BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 20450462)

  • 1. Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients.
    Ståhlberg M; Damgaard M; Ersgård D; Norsk P; Karamanoglu M; Linde C; Braunschweig F
    Scand Cardiovasc J; 2010 Aug; 44(4):201-8. PubMed ID: 20450462
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The reliability of noninvasive cardiac output measurement using the inert gas rebreathing method in patients with advanced heart failure.
    Sobański P; Sinkiewicz W; Kubica J; Błazejewski J; Bujak R
    Cardiol J; 2008; 15(1):63-70. PubMed ID: 18651387
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Peak cardiac power output, measured noninvasively, is a powerful predictor of outcome in chronic heart failure.
    Lang CC; Karlin P; Haythe J; Lim TK; Mancini DM
    Circ Heart Fail; 2009 Jan; 2(1):33-8. PubMed ID: 19808313
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous monitoring of intrathoracic impedance and right ventricular pressures in patients with heart failure.
    Vanderheyden M; Houben R; Verstreken S; Ståhlberg M; Reiters P; Kessels R; Braunschweig F
    Circ Heart Fail; 2010 May; 3(3):370-7. PubMed ID: 20197559
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous haemodynamic monitoring during exercise in patients with pulmonary hypertension.
    Wonisch M; Fruhwald FM; Maier R; Watzinger N; Hödl R; Kraxner W; Perthold W; Klein WW
    Int J Cardiol; 2005 Jun; 101(3):415-20. PubMed ID: 15907409
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Non-invasive measurements of cardiac output in atrial fibrillation: inert gas rebreathing and impedance cardiography.
    Osbak PS; Henriksen JH; Kofoed KF; Jensen GB
    Scand J Clin Lab Invest; 2011 Jul; 71(4):304-13. PubMed ID: 21391778
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physiology of the native heart and Thermo Cardiosystems left ventricular assist device complex at rest and during exercise: implications for chronic support.
    Branch KR; Dembitsky WP; Peterson KL; Adamson R; Gordon JB; Smith SC; Jaski BE
    J Heart Lung Transplant; 1994; 13(4):641-50; discussion 651. PubMed ID: 7947881
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: results of a 1 year multicentre feasibility study.
    Ohlsson A; Kubo SH; Steinhaus D; Connelly DT; Adler S; Bitkover C; Nordlander R; Rydén L; Bennett T
    Eur Heart J; 2001 Jun; 22(11):942-54. PubMed ID: 11428818
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Estimation of cardiac output in patients with congestive heart failure by analysis of right ventricular pressure waveforms.
    Karamanoglu M; Bennett T; Ståhlberg M; Splett V; Kjellström B; Linde C; Braunschweig F
    Biomed Eng Online; 2011 May; 10():36. PubMed ID: 21569499
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter, 12-month follow-up study of patients with chronic heart failure.
    Magalski A; Adamson P; Gadler F; Böehm M; Steinhaus D; Reynolds D; Vlach K; Linde C; Cremers B; Sparks B; Bennett T
    J Card Fail; 2002 Apr; 8(2):63-70. PubMed ID: 12016628
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acute haemodynamic effects of increase in paced heart rate in heart failure patients recorded with an implantable haemodynamic monitor.
    Ståhlberg M; Kessels R; Linde C; Braunschweig F
    Europace; 2011 Feb; 13(2):237-43. PubMed ID: 20952424
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac output response to changes of the atrioventricular delay in different body positions and during exercise in patients receiving cardiac resynchronization therapy.
    Ståhlberg M; Damgaard M; Norsk P; Gabrielsen A; Sahlén A; Linde C; Braunschweig F
    Europace; 2009 Sep; 11(9):1160-7. PubMed ID: 19578177
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Mechano- and impedance cardiography parameters in patients with heart failure in administration of a calcium antagonist. The significance of the Heather index].
    Linde M; Ohnhaus EE; Kirch W
    Z Kardiol; 1989 Mar; 78(3):181-6. PubMed ID: 2652906
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ease of noninvasive measurement of cardiac output coupled with peak VO2 determination at rest and during exercise in patients with heart failure.
    Lang CC; Karlin P; Haythe J; Tsao L; Mancini DM
    Am J Cardiol; 2007 Feb; 99(3):404-5. PubMed ID: 17261407
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography.
    Fellahi JL; Caille V; Charron C; Deschamps-Berger PH; Vieillard-Baron A
    Anesth Analg; 2009 May; 108(5):1553-9. PubMed ID: 19372335
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Changes in right ventricular pressures between hemodialysis sessions recorded by an implantable hemodynamic monitor.
    Kjellström B; Braunschweig F; Löfberg E; Fux T; Grandjean PA; Linde C
    Am J Cardiol; 2009 Jan; 103(1):119-23. PubMed ID: 19101241
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration.
    Maines M; Catanzariti D; Cirrincione C; Valsecchi S; Comisso J; Vergara G
    Europace; 2010 May; 12(5):680-5. PubMed ID: 20047927
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of a radiofrequency-based wireless pressure sensor to swan-ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure.
    Verdejo HE; Castro PF; Concepción R; Ferrada MA; Alfaro MA; Alcaíno ME; Deck CC; Bourge RC
    J Am Coll Cardiol; 2007 Dec; 50(25):2375-82. PubMed ID: 18154961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impedance cardiography: a potential monitor for hemodialysis.
    Wynne JL; Ovadje LO; Akridge CM; Sheppard SW; Vogel RL; Van de Water JM
    J Surg Res; 2006 Jun; 133(1):55-60. PubMed ID: 16631198
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamic changes in right ventricular pressures during haemodialysis recorded with an implantable haemodynamic monitor.
    Braunschweig F; Kjellström B; Söderhäll M; Clyne N; Linde C
    Nephrol Dial Transplant; 2006 Jan; 21(1):176-83. PubMed ID: 16144845
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.