BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 20456650)

  • 21. Impact of upgrade to cardiac resynchronization therapy on ventricular arrhythmia frequency in patients with implantable cardioverter-defibrillators.
    Ermis C; Seutter R; Zhu AX; Benditt LC; VanHeel L; Sakaguchi S; Lurie KG; Lu F; Benditt DG
    J Am Coll Cardiol; 2005 Dec; 46(12):2258-63. PubMed ID: 16360055
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Radiation exposure to anaesthetists during interventional radiology.
    Ismail S; Khan F; Sultan N; Naqvi M
    Anaesthesia; 2010 Jan; 65(1):54-60. PubMed ID: 19922509
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Radiation dose to the radiologist's hand during continuous CT fluoroscopy-guided interventions.
    Stoeckelhuber BM; Leibecke T; Schulz E; Melchert UH; Bergmann-Koester CU; Helmberger T; Gellissen J
    Cardiovasc Intervent Radiol; 2005; 28(5):589-94. PubMed ID: 16132384
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radiation dose and risk from fluoroscopically guided percutaneous transhepatic biliary procedures.
    Stratakis J; Damilakis J; Hatzidakis A; Perisinakis K; Gourtsoyiannis N
    J Vasc Interv Radiol; 2006 Jan; 17(1):77-84. PubMed ID: 16415136
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Radiation exposure of the operator during cardiac catheter ablation procedures.
    Pantos I; Koukorava C; Nirgianaki E; Carinou E; Tzanalaridou E; Efstathopoulos EP; Katritsis DG
    Radiat Prot Dosimetry; 2012 Jul; 150(3):306-11. PubMed ID: 22234422
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Radiation exposure during catheter ablation of atrial fibrillation.
    Lickfett L; Mahesh M; Vasamreddy C; Bradley D; Jayam V; Eldadah Z; Dickfeld T; Kearney D; Dalal D; Lüderitz B; Berger R; Calkins H
    Circulation; 2004 Nov; 110(19):3003-10. PubMed ID: 15505084
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Left ventricular mechanical assist devices and cardiac device interactions: an observational case series.
    Foo D; Walker BD; Kuchar DL; Thorburn CW; Tay A; Hayward CS; Macdonald P; Keogh A; Kotlyar E; Spratt P; Jansz P
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):879-87. PubMed ID: 19572863
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fluoroscopy reduction during device implantation by using three-dimensional navigation. A single-center experience.
    Larsen TR; Saini A; Moore J; Huizar JF; Tan AY; Ellenbogen KA; Kaszala K
    J Cardiovasc Electrophysiol; 2019 Oct; 30(10):2027-2033. PubMed ID: 31392815
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Utilization of defibrillators and resynchronization therapy at the time of evaluation at a heart failure and cardiac transplantation center.
    Sims DB; Garcia LI; Mignatti A; Colombo PC; Jones M; Uriel N; Mancini DM; Jorde UP
    Pacing Clin Electrophysiol; 2010 Aug; 33(8):988-93. PubMed ID: 20353413
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Reduction of radiation exposure for patient and investigator in interventional radiography].
    Pecher G; Koenig H; Pecher S; Gosch D; Voigt P; Schulz HG
    Rofo; 1998 Nov; 169(5):505-9. PubMed ID: 9849601
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Radiation dosage from use of the image intensifier in orthopaedic surgery.
    Lo NN; Goh PS; Khong KS
    Singapore Med J; 1996 Feb; 37(1):69-71. PubMed ID: 8783918
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Patient skin dose in cardiac interventional procedures: conventional fluoroscopy versus pulsed fluoroscopy.
    Chida K; Fuda K; Saito H; Takai Y; Takahashi S; Yamada S; Kohzuki M; Zuguchi M
    Catheter Cardiovasc Interv; 2007 Jan; 69(1):115-21; discussion 122. PubMed ID: 17139653
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Implantable defibrillators and cardiac resynchronization therapy in heart transplant recipients: results of a national survey.
    McDowell DL; Hauptman PJ
    J Heart Lung Transplant; 2009 Aug; 28(8):847-50. PubMed ID: 19632584
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
    Francisco GM; Sharma S; Dougherty AH; Kantharia BK
    Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Radiation protection in interventional radiology.
    Johnson DR; Kyriou J; Morton EJ; Clifton A; Fitzgerald M; Macsweeney E
    Clin Radiol; 2001 Feb; 56(2):99-106. PubMed ID: 11222065
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Impact of cardiac resynchronisation therapy on cardiologists' exposure to radiation during implantation of pacemakers and implantable cardioverter-defibrillators.
    Daval C; Faroux L; Lesaffre F; Blanpain T; Chabert JP; Martin A; Guinot M; Luconi N; Espinosa M; Nazeyrollas P; Tourneux C; Metz D
    J Radiol Prot; 2019 Apr; 39(2):489-497. PubMed ID: 30913548
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Radiation exposure to patients' skin during cardiac resynchronization therapy.
    Suzuki S; Furui S; Yamakawa T; Isshiki T; Watanabe A; Iino R; Kidouchi T; Nakano Y
    Europace; 2009 Dec; 11(12):1683-8. PubMed ID: 19846432
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Mid-term outcomes of triple-site vs. conventional cardiac resynchronization therapy: a preliminary study.
    Lenarczyk R; Kowalski O; Kukulski T; Pruszkowska-Skrzep P; Sokal A; Szulik M; Zielińska T; Kowalczyk J; Pluta S; Sredniawa B; Musialik-Łydka A; Kalarus Z
    Int J Cardiol; 2009 Mar; 133(1):87-94. PubMed ID: 18242737
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Long-term retention of cardiac resynchronization therapy.
    Knight BP; Desai A; Coman J; Faddis M; Yong P
    J Am Coll Cardiol; 2004 Jul; 44(1):72-7. PubMed ID: 15234410
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Variations of patient doses in interventional examinations at different angiographic units.
    Bor D; Toklu T; Olğar T; Sancak T; Cekirge S; Onal B; Bilgiç S
    Cardiovasc Intervent Radiol; 2006; 29(5):797-806. PubMed ID: 16718424
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.