BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 20459354)

  • 1. Evaluation of the TEST 1 erythrocyte sedimentation rate system and intra- and inter-laboratory quality control using new latex control materials.
    Cha CH; Cha YJ; Park CJ; Kim HK; Cha EJ; Kim DH; Honghoon ; Jung JS; Kim MJ; Jang S; Chi HS; Lee DS
    Clin Chem Lab Med; 2010 Jul; 48(7):1043-8. PubMed ID: 20459354
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new turbidimetric standard to improve the quality assurance of the erythrocyte sedimentation rate measurement.
    Piva E; Pajola R; Temporin V; Plebani M
    Clin Biochem; 2007 Apr; 40(7):491-5. PubMed ID: 17306243
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Erythrocyte sedimentation rate: use of fresh blood for quality control.
    Plebani M; Piva E
    Am J Clin Pathol; 2002 Apr; 117(4):621-6. PubMed ID: 11939738
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyzer using the Westergren ESR method in patients with systemic inflammatory conditions.
    Happe MR; Battafarano DF; Dooley DP; Rennie TA; Murphy FT; Casey TJ; Ward JA
    Am J Clin Pathol; 2002 Jul; 118(1):14-7. PubMed ID: 12109848
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Length of erythrocyte sedimentation rate (ESR) adjusted for the hematocrit: reference values for the TEST 1 method.
    Giavarina D; Capuzzo S; Pizzolato U; Soffiati G
    Clin Lab; 2006; 52(5-6):241-5. PubMed ID: 16812950
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interinstitutional comparison of bedside blood glucose monitoring program characteristics, accuracy performance, and quality control documentation: a College of American Pathologists Q-Probes study of bedside blood glucose monitoring performed in 226 small hospitals.
    Novis DA; Jones BA
    Arch Pathol Lab Med; 1998 Jun; 122(6):495-502. PubMed ID: 9625416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Erythrocyte sedimentation rate (ESR) measured by the Streck ESR-Auto Plus is higher than with the Sediplast Westergren method: a validation study.
    Vennapusa B; De La Cruz L; Shah H; Michalski V; Zhang QY
    Am J Clin Pathol; 2011 Mar; 135(3):386-90. PubMed ID: 21350092
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Test-1 analyzer and conventional Westergren method for erythrocyte sedimentation rate: A comparative study between two laboratories.
    Sonmez C; Dogan OC; Kaymak AO; Akkaya N; Akin KO; Guntas G
    J Clin Lab Anal; 2018 Jun; 32(5):e22384. PubMed ID: 29341286
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calibration and validation for erythrocyte sedimentation tests. Role of the International Committee on Standardization in Hematology reference procedure.
    Thomas RD; Westengard JC; Hay KL; Bull BS
    Arch Pathol Lab Med; 1993 Jul; 117(7):719-23. PubMed ID: 8323437
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-way comparison of methods for the measurement of the erythrocyte sedimentation rate.
    Mahlangu JN; Davids M
    J Clin Lab Anal; 2008; 22(5):346-52. PubMed ID: 18803269
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The TEST 1 automated system: a new method for measuring the erythrocyte sedimentation rate.
    Plebani M; De Toni S; Sanzari MC; Bernardi D; Stockreiter E
    Am J Clin Pathol; 1998 Sep; 110(3):334-40. PubMed ID: 9728608
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The VES-Matic 5 system: performance of a novel instrument for measuring erythrocyte sedimentation rate.
    Piva E; Stoppa A; Pelloso M; Plebani M
    Clin Chem Lab Med; 2022 Jun; 60(7):1081-1090. PubMed ID: 35535422
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Ves-Matic Cube 200--an automated system for the measurement of the erythrocyte sedimentation rate.
    Perovic E; Bakovic L; Valcic A
    Int J Lab Hematol; 2010 Feb; 32(1 Pt 2):88-94. PubMed ID: 19170776
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of ESR analyzer using Westergren ESR method.
    Sikka M; Tandon R; Rusia U; Madan N
    Indian J Pathol Microbiol; 2007 Jul; 50(3):634-5. PubMed ID: 17883168
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Differences in erythrocyte sedimentation rates using the Westergren method and a centrifugation method.
    Shelat SG; Chacosky D; Shibutani S
    Am J Clin Pathol; 2008 Jul; 130(1):127-30. PubMed ID: 18550481
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Turning point in quality control: problems at present and themes in future].
    Naka H
    Rinsho Byori; 1993 May; 41(5):573-7. PubMed ID: 8350526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ves-Matic CUBE 200: is modified Westergren method for erythrocyte sedimentation rate a valid alternative to the gold standard?
    Lapić I; Piva E; Spolaore F; Musso G; Tosato F; Pelloso M; Plebani M
    J Clin Pathol; 2019 Oct; 72(10):716-719. PubMed ID: 31154424
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy study of a novel alternate method measuring erythrocyte sedimentation rate for prototype hematology analyzer Celltac α.
    Maki R; Tabe Y; Yamamoto T; Takemura H; Sawada T; Esaki T; Higuchi M; Misawa S; Miyake K; Miida T; Nagai Y; Ohsaka A
    Int J Lab Hematol; 2021 Aug; 43(4):588-596. PubMed ID: 33929779
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Length of sedimentation reaction in blood: a comparison of the test 1 ESR system with the ICSH reference method and the sedisystem 15.
    Romero A; Muñoz M; Ramírez G
    Clin Chem Lab Med; 2003 Feb; 41(2):232-7. PubMed ID: 12667012
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Length of sedimentation reaction in undiluted blood (erythrocyte sedimentation rate): variations with sex and age and reference limits.
    Piva E; Sanzari MC; Servidio G; Plebani M
    Clin Chem Lab Med; 2001 May; 39(5):451-4. PubMed ID: 11434396
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.