82 related articles for article (PubMed ID: 20434386)
1. [Statistical process control applied to intensity modulated radiotherapy pretreatment controls with portal dosimetry].
Villani N; Gérard K; Marchesi V; Huger S; François P; Noël A
Cancer Radiother; 2010 Jun; 14(3):189-97. PubMed ID: 20434386
[TBL] [Abstract][Full Text] [Related]
2. Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy.
Lee EK; Fox T; Crocker I
Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):301-20. PubMed ID: 16289912
[TBL] [Abstract][Full Text] [Related]
3. Fast, daily linac verification for segmented IMRT using electronic portal imaging.
Vieira SC; Bolt RA; Dirkx ML; Visser AG; Heijmen BJ
Radiother Oncol; 2006 Jul; 80(1):86-92. PubMed ID: 16854483
[TBL] [Abstract][Full Text] [Related]
4. Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT.
McDermott LN; Wendling M; Sonke JJ; van Herk M; Mijnheer BJ
Int J Radiat Oncol Biol Phys; 2007 Apr; 67(5):1568-77. PubMed ID: 17394951
[TBL] [Abstract][Full Text] [Related]
5. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
Baker SJ; Budgell GJ; MacKay RI
Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
[TBL] [Abstract][Full Text] [Related]
6. Uncertainty estimation in intensity-modulated radiotherapy absolute dosimetry verification.
Sánchez-Doblado F; Hartmann GH; Pena J; Capote R; Paiusco M; Rhein B; Leal A; Lagares JI
Int J Radiat Oncol Biol Phys; 2007 May; 68(1):301-10. PubMed ID: 17448883
[TBL] [Abstract][Full Text] [Related]
7. A literature review of electronic portal imaging for radiotherapy dosimetry.
van Elmpt W; McDermott L; Nijsten S; Wendling M; Lambin P; Mijnheer B
Radiother Oncol; 2008 Sep; 88(3):289-309. PubMed ID: 18706727
[TBL] [Abstract][Full Text] [Related]
8. Process control analysis of IMRT QA: implications for clinical trials.
Pawlicki T; Yoo S; Court LE; McMillan SK; Rice RK; Russell JD; Pacyniak JM; Woo MK; Basran PS; Boyer AL; Bonilla C
Phys Med Biol; 2008 Sep; 53(18):5193-205. PubMed ID: 18728311
[TBL] [Abstract][Full Text] [Related]
9. Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors.
Sánchez-Doblado F; Capote R; Leal A; Roselló JV; Lagares JI; Arráns R; Hartmann GH
Phys Med Biol; 2005 Mar; 50(5):959-70. PubMed ID: 15798268
[TBL] [Abstract][Full Text] [Related]
10. 3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID.
van Zijtveld M; Dirkx ML; de Boer HC; Heijmen BJ
Radiother Oncol; 2007 Feb; 82(2):201-7. PubMed ID: 17287039
[TBL] [Abstract][Full Text] [Related]
11. Volumetric modulated arc therapy: planning and evaluation for prostate cancer cases.
Zhang P; Happersett L; Hunt M; Jackson A; Zelefsky M; Mageras G
Int J Radiat Oncol Biol Phys; 2010 Apr; 76(5):1456-62. PubMed ID: 19540062
[TBL] [Abstract][Full Text] [Related]
12. 3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry.
Mans A; Remeijer P; Olaciregui-Ruiz I; Wendling M; Sonke JJ; Mijnheer B; van Herk M; Stroom JC
Radiother Oncol; 2010 Feb; 94(2):181-7. PubMed ID: 20089323
[TBL] [Abstract][Full Text] [Related]
13. [Application of amorphous silicon electronic portal imaging device (a-Si EPID) to dosimetry quality assurance of radiation therapy].
Chen MW; Deng XW; Huang SM; Chen L; Kang DH
Ai Zheng; 2007 Nov; 26(11):1272-5. PubMed ID: 17991332
[TBL] [Abstract][Full Text] [Related]
14. Moving from IMRT QA measurements toward independent computer calculations using control charts.
Pawlicki T; Yoo S; Court LE; McMillan SK; Rice RK; Russell JD; Pacyniak JM; Woo MK; Basran PS; Shoales J; Boyer AL
Radiother Oncol; 2008 Dec; 89(3):330-7. PubMed ID: 18701175
[TBL] [Abstract][Full Text] [Related]
15. Intensity- and energy-modulated electron radiotherapy by means of an xMLC for head and neck shallow tumors.
Salguero FJ; Arráns R; Palma BA; Leal A
Phys Med Biol; 2010 Mar; 55(5):1413-27. PubMed ID: 20150682
[TBL] [Abstract][Full Text] [Related]
16. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC).
Gérard K; Grandhaye JP; Marchesi V; Kafrouni H; Husson F; Aletti P
Med Phys; 2009 Apr; 36(4):1275-85. PubMed ID: 19472636
[TBL] [Abstract][Full Text] [Related]
17. Direct-detection EPID dosimetry: investigation of a potential clinical configuration for IMRT verification.
Vial P; Gustafsson H; Oliver L; Baldock C; Greer PB
Phys Med Biol; 2009 Dec; 54(23):7151-69. PubMed ID: 19904032
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach.
Wiezorek T; Banz N; Schwedas M; Scheithauer M; Salz H; Georg D; Wendt TG
Strahlenther Onkol; 2005 Jul; 181(7):468-74. PubMed ID: 15995841
[TBL] [Abstract][Full Text] [Related]
19. A practical Monte Carlo MU verification tool for IMRT quality assurance.
Fan J; Li J; Chen L; Stathakis S; Luo W; Du Plessis F; Xiong W; Yang J; Ma CM
Phys Med Biol; 2006 May; 51(10):2503-15. PubMed ID: 16675866
[TBL] [Abstract][Full Text] [Related]
20. Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT.
Grigorov GN; Chow JC; Barnett RB
Phys Med Biol; 2006 Feb; 51(3):637-52. PubMed ID: 16424586
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]