These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
459 related articles for article (PubMed ID: 20444248)
1. The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study. Wilson BJ; Cowan HJ; Lord JA; Zuege DJ; Zygun DA BMC Emerg Med; 2010 May; 10():9. PubMed ID: 20444248 [TBL] [Abstract][Full Text] [Related]
2. Comparative Analysis of Oxygen Saturation by Pulse Oximetry and Arterial Blood Gas in Hypoxemic Patients in a Tertiary Care Hospital. Abraham EA; Verma G; Arafat Y; Acharya S; Kumar S; Pantbalekundri N Cureus; 2023 Jul; 15(7):e42447. PubMed ID: 37637606 [TBL] [Abstract][Full Text] [Related]
3. Accuracy of pulse oximetry in the intensive care unit. Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension. Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517 [TBL] [Abstract][Full Text] [Related]
5. Facing SpO Thijssen M; Janssen L; le Noble J; Foudraine N J Clin Monit Comput; 2020 Aug; 34(4):693-698. PubMed ID: 31392655 [TBL] [Abstract][Full Text] [Related]
6. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia. Feiner JR; Bickler PE; Mannheimer PD Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731 [TBL] [Abstract][Full Text] [Related]
7. Study of Oxygen Saturation by Pulse Oximetry and Arterial Blood Gas in ICU Patients: A Descriptive Cross-sectional Study. Rauniyar N; Pujari S; Shrestha P JNMA J Nepal Med Assoc; 2020 Oct; 58(230):789-793. PubMed ID: 34504355 [TBL] [Abstract][Full Text] [Related]
8. The accuracy of pulse oximetry in the emergency department. Lee WW; Mayberry K; Crapo R; Jensen RL Am J Emerg Med; 2000 Jul; 18(4):427-31. PubMed ID: 10919532 [TBL] [Abstract][Full Text] [Related]
9. Comparison of oxygen saturation by pulse oximetry and co-oximetry during exercise testing in patients with COPD. McGovern JP; Sasse SA; Stansbury DW; Causing LA; Light RW Chest; 1996 May; 109(5):1151-5. PubMed ID: 8625659 [TBL] [Abstract][Full Text] [Related]
10. A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients. Ebmeier SJ; Barker M; Bacon M; Beasley RC; Bellomo R; Knee Chong C; Eastwood GM; Gilchrist J; Kagaya H; Pilcher J; Reddy SK; Ridgeon E; Sarma N; Sprogis S; Tanaka A; Tweedie M; Weatherall M; Young PJ Anaesth Intensive Care; 2018 May; 46(3):297-303. PubMed ID: 29716488 [TBL] [Abstract][Full Text] [Related]
11. [Accuracy of a pulse oximeter during hypoxia]. Tachibana C; Fukada T; Hasegawa R; Satoh K; Furuya Y; Ohe Y Masui; 1996 Apr; 45(4):479-82. PubMed ID: 8725606 [TBL] [Abstract][Full Text] [Related]
12. Accuracy of pulse oximetry in children. Ross PA; Newth CJ; Khemani RG Pediatrics; 2014 Jan; 133(1):22-9. PubMed ID: 24344108 [TBL] [Abstract][Full Text] [Related]
13. A multicentre prospective observational study comparing arterial blood gas values to those obtained by pulse oximeters used in adult patients attending Australian and New Zealand hospitals. Pilcher J; Ploen L; McKinstry S; Bardsley G; Chien J; Howard L; Lee S; Beckert L; Swanney M; Weatherall M; Beasley R BMC Pulm Med; 2020 Jan; 20(1):7. PubMed ID: 31918697 [TBL] [Abstract][Full Text] [Related]
14. Clinical Outcomes Associated With Overestimation of Oxygen Saturation by Pulse Oximetry in Patients Hospitalized With COVID-19. Fawzy A; Wu TD; Wang K; Sands KE; Fisher AM; Arnold Egloff SA; DellaVolpe JD; Iwashyna TJ; Xu Y; Garibaldi BT JAMA Netw Open; 2023 Aug; 6(8):e2330856. PubMed ID: 37615985 [TBL] [Abstract][Full Text] [Related]
15. Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation? Perkins GD; McAuley DF; Giles S; Routledge H; Gao F Crit Care; 2003 Aug; 7(4):R67. PubMed ID: 12930558 [TBL] [Abstract][Full Text] [Related]
16. Pulse Oximetry: 2023 Year in Review. Hess DR Respir Care; 2024 Jul; 69(8):1033-1041. PubMed ID: 38806220 [TBL] [Abstract][Full Text] [Related]
17. An evaluation of pulse oximetry in prehospital care. Aughey K; Hess D; Eitel D; Bleecher K; Cooley M; Ogden C; Sabulsky N Ann Emerg Med; 1991 Aug; 20(8):887-91. PubMed ID: 1854074 [TBL] [Abstract][Full Text] [Related]
18. Accuracy of the Masimo SET® LNCS neo peripheral pulse oximeter in cyanotic congenital heart disease. Griksaitis MJ; Scrimgeour GE; Pappachan JV; Baldock AJ Cardiol Young; 2016 Aug; 26(6):1183-6. PubMed ID: 26471067 [TBL] [Abstract][Full Text] [Related]
19. Working accuracy of pulse oximetry in COVID-19 patients stepping down from intensive care: a clinical evaluation. Philip KEJ; Bennett B; Fuller S; Lonergan B; McFadyen C; Burns J; Tidswell R; Vlachou A BMJ Open Respir Res; 2020 Dec; 7(1):. PubMed ID: 33361436 [TBL] [Abstract][Full Text] [Related]