These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
138 related articles for article (PubMed ID: 20436988)
21. Evaluation of keratometric, pachymetric, and elevation parameters of keratoconic corneas with pentacam. Miháltz K; Kovács I; Takács A; Nagy ZZ Cornea; 2009 Oct; 28(9):976-80. PubMed ID: 19724217 [TBL] [Abstract][Full Text] [Related]
22. Corneal thickness, curvature, and elevation readings in normal corneas: combined Placido-Scheimpflug system versus combined Placido-scanning-slit system. Guilbert E; Saad A; Grise-Dulac A; Gatinel D J Cataract Refract Surg; 2012 Jul; 38(7):1198-206. PubMed ID: 22727289 [TBL] [Abstract][Full Text] [Related]
23. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. Shankar H; Taranath D; Santhirathelagan CT; Pesudovs K J Cataract Refract Surg; 2008 Jan; 34(1):103-13. PubMed ID: 18165089 [TBL] [Abstract][Full Text] [Related]
24. Corneal differences between healthy and subclinical patients assessed using two diferente corneal tomographers. Zhao H; Yang Z; Han X; Guan W; Wang Z; Cai M; Sun Y; Ge R; Wang R Arq Bras Oftalmol; 2020; 83(2):92-97. PubMed ID: 31778445 [TBL] [Abstract][Full Text] [Related]
25. Pentacam and Orbscan II measurements of posterior corneal elevation before and after photorefractive keratectomy. Ha BJ; Kim SW; Kim SW; Kim EK; Kim TI J Refract Surg; 2009 Mar; 25(3):290-5. PubMed ID: 19370825 [TBL] [Abstract][Full Text] [Related]
26. Repeatability and agreement of three Scheimpflug-based imaging systems for measuring anterior segment parameters in keratoconus. Shetty R; Arora V; Jayadev C; Nuijts RM; Kumar M; Puttaiah NK; Kummelil MK Invest Ophthalmol Vis Sci; 2014 Jul; 55(8):5263-8. PubMed ID: 25074774 [TBL] [Abstract][Full Text] [Related]
27. Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement. Kawamorita T; Uozato H; Kamiya K; Bax L; Tsutsui K; Aizawa D; Shimizu K J Cataract Refract Surg; 2009 Jan; 35(1):127-33. PubMed ID: 19101435 [TBL] [Abstract][Full Text] [Related]
28. Reliability of Orbscan II topography measurements in relation to refractive status. Rabsilber TM; Becker KA; Auffarth GU J Cataract Refract Surg; 2005 Aug; 31(8):1607-13. PubMed ID: 16129300 [TBL] [Abstract][Full Text] [Related]
29. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices. Shetty R; Agrawal A; Deshmukh R; Kaweri L; Rao HL; Nagaraja H; Jayadev C Indian J Ophthalmol; 2017 Apr; 65(4):305-310. PubMed ID: 28513495 [TBL] [Abstract][Full Text] [Related]
30. Comparison of three methods of measuring corneal thickness and anterior chamber depth. Buehl W; Stojanac D; Sacu S; Drexler W; Findl O Am J Ophthalmol; 2006 Jan; 141(1):7-12. PubMed ID: 16386970 [TBL] [Abstract][Full Text] [Related]
32. Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye. Chen D; Lam AK J Cataract Refract Surg; 2007 Mar; 33(3):448-54. PubMed ID: 17321396 [TBL] [Abstract][Full Text] [Related]
33. Repeatability and reproducibility of Galilei measurements in normal keratoconic and postrefractive corneas. Güler E; Yağci R; Akyol M; Arslanyılmaz Z; Balci M; Hepşen IF Cont Lens Anterior Eye; 2014 Oct; 37(5):331-6. PubMed ID: 24938125 [TBL] [Abstract][Full Text] [Related]
34. Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam. Mirzajani A; Asharlous A; Kianpoor P; Jafarzadehpur E; Yekta A; Khabazkhoob M; Hashemi H J Curr Ophthalmol; 2019 Dec; 31(4):382-386. PubMed ID: 31844787 [TBL] [Abstract][Full Text] [Related]
35. Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus. de Sanctis U; Loiacono C; Richiardi L; Turco D; Mutani B; Grignolo FM Ophthalmology; 2008 Sep; 115(9):1534-9. PubMed ID: 18405974 [TBL] [Abstract][Full Text] [Related]
36. Angle κ and its effect on the corneal elevation maps in refractive surgery candidates. Salouti R; Nowroozzadeh MH; Azizi A; Salouti K; Ghoreyshi M; Oboodi R; Tajbakhsh Z J Cataract Refract Surg; 2022 Oct; 48(10):1148-1154. PubMed ID: 35404317 [TBL] [Abstract][Full Text] [Related]
37. Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery. Rao SN; Raviv T; Majmudar PA; Epstein RJ Ophthalmology; 2002 Sep; 109(9):1642-6. PubMed ID: 12208710 [TBL] [Abstract][Full Text] [Related]
38. Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography. Li EY; Mohamed S; Leung CK; Rao SK; Cheng AC; Cheung CY; Lam DS Ophthalmology; 2007 Oct; 114(10):1842-7. PubMed ID: 17507097 [TBL] [Abstract][Full Text] [Related]
39. Corneal thickness measurements with Scheimpflug and slit scanning imaging techniques in keratoconus. Aghazadeh Amiri M; Hashemi H; Ramin S; Yekta A; Taheri A; Nabovati P; Khabazkhoob M J Curr Ophthalmol; 2017 Mar; 29(1):23-27. PubMed ID: 28367522 [TBL] [Abstract][Full Text] [Related]