These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
254 related articles for article (PubMed ID: 20430460)
1. A study on the dosimetric accuracy of treatment planning for stereotactic body radiation therapy of lung cancer using average and maximum intensity projection images. Huang L; Park K; Boike T; Lee P; Papiez L; Solberg T; Ding C; Timmerman RD Radiother Oncol; 2010 Jul; 96(1):48-54. PubMed ID: 20430460 [TBL] [Abstract][Full Text] [Related]
2. The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy. Clements N; Kron T; Franich R; Dunn L; Roxby P; Aarons Y; Chesson B; Siva S; Duplan D; Ball D Med Phys; 2013 Feb; 40(2):021904. PubMed ID: 23387752 [TBL] [Abstract][Full Text] [Related]
3. Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage. Wang L; Hayes S; Paskalev K; Jin L; Buyyounouski MK; Ma CC; Feigenberg S Radiother Oncol; 2009 Jun; 91(3):314-24. PubMed ID: 19111362 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images. Wang L; Chen X; Lin MH; Xue J; Lin T; Fan J; Jin L; Ma CM Med Phys; 2013 Nov; 40(11):111709. PubMed ID: 24320417 [TBL] [Abstract][Full Text] [Related]
5. Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT. Liu G; Hu F; Ding X; Li X; Shao Q; Wang Y; Yang J; Quan H Radiat Oncol; 2019 Jan; 14(1):1. PubMed ID: 30621744 [TBL] [Abstract][Full Text] [Related]
6. 3D delivered dose assessment using a 4DCT-based motion model. Cai W; Hurwitz MH; Williams CL; Dhou S; Berbeco RI; Seco J; Mishra P; Lewis JH Med Phys; 2015 Jun; 42(6):2897-907. PubMed ID: 26127043 [TBL] [Abstract][Full Text] [Related]
7. Do maximum intensity projection images truly capture tumor motion? Park K; Huang L; Gagne H; Papiez L Int J Radiat Oncol Biol Phys; 2009 Feb; 73(2):618-25. PubMed ID: 19147026 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy. Oechsner M; Odersky L; Berndt J; Combs SE; Wilkens JJ; Duma MN Radiat Oncol; 2015 Dec; 10():249. PubMed ID: 26626865 [TBL] [Abstract][Full Text] [Related]
9. Phantom and clinical study of differences in cone beam computed tomographic registration when aligned to maximum and average intensity projection. Shirai K; Nishiyama K; Katsuda T; Teshima T; Ueda Y; Miyazaki M; Tsujii K Int J Radiat Oncol Biol Phys; 2014 Jan; 88(1):189-94. PubMed ID: 24331666 [TBL] [Abstract][Full Text] [Related]
10. On the validity of density overrides for VMAT lung SBRT planning. Wiant D; Vanderstraeten C; Maurer J; Pursley J; Terrell J; Sintay BJ Med Phys; 2014 Aug; 41(8):081707. PubMed ID: 25086517 [TBL] [Abstract][Full Text] [Related]
12. The irregular breathing effect on target volume and coverage for lung stereotactic body radiotherapy. Pan CH; Shiau AC; Li KC; Hsu SH; Liang JA J Appl Clin Med Phys; 2019 Jul; 20(7):109-120. PubMed ID: 31207034 [TBL] [Abstract][Full Text] [Related]
13. Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy. Freislederer P; von Münchow A; Kamp F; Heinz C; Gerum S; Corradini S; Söhn M; Reiner M; Roeder F; Floca R; Alber M; Belka C; Parodi K Med Phys; 2019 Jul; 46(7):3268-3277. PubMed ID: 31074510 [TBL] [Abstract][Full Text] [Related]
14. Technical and dosimetric implications of respiratory induced density variations in a heterogeneous lung phantom. Mohatt DJ; Ma T; Wiant DB; Islam NM; Gomez J; Singh AK; Malhotra HK Radiat Oncol; 2018 Sep; 13(1):165. PubMed ID: 30180894 [TBL] [Abstract][Full Text] [Related]
15. Comparing phase- and amplitude-gated volumetric modulated arc therapy for stereotactic body radiation therapy using 3D printed lung phantom. Lee M; Yoon K; Cho B; Kim SS; Song SY; Choi EK; Ahn S; Lee SW; Kwak J J Appl Clin Med Phys; 2019 Feb; 20(2):107-113. PubMed ID: 30667581 [TBL] [Abstract][Full Text] [Related]
16. Dosimetric comparison of treatment plans based on free breathing, maximum, and average intensity projection CTs for lung cancer SBRT. Tian Y; Wang Z; Ge H; Zhang T; Cai J; Kelsey C; Yoo D; Yin FF Med Phys; 2012 May; 39(5):2754-60. PubMed ID: 22559646 [TBL] [Abstract][Full Text] [Related]
17. Correction for 'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung. Disher B; Hajdok G; Wang A; Craig J; Gaede S; Battista JJ Phys Med Biol; 2013 Jun; 58(12):4157-74. PubMed ID: 23689060 [TBL] [Abstract][Full Text] [Related]
18. Variations of target volume definition and daily target volume localization in stereotactic body radiotherapy for early-stage non-small cell lung cancer patients under abdominal compression. Han C; Sampath S; Schultheisss TE; Wong JYC Med Dosim; 2017 Summer; 42(2):116-121. PubMed ID: 28433482 [TBL] [Abstract][Full Text] [Related]
19. Dosimetric impact of breathing motion in lung stereotactic body radiotherapy treatment using intensity modulated radiotherapy and volumetric modulated arc therapy [corrected]. Rao M; Wu J; Cao D; Wong T; Mehta V; Shepard D; Ye J Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):e251-6. PubMed ID: 22365622 [TBL] [Abstract][Full Text] [Related]
20. Effects of reconstruction methods on dose distribution for lung stereotactic body radiotherapy treatment plans. Yedekci Y; Hurmuz P; Ozyigit G Radiat Environ Biophys; 2023 Mar; 62(1):107-115. PubMed ID: 36526911 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]