
    Pelosi P; Severgnini P; Selmo G; Corradini M; Chiaranda M; Novario R; Park GR
    Respir Care; 2010 Apr; 55(4):460-6. PubMed ID: 20406514
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
    Christiansen S; Renzing K; Hirche H; Reidemeister JC
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro and in vivo evaluation of a new active heat moisture exchanger.
    Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M
    Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance.
    Thiéry G; Boyer A; Pigné E; Salah A; De Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):699-704. PubMed ID: 12626972
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
    Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.
    Brusasco C; Corradi F; Vargas M; Bona M; Bruno F; Marsili M; Simonassi F; Santori G; Severgnini P; Kacmarek RM; Pelosi P
    Respir Care; 2013 Nov; 58(11):1878-85. PubMed ID: 23674812
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Humidification assessment of four heat and moisture exchanger filters according to ISO 9360: 2000 standard].
    Lannoy D; Décaudin B; Resibois JP; Barrier F; Wierre L; Horrent S; Batt C; Moulront S; Odou P
    Ann Fr Anesth Reanim; 2008 Feb; 27(2):148-53. PubMed ID: 18164895
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
    Martin C; Papazian L; Perrin G; Saux P; Gouin F
    Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
    Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L
    Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Devices used to humidify respired gases.
    Rathgeber J
    Respir Care Clin N Am; 2006 Jun; 12(2):165-82. PubMed ID: 16828689
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of resistance in 8 different heat-and-moisture exchangers: effects of saturation and flow rate/profile.
    Lucato JJ; Tucci MR; Schettino GP; Adams AB; Fu C; Forti G; de Carvalho CR; de Souza R
    Respir Care; 2005 May; 50(5):636-43. PubMed ID: 15871758
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new device for 100 per cent humidification of inspired air.
    Larsson A; Gustafsson A; Svanborg L
    Crit Care; 2000; 4(1):54-60. PubMed ID: 11056746
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Is reduction of intraoperative heat loss and management of hypothermic patients with anesthetic gas climate control advisable? Heat and humidity exchangers vs. active humidifiers ina functional lung model].
    Rathgeber J; Weyland W; Bettka T; Züchner K; Kettler D
    Anaesthesist; 1996 Sep; 45(9):807-13. PubMed ID: 8967598
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical effects of airway humidification devices in difficult to wean patients.
    Girault C; Breton L; Richard JC; Tamion F; Vandelet P; Aboab J; Leroy J; Bonmarchand G
    Crit Care Med; 2003 May; 31(5):1306-11. PubMed ID: 12771595
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.
    Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D
    Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia.
    Luchetti M; Pigna A; Gentili A; Marraro G
    Paediatr Anaesth; 1999; 9(1):39-45. PubMed ID: 10712714
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation.
    Boisson C; Viviand X; Arnaud S; Thomachot L; Miliani Y; Martin C
    Intensive Care Med; 1999 Nov; 25(11):1237-43. PubMed ID: 10654207
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate.
    Zuur JK; Muller SH; Vincent A; Sinaasappel M; de Jongh FH; Hilgers FJ
    Head Neck; 2008 Aug; 30(8):1072-82. PubMed ID: 18528903
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The temperature and humidity in a low-flow anesthesia workstation with and without a heat and moisture exchanger.
    de Castro J; Bolfi F; de Carvalho LR; Braz JR
    Anesth Analg; 2011 Sep; 113(3):534-8. PubMed ID: 21680862
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of heat and moisture exchanger efficiency.
    Chandler M
    Anaesthesia; 2013 Sep; 68(9):953-60. PubMed ID: 24047355
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.