These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

292 related articles for article (PubMed ID: 20450977)

  • 1. Fully automatic stitching and distortion correction of transmission electron microscope images.
    Kaynig V; Fischer B; Müller E; Buhmann JM
    J Struct Biol; 2010 Aug; 171(2):163-73. PubMed ID: 20450977
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of Autostitch for automatic stitching of microscope images.
    Ma B; Zimmermann T; Rohde M; Winkelbach S; He F; Lindenmaier W; Dittmar KE
    Micron; 2007; 38(5):492-9. PubMed ID: 17045805
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automatic distortion correction of endoscopic images captured with wide-angle zoom lens.
    Lee TY; Chang TS; Wei CH; Lai SH; Liu KC; Wu HS
    IEEE Trans Biomed Eng; 2013 Sep; 60(9):2603-13. PubMed ID: 23674408
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fast and accurate marker-based projective registration method for uncalibrated transmission electron microscope tilt series.
    Lee H; Lee J; Shin YG; Lee R; Xing L
    Phys Med Biol; 2010 Jun; 55(12):3417-40. PubMed ID: 20508322
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Distortion Correction and Intensity Inhomogeneity Correction of Glomerulus Transmission Electron Microscope Image].
    Wu Z; Li M; Lu Y; Cao L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2016 Aug; 33(4):755-61. PubMed ID: 29714917
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A toolkit for the characterization of CCD cameras for transmission electron microscopy.
    Vulovic M; Rieger B; van Vliet LJ; Koster AJ; Ravelli RB
    Acta Crystallogr D Biol Crystallogr; 2010 Jan; 66(Pt 1):97-109. PubMed ID: 20057054
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Multiple transmission electron microscopic image stitching based on sift features].
    Li M; Lu Y; Han S; Wu Z; Chen J; Liu Z; Cao L
    Nan Fang Yi Ke Da Xue Xue Bao; 2015 Aug; 35(9):1251-7. PubMed ID: 26403733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of geometric distortion in 0.2T MRI on radiotherapy treatment planning of prostate cancer.
    Petersch B; Bogner J; Fransson A; Lorang T; Pötter R
    Radiother Oncol; 2004 Apr; 71(1):55-64. PubMed ID: 15066296
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aberration-corrected microscopy for structural biology applications.
    Ziegler A; Rockel B; Hegerl R; Freitag B; Lücken U; Plitzko JM
    J Microsc; 2009 Jan; 233(1):170-7. PubMed ID: 19196423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radial averages of astigmatic TEM images.
    Fernando KV
    J Struct Biol; 2008 Oct; 164(1):49-59. PubMed ID: 18662790
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Refinement procedure for the image alignment in high-resolution electron tomography.
    Houben L; Bar Sadan M
    Ultramicroscopy; 2011; 111(9-10):1512-20. PubMed ID: 21930024
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A method for fast automated microscope image stitching.
    Yang F; Deng ZS; Fan QH
    Micron; 2013 May; 48():17-25. PubMed ID: 23465523
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improving accuracy of XRII image distortion correction using a new hybrid image processing method: performance assessment.
    Yan S; Nie S; Zheng B
    Med Phys; 2011 Nov; 38(11):5921-32. PubMed ID: 22047357
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulation of transmission electron microscope images of biological specimens.
    Rullgård H; Ofverstedt LG; Masich S; Daneholt B; Oktem O
    J Microsc; 2011 Sep; 243(3):234-56. PubMed ID: 21631500
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multiphase method for automatic alignment of transmission electron microscope images using markers.
    Brandt S; Heikkonen J; Engelhardt P
    J Struct Biol; 2001 Jan; 133(1):10-22. PubMed ID: 11356060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bright-field scanning confocal electron microscopy using a double aberration-corrected transmission electron microscope.
    Wang P; Behan G; Kirkland AI; Nellist PD; Cosgriff EC; D'Alfonso AJ; Morgan AJ; Allen LJ; Hashimoto A; Takeguchi M; Mitsuishi K; Shimojo M
    Ultramicroscopy; 2011 Jun; 111(7):877-86. PubMed ID: 21093152
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High speed method for in situ multispectral image registration.
    Perrine KA; Lamarche BL; Hopkins DF; Budge SE; Opresko LK; Wiley HS; Sowa MB
    Microsc Res Tech; 2007 Apr; 70(4):382-9. PubMed ID: 17262790
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Seamless stitching of tile scan microscope images.
    Legesse FB; Chernavskaia O; Heuke S; Bocklitz T; Meyer T; Popp J; Heintzmann R
    J Microsc; 2015 Jun; 258(3):223-32. PubMed ID: 25787148
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of computerised correction method for optical distortion of two-dimensional facial image in superimposition between three-dimensional and two-dimensional facial images.
    Biwasaka H; Tokuta T; Sasaki Y; Sato K; Takagi T; Tanijiri T; Miyasaka S; Takamiya M; Aoki Y
    Forensic Sci Int; 2010 Apr; 197(1-3):97-104. PubMed ID: 20116945
    [TBL] [Abstract][Full Text] [Related]  

  • 20. FASTDEF: fast defocus and astigmatism estimation for high-throughput transmission electron microscopy.
    Vargas J; Otón J; Marabini R; Jonic S; de la Rosa-Trevín JM; Carazo JM; Sorzano CO
    J Struct Biol; 2013 Feb; 181(2):136-48. PubMed ID: 23261401
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.