BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

282 related articles for article (PubMed ID: 20409559)

  • 21. Changes in transcranial motor evoked potentials during intramedullary spinal cord tumor resection correlate with postoperative motor function.
    Quiñones-Hinojosa A; Lyon R; Zada G; Lamborn KR; Gupta N; Parsa AT; McDermott MW; Weinstein PR
    Neurosurgery; 2005 May; 56(5):982-93; discussion 982-93. PubMed ID: 15854246
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intraoperative use of transcranial motor/sensory evoked potential monitoring in the clipping of intracranial aneurysms: evaluation of false-positive and false-negative cases.
    Chung J; Park W; Hong SH; Park JC; Ahn JS; Kwun BD; Lee SA; Kim SH; Jeon JY
    J Neurosurg; 2018 Mar; 130(3):936-948. PubMed ID: 29570008
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of intraoperative monitoring of somatosensory evoked potentials to prevent ischaemic stroke after surgical exclusion of middle cerebral artery aneurysms.
    Penchet G; Arné P; Cuny E; Monteil P; Loiseau H; Castel JP
    Acta Neurochir (Wien); 2007; 149(4):357-64. PubMed ID: 17380251
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effectiveness and Limitations of Intraoperative Monitoring with Combined Motor and Somatosensory Evoked Potentials During Surgical Clipping of Unruptured Intracranial Aneurysms.
    Choi HH; Ha EJ; Cho WS; Kang HS; Kim JE
    World Neurosurg; 2017 Dec; 108():738-747. PubMed ID: 28951267
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Alarm criteria for motor-evoked potentials: what's wrong with the "presence-or-absence" approach?
    Calancie B; Molano MR
    Spine (Phila Pa 1976); 2008 Feb; 33(4):406-14. PubMed ID: 18277873
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Are there false-negative results of motor evoked potential monitoring in brain surgery?
    Neuloh G; Schramm J
    Cent Eur Neurosurg; 2009 Nov; 70(4):171-5. PubMed ID: 19851956
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Bypass or not? Adjustment of surgical strategies according to motor evoked potential changes in large middle cerebral artery aneurysm surgery.
    Chen L; Lang L; Zhou L; Song D; Mao Y
    World Neurosurg; 2012 Feb; 77(2):398.E1-6. PubMed ID: 22501021
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Motor-evoked potentials (MEP) during brainstem surgery to preserve corticospinal function.
    Sarnthein J; Bozinov O; Melone AG; Bertalanffy H
    Acta Neurochir (Wien); 2011 Sep; 153(9):1753-9. PubMed ID: 21660421
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Outcome of surgical clipping of unruptured aneurysms as it compares with a 10-year nonclipping survival period.
    Krisht AF; Gomez J; Partington S
    Neurosurgery; 2006 Feb; 58(2):207-16; discussion 207-16. PubMed ID: 16462473
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Stroke prevention during surgery for deep-seated gliomas.
    Neuloh G; Simon M; Schramm J
    Neurophysiol Clin; 2007 Dec; 37(6):383-9. PubMed ID: 18083493
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Usefulness of Transcranial Motor Evoked Potential in Clipping Surgery for Cerebral Aneurysms-Introduction of a New Protocol for Stable Monitoring.
    Sasaki T; Murakami K; Saito A; Haryu S; Kameyama M; Takahashi Y; Takamuro S; Kato N; Endo T
    Neurol Med Chir (Tokyo); 2023 Sep; 63(9):409-419. PubMed ID: 37380449
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Intraoperative facial motor evoked potential monitoring with transcranial electrical stimulation during skull base surgery.
    Dong CC; Macdonald DB; Akagami R; Westerberg B; Alkhani A; Kanaan I; Hassounah M
    Clin Neurophysiol; 2005 Mar; 116(3):588-96. PubMed ID: 15721072
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The application of tetanic stimulation of the unilateral tibial nerve before transcranial stimulation can augment the amplitudes of myogenic motor-evoked potentials from the muscles in the bilateral upper and lower limbs.
    Hayashi H; Kawaguchi M; Yamamoto Y; Inoue S; Koizumi M; Ueda Y; Takakura Y; Furuya H
    Anesth Analg; 2008 Jul; 107(1):215-20. PubMed ID: 18635490
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of posttetanic motor evoked potentials--the influences of repetitive use, the residual effects of tetanic stimulation to peripheral nerve, and the variability.
    Yamamoto Y; Kawaguchi M; Hayashi H; Abe R; Inoue S; Nakase H; Sakaki T; Furuya H
    J Neurosurg Anesthesiol; 2010 Jan; 22(1):6-10. PubMed ID: 19779367
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Application of intraoperative motor evoked potential monitoring during giant internal carotid artery aneurysm surgery using prolonged temporary occlusion.
    Song J; Lang L; Zhu W; Gu Y; Xu B; Cai J; Yue Q; Xu G; Chen L; Mao Y
    Acta Neurochir (Wien); 2015 Nov; 157(11):1833-40. PubMed ID: 26335757
    [TBL] [Abstract][Full Text] [Related]  

  • 36. False negative and positive motor evoked potentials in one patient: is single motor evoked potential monitoring reliable method? A case report and literature review.
    Hong JY; Suh SW; Modi HN; Hur CY; Song HR; Park JH
    Spine (Phila Pa 1976); 2010 Aug; 35(18):E912-6. PubMed ID: 20956881
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Treatment outcomes of surgical clipping for unruptured anterior circulation aneurysm-single institute experiences in the era of neurophysiologic monitoring and endovascular treatment.
    Jo KI; Kim HR; Yeon JY; Hong SC; Kim JS
    Neurosurg Rev; 2015 Oct; 38(4):677-82. PubMed ID: 25962556
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Four-limb muscle motor evoked potential and optimized somatosensory evoked potential monitoring with decussation assessment: results in 206 thoracolumbar spine surgeries.
    Macdonald DB; Al Zayed Z; Al Saddigi A
    Eur Spine J; 2007 Nov; 16 Suppl 2(Suppl 2):S171-87. PubMed ID: 17638028
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The efficacy of motor evoked potentials in fixed sagittal imbalance deformity correction surgery.
    Lieberman JA; Lyon R; Feiner J; Hu SS; Berven SH
    Spine (Phila Pa 1976); 2008 Jun; 33(13):E414-24. PubMed ID: 18520928
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of low-dose ketamine on voltage requirement for transcranial electrical motor evoked potentials in children.
    Zaarour C; Engelhardt T; Strantzas S; Pehora C; Lewis S; Crawford MW
    Spine (Phila Pa 1976); 2007 Oct; 32(22):E627-30. PubMed ID: 18090070
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.