These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 20457784)

  • 1. Field performance of the CATHIA-T sampler and two cyclones against the standard Cowled sampler for thoracic fiber concentrations.
    Lee EG; Nelson J; Hintz PJ; Joy G; Andrew ME; Harper M
    Ann Occup Hyg; 2010 Jul; 54(5):545-56. PubMed ID: 20457784
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of the CATHIA-T sampler, the GK2.69 cyclone and the standard cowled sampler for thoracic fiber concentrations at a Taconite (iron ore)-processing mill.
    Lee EG; Harper M; Nelson J; Hintz PJ; Andrew ME
    Ann Occup Hyg; 2008 Jan; 52(1):55-62. PubMed ID: 18195326
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thoracic size-selective sampling of fibres: performance of four types of thoracic sampler in laboratory tests.
    Jones AD; Aitken RJ; Fabriès JF; Kauffer E; Liden G; Maynard A; Riediger G; Sahle W
    Ann Occup Hyg; 2005 Aug; 49(6):481-92. PubMed ID: 15790615
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of mounting methods for the evaluation of fibers by phase contrast microscopy.
    Lee EG; Pang TW; Nelson J; Andrew M; Harper M
    Ann Occup Hyg; 2011 Jul; 55(6):644-57. PubMed ID: 21642614
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Air sampling methodology for asphalt fume in asphalt production and asphalt roofing manufacturing facilities: total particulate sampler versus inhalable particulate sampler.
    Calzavara TS; Carter CM; Axten C
    Appl Occup Environ Hyg; 2003 May; 18(5):358-67. PubMed ID: 12746079
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of the thoracic sampling definition to fiber measurement.
    Baron PA
    Am Ind Hyg Assoc J; 1996 Sep; 57(9):820-4. PubMed ID: 8865590
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Calibration of high flow rate thoracic-size selective samplers.
    Lee T; Thorpe A; Cauda E; Harper M
    J Occup Environ Hyg; 2016; 13(6):D93-8. PubMed ID: 26891196
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of portable XRF and ICP-OES analysis for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler.
    Harper M; Pacolay B; Hintz P; Andrew ME
    J Environ Monit; 2006 Mar; 8(3):384-92. PubMed ID: 16528423
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of PUF foam inserts for respirable dust measurements in the brick-manufacturing industry.
    De Vocht F; Hirst A; Gardner A
    Ann Occup Hyg; 2009 Jan; 53(1):19-25. PubMed ID: 18977848
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Presence of airborne fibers in tungsten refining and manufacturing processes: preliminary characterization.
    McKernan JL; Toraason MA; Fernback JE
    J Occup Environ Hyg; 2008 Jul; 5(7):463-74. PubMed ID: 18569509
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of portable, real-time dust monitors sampling actively, with size-selective adaptors, and passively.
    Thorpe A; Walsh PT
    Ann Occup Hyg; 2007 Nov; 51(8):679-91. PubMed ID: 18024485
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of X-ray fluorescence and wet chemical analysis of air filter samples from a scrap lead smelting operation.
    Harper M; Hallmark TS; Andrew ME; Bird AJ
    J Environ Monit; 2004 Oct; 6(10):819-26. PubMed ID: 15480496
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thoracic size-selection of fibres: dependence of penetration on fibre length for five thoracic sampler types.
    Maynard AD
    Ann Occup Hyg; 2002 Aug; 46(6):511-22. PubMed ID: 12176765
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance of high flow rate samplers for respirable particle collection.
    Lee T; Kim SW; Chisholm WP; Slaven J; Harper M
    Ann Occup Hyg; 2010 Aug; 54(6):697-709. PubMed ID: 20660144
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Field evaluation of nanofilm detectors for measuring acidic particles in indoor and outdoor air.
    Cohen BS; Heikkinen MS; Hazi Y; Gao H; Peters P; Lippmann M
    Res Rep Health Eff Inst; 2004 Sep; (121):1-35; discussion 37-46. PubMed ID: 15553489
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A field comparison of inhalable and thoracic size selective sampling techniques.
    Davies HW; Teschke K; Demers PA
    Ann Occup Hyg; 1999 Aug; 43(6):381-92. PubMed ID: 10518464
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a personal and microenvironmental aerosol speciation sampler (PMASS).
    Geyh AS; Hering S; Kreisberg N; John W
    Res Rep Health Eff Inst; 2004 Nov; (122):1-22; discussion 23-9. PubMed ID: 15675716
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of pump pulsation in respirable size-selective sampling: part II. Changes in sampling efficiency.
    Lee EG; Lee T; Kim SW; Lee L; Flemmer MM; Harper M
    Ann Occup Hyg; 2014 Jan; 58(1):74-84. PubMed ID: 24064963
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr-Oliver nylon cyclones operated at 1.7 and 2.0 L min(-1).
    Page SJ; Volkwein JC
    J Environ Monit; 2009 Mar; 11(3):684-9. PubMed ID: 19280048
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chamber evaluation of a personal, bioaerosol cyclone sampler.
    Macher J; Chen B; Rao C
    J Occup Environ Hyg; 2008 Nov; 5(11):702-12. PubMed ID: 18720289
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.