These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 20421223)

  • 21. A safer way to get hemodynamic data.
    Bucher N
    RN; 1992 Nov; 55(11):56-61. PubMed ID: 1470852
    [No Abstract]   [Full Text] [Related]  

  • 22. Noninvasive monitoring of cardiac output during exercise by inductance cardiography.
    Kaplan V; Bucklar GB; Bloch KE
    Med Sci Sports Exerc; 2003 May; 35(5):747-52. PubMed ID: 12750583
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Mechano- and impedance cardiography parameters in patients with heart failure in administration of a calcium antagonist. The significance of the Heather index].
    Linde M; Ohnhaus EE; Kirch W
    Z Kardiol; 1989 Mar; 78(3):181-6. PubMed ID: 2652906
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Noninvasive monitoring of cardiac output in human neonates and juvenile piglets by inductance cardiography (thoracocardiography).
    Bloch KE; Adams JA; Bassuk JJ; Mangino MJ; Sackner MA
    J Crit Care; 2002 Dec; 17(4):259-66. PubMed ID: 12501155
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Nonhemodynamic parameters from implantable devices for heart failure risk stratification.
    Boehmer JP
    Heart Fail Clin; 2015 Apr; 11(2):191-201. PubMed ID: 25834969
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Noninvasive monitoring of transient cardiac changes with impedance cardiography.
    Zhang H; Li JK
    Cardiovasc Eng; 2008 Dec; 8(4):225-31. PubMed ID: 19130223
    [TBL] [Abstract][Full Text] [Related]  

  • 27. AANA Journal course: new technologies in anesthesia: update for nurse anesthetists--noninvasive, continuous, cardiac output monitoring by thoracic electrical bioimpedance. 16.
    Atkins CS
    AANA J; 1991 Oct; 59(5):445-52. PubMed ID: 1957569
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Comparison of ICG thoracic bioimpedance cardiac output monitoring system in patients undergoing cardiac surgery with pulmonary artery cardiac output measurements].
    Simon R; Desebbe O; Hénaine R; Bastien O; Lehot JJ; Cannesson M
    Ann Fr Anesth Reanim; 2009 Jun; 28(6):537-41. PubMed ID: 19525086
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Trending of impedance-monitored cardiac variables: method and statistical power analysis of 100 control studies in a pediatric intensive care unit.
    Mickell JJ; Lucking SE; Chaten FC; Young ES
    Crit Care Med; 1990 Jun; 18(6):645-50. PubMed ID: 2344756
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Combined active compression-decompression cardiopulmonary resuscitation and inspiratory impedance threshold devices may improve survival after out-of-hospital cardiac arrest.
    Lobodzinski SS
    Cardiol J; 2011; 18(2):207-9. PubMed ID: 21432833
    [No Abstract]   [Full Text] [Related]  

  • 31. Improvement in intracardiac impedance volumes by field extrapolation.
    Salo RW
    Eur Heart J; 1992 Nov; 13 Suppl E():35-9. PubMed ID: 1478207
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Computer method for automatic determination of stroke volume using impedance cardiography signals.
    Cybulski G
    Acta Physiol Pol; 1988; 39(5-6):494-503. PubMed ID: 3257063
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cardiac output by impedance cardiography during head-out water immersion.
    Shiraki K; Konda N; Sagawa S; Lin YC; Hong SK
    Undersea Biomed Res; 1986 Jun; 13(2):247-56. PubMed ID: 3727186
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Noninvasive assessment of hemodynamics: an emphasis on bioimpedance cardiography.
    Rosenberg P; Yancy CW
    Curr Opin Cardiol; 2000 May; 15(3):151-5. PubMed ID: 10952420
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Impedance cardiography - a modern tool for monitoring therapy of cardiovascular diseases].
    Krzesiński P; Gielerak G; Kowal J
    Kardiol Pol; 2009 Jan; 67(1):65-71. PubMed ID: 19253194
    [No Abstract]   [Full Text] [Related]  

  • 36. Descending aortic flow contribution to intrathoracic impedance-development and preliminary testing of a dual impedance model.
    Baker AB; McLeod CN; Roxburgh AJ; Bannister P
    J Clin Monit Comput; 2008 Feb; 22(1):11-22. PubMed ID: 18004667
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Impedance cardiography: non-invasive cardiac output measurement after burn injury.
    Griffths RW; Philpot ME; Chapman BJ; Munday KA
    Int J Tissue React; 1981 Mar; 3(1):47-55. PubMed ID: 7287057
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Noninvasive ventilatory volume monitor using the electrical impedance method--elimination of impedance changes associated with cardiac oscillations].
    Itoh A; Kikuchi N; Ishida A; Okazaki N; Kira S
    Iyodenshi To Seitai Kogaku; 1982 Sep; 20(5):314-20. PubMed ID: 7182614
    [No Abstract]   [Full Text] [Related]  

  • 39. Computer supported analysis of cardiovascular parameters by impedance cardiography and plethysmography.
    Hunold S; Hexamer M; Werner J; Gehrt M
    Med Prog Technol; 1993; 19(2):105-13. PubMed ID: 8107666
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Noninvasive measurement of cardiac output during laparoscopy.
    McKenzie R; Wadhwa RK; Bedger RC
    J Reprod Med; 1980 Jun; 24(6):247-50. PubMed ID: 6448295
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.