314 related articles for article (PubMed ID: 20441472)
21. Evaluation of ADVIA 120 CSF assay (Bayer) vs. chamber counting of cerebrospinal fluid specimens.
Mahieu S; Vertessen F; Van der Planken M
Clin Lab Haematol; 2004 Jun; 26(3):195-9. PubMed ID: 15163317
[TBL] [Abstract][Full Text] [Related]
22. Evaluation of biological fluid analysis using the sysmex XN automatic hematology analyzer.
Aguadero V; Cano-Corres R; Berlanga E; Torra M
Cytometry B Clin Cytom; 2018 Sep; 94(5):680-688. PubMed ID: 28834596
[TBL] [Abstract][Full Text] [Related]
23. Automated cerebrospinal fluid cytology.
Heller T; Nagel I; Ehrlich B; Bähr M; Strik H
Anal Quant Cytol Histol; 2008 Jun; 30(3):139-44. PubMed ID: 18630838
[TBL] [Abstract][Full Text] [Related]
24. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.
Kawai Y; Nagai Y; Ogawa E; Kondo H
Int J Lab Hematol; 2017 Apr; 39(2):202-222. PubMed ID: 28013527
[TBL] [Abstract][Full Text] [Related]
25. Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness.
Kang SH; Kim HK; Ham CK; Lee DS; Cho HI
Int J Lab Hematol; 2008 Dec; 30(6):480-6. PubMed ID: 19062362
[TBL] [Abstract][Full Text] [Related]
26. Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i.
Buoro S; Apassiti Esposito S; Alessio M; Crippa A; Ottomano C; Lippi G
J Clin Lab Anal; 2016 Sep; 30(5):381-91. PubMed ID: 26302990
[TBL] [Abstract][Full Text] [Related]
27. [New leukocyte counting method of cerebrospinal fluid: using transparent ruler tape].
Ryu SW; Suh IB
Korean J Lab Med; 2007 Dec; 27(6):394-9. PubMed ID: 18160828
[TBL] [Abstract][Full Text] [Related]
28. Precision and accuracy of monocyte counting. Comparison of two hematology analyzers, the manual differential and flow cytometry.
Hübl W; Hauptlorenz S; Tlustos L; Jilch R; Fischer M; Bayer PM
Am J Clin Pathol; 1995 Feb; 103(2):167-70. PubMed ID: 7531938
[TBL] [Abstract][Full Text] [Related]
29. Automated counting of cells in cerebrospinal fluid using the CellDyn-4000 haematology analyser.
Hoffmann JJ; Janssen WC
Clin Chem Lab Med; 2002 Nov; 40(11):1168-73. PubMed ID: 12521237
[TBL] [Abstract][Full Text] [Related]
30. Performance evaluation of the Sysmex XE-5000 hematology analyzer for white blood cell analysis in cerebrospinal fluid.
Perné A; Hainfellner JA; Womastek I; Haushofer A; Szekeres T; Schwarzinger I
Arch Pathol Lab Med; 2012 Feb; 136(2):194-8. PubMed ID: 22288968
[TBL] [Abstract][Full Text] [Related]
31. Evaluation of the monocyte counting by two automated haematology analysers compared with flow cytometry.
Grimaldi E; Carandente P; Scopacasa F; Romano MF; Pellegrino M; Bisogni R; De Caterina M
Clin Lab Haematol; 2005 Apr; 27(2):91-7. PubMed ID: 15784123
[TBL] [Abstract][Full Text] [Related]
32. Determination of leukocyte counts in cerebrospinal fluid with a disposable plastic hemocytometer.
Yamanishi H; Imai N; Suehisa E; Kanakura Y; Iwatani Y
J Clin Lab Anal; 2007; 21(5):282-5. PubMed ID: 17847111
[TBL] [Abstract][Full Text] [Related]
33. Improved software on the Sysmex XE-5000 BF mode for counting leukocytes in cerebrospinal fluid.
Fleming C; Brouwer R; Lindemans J; de Jonge R
Clin Chem Lab Med; 2013 Apr; 51(4):e61-3. PubMed ID: 23037515
[No Abstract] [Full Text] [Related]
34. Differential leukocyte counting and immunophenotyping in cryopreserved ex vivo whole blood.
Nemes E; Kagina BM; Smit E; Africa H; Steyn M; Hanekom WA; Scriba TJ
Cytometry A; 2015 Feb; 87(2):157-65. PubMed ID: 25515205
[TBL] [Abstract][Full Text] [Related]
35. Urine flow cytometer quantification of leukocytes in samples containing a large proportion of lymphocytes.
Yamanishi H; Imai N; Ohmine T; Nishiyama M; Suehisa E; Kanakura Y; Iwatani Y
Clin Biochem; 2006 Aug; 39(8):857-9. PubMed ID: 16828730
[TBL] [Abstract][Full Text] [Related]
36. An evaluation of the utility of performing body fluid counts on the coulter LH 750.
Barnes PW; Eby CS; Shimer G
Lab Hematol; 2004; 10(3):127-31. PubMed ID: 15479646
[TBL] [Abstract][Full Text] [Related]
37. Flow cytometric characterization of cerebrospinal fluid cells.
de Graaf MT; de Jongste AH; Kraan J; Boonstra JG; Sillevis Smitt PA; Gratama JW
Cytometry B Clin Cytom; 2011 Sep; 80(5):271-81. PubMed ID: 21567940
[TBL] [Abstract][Full Text] [Related]
38. Stability of canine and feline cerebrospinal fluid samples regarding total cell count and cell populations stored in "TransFix®/EDTA CSF sample storage tubes".
Meier L; Carlson R; Neßler J; Tipold A
BMC Vet Res; 2020 Dec; 16(1):487. PubMed ID: 33334339
[TBL] [Abstract][Full Text] [Related]
39. Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.
Hod EA; Brugnara C; Pilichowska M; Sandhaus LM; Luu HS; Forest SK; Netterwald JC; Reynafarje GM; Kratz A
Int J Lab Hematol; 2018 Feb; 40(1):56-65. PubMed ID: 28880455
[TBL] [Abstract][Full Text] [Related]
40. European multi-center evaluation of the Abbott Cell-Dyn sapphire hematology analyzer.
Müller R; Mellors I; Johannessen B; Aarsand AK; Kiefer P; Hardy J; Kendall R; Scott CS
Lab Hematol; 2006; 12(1):15-31. PubMed ID: 16513543
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]