These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
172 related articles for article (PubMed ID: 20452793)
1. Determination of optimal sampling times for a two blood sample clearance method using (51)Cr-EDTA in cats. Vandermeulen E; De Sadeleer C; Piepsz A; Ham HR; Dobbeleir AA; Vermeire ST; Van Hoek IM; Daminet S; Slegers G; Peremans KY J Feline Med Surg; 2010 Aug; 12(8):577-83. PubMed ID: 20452793 [TBL] [Abstract][Full Text] [Related]
2. Conventional measurements of GFR using 51Cr-EDTA overestimate true renal clearance by 10 percent. Moore AE; Park-Holohan SJ; Blake GM; Fogelman I Eur J Nucl Med Mol Imaging; 2003 Jan; 30(1):4-8. PubMed ID: 12483403 [TBL] [Abstract][Full Text] [Related]
3. Mannitol clearance for the determination of glomerular filtration rate-a validation against clearance of Kiss K; Molnár M; Söndergaard S; Molnár G; Ricksten SE Clin Physiol Funct Imaging; 2018 Jan; 38(1):10-16. PubMed ID: 27256921 [TBL] [Abstract][Full Text] [Related]
4. Clearance of iohexol, chromium-51-ethylenediaminetetraacetic acid, and creatinine for determining the glomerular filtration rate in pigs with normal renal function: comparison of different clearance techniques. Frennby B; Sterner G; Almén T; Chai CM; Jönsson BA; Månsson S Acad Radiol; 1996 Aug; 3(8):651-9. PubMed ID: 8796729 [TBL] [Abstract][Full Text] [Related]
5. A single sample method for evaluating 51chromium-ethylene diaminic tetraacetic acid clearance in normal and hyperthyroid cats. Vandermeulen E; van Hoek I; De Sadeleer C; Piepsz A; Ham HR; Bosmans T; Dobbeleir A; Daminet S; Peremans K J Vet Intern Med; 2008; 22(2):266-72. PubMed ID: 18312282 [TBL] [Abstract][Full Text] [Related]
6. Chromium-51-EDTA clearance in adults with a single-plasma sample. Mårtensson J; Groth S; Rehling M; Gref M J Nucl Med; 1998 Dec; 39(12):2131-7. PubMed ID: 9867156 [TBL] [Abstract][Full Text] [Related]
7. Simplified methods for estimating glomerular filtration rate in cats and for detection of cats with low or borderline glomerular filtration rate. Paepe D; Lefebvre HP; Concordet D; van Hoek I; Croubels S; Daminet S J Feline Med Surg; 2015 Oct; 17(10):889-900. PubMed ID: 25518848 [TBL] [Abstract][Full Text] [Related]
8. Reliability of ⁵¹Cr-EDTA plasma and urinary clearance as a measure of residual renal function in dialysis patients. Kjaergaard KD; Jensen JD; Jespersen B; Rehling M Scand J Clin Lab Invest; 2011 Dec; 71(8):663-9. PubMed ID: 21992070 [TBL] [Abstract][Full Text] [Related]
12. Measurement of the kidney function in patients with rheumatoid arthritis: plasma cystatin C versus 51Cr-EDTA clearance. Karstila K; Harmoinen AP; Lehtimäki TJ; Korpela MM; Mustonen JT; Saha HH Nephron Clin Pract; 2008; 108(4):c284-90. PubMed ID: 18434750 [TBL] [Abstract][Full Text] [Related]
13. Plasma clearance rate of 51Cr-EDTA provides a precise and convenient technique for measurement of glomerular filtration rate in diabetic humans. Sambataro M; Thomaseth K; Pacini G; Robaudo C; Carraro A; Bruseghin M; Brocco E; Abaterusso C; DeFerrari G; Fioretto P; Maioli M; Tonolo GC; Crepaldi G; Nosadini R J Am Soc Nephrol; 1996 Jan; 7(1):118-27. PubMed ID: 8808118 [TBL] [Abstract][Full Text] [Related]
14. Overestimation of true renal clearance by conventional measurements of GFR using 51Cr-EDTA. Hilson AJ Eur J Nucl Med Mol Imaging; 2003 Jun; 30(6):934; author reply 935. PubMed ID: 12709833 [No Abstract] [Full Text] [Related]
15. 68Ga-EDTA PET/CT imaging and plasma clearance for glomerular filtration rate quantification: comparison to conventional 51Cr-EDTA. Hofman M; Binns D; Johnston V; Siva S; Thompson M; Eu P; Collins M; Hicks RJ J Nucl Med; 2015 Mar; 56(3):405-9. PubMed ID: 25678493 [TBL] [Abstract][Full Text] [Related]
16. Measurement of glomerular filtration rate in cats: methods and advantages over routine markers of renal function. Finch N J Feline Med Surg; 2014 Sep; 16(9):736-48. PubMed ID: 25146661 [TBL] [Abstract][Full Text] [Related]
17. 51Cr-EDTA plasma clearance in children: One, two, or multiple samples? Pottel H; Goffin K; De Waele L; Levtchenko E; Delanaye P Medicine (Baltimore); 2022 Jan; 101(3):e28608. PubMed ID: 35060531 [TBL] [Abstract][Full Text] [Related]
18. Estimating GFR in children with 99mTc-DTPA renography: a comparison with single-sample 51Cr-EDTA clearance. Gutte H; Møller ML; Pfeifer AK; Thorup J; Borgwardt L; Borgwardt L; Kristoffersen US; Kjaer A Clin Physiol Funct Imaging; 2010 May; 30(3):169-74. PubMed ID: 20214666 [TBL] [Abstract][Full Text] [Related]
19. Estimation of glomerular filtration rate via 2- and 4-sample plasma clearance of iohexol and creatinine in clinically normal cats. Heiene R; Reynolds BS; Bexfield NH; Larsen S; Gerritsen RJ Am J Vet Res; 2009 Feb; 70(2):176-85. PubMed ID: 19231948 [TBL] [Abstract][Full Text] [Related]
20. A Population Pharmacokinetic Model for Kuan IHS; Duffull SB; Putt TL; Schollum JBW; Walker RJ; Wright DFB Clin Pharmacokinet; 2017 Jun; 56(6):671-678. PubMed ID: 27943221 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]