  • 1. Editorial: late-term displacement of Amplatzer Duct Occluder II device following percutaneous closure of patent ductus arteriosus in an adult.
    Barcin C; Kursaklioglu H
    J Interv Cardiol; 2010 Aug; 23(4):368-9. PubMed ID: 20459457
    [No Abstract]   [Full Text] [Related]  

  • 2. The Amplatzer Duct Occluder II: a new device for percutaneous ductus arteriosus closure.
    Saliba Z; El-Rassi I; Abi-Warde MT; Chehab G; Daou L; Khater D; Gerbaka B; Jebara V
    J Interv Cardiol; 2009 Dec; 22(6):496-502. PubMed ID: 19780890
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transradial approach for percutaneous closure of patent ductus arteriosus with the Amplatzer duct occluder II: a case report.
    Cassese S; Losi MA; Rapacciuolo A
    Catheter Cardiovasc Interv; 2011 Jan; 77(1):103-7. PubMed ID: 20925092
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Percutaneous closure of the patent ductus arteriosus in children with the Amplatzer Duct Occluder II].
    Parra-Bravo JR; Osuna-Izaguirre MA; Beirana-Palencia L; Gálvez-Cancino F; Martínez-Monterrosas C; Lazo-Cárdenas C; Reyes-Vargas C
    Arch Cardiol Mex; 2014; 84(3):171-6. PubMed ID: 24998666
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].
    Parra-Bravo JR; Apolonio-Martínez A; Estrada-Loza Mde J; Beirana-Palencia LG; Ramírez-Portillo CI
    Arch Cardiol Mex; 2015; 85(3):188-94. PubMed ID: 25700578
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The new Amplatzer duct occluder II: when is its use advantageous?
    Venczelova Z; Tittel P; Masura J
    Cardiol Young; 2011 Oct; 21(5):495-504. PubMed ID: 21426608
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter closure of patent ductus arteriosus using the amplatzer duct occluder in infants under 1 year of age.
    Parra-Bravo R; Cruz-Ramírez A; Rebolledo-Pineda V; Robles-Cervantes J; Chávez-Fernández A; Beirana-Palencia L; Jiménez-Montufar L; Estrada-Loza Mde J; Estrada-Flores J; Báez-Zamudio N; Escobar-Ponce M
    Rev Esp Cardiol; 2009 Aug; 62(8):867-74. PubMed ID: 19706242
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Percutaneous closure of patent ductus arteriosus using the Amplatzer vascular Plug II].
    Parra-Bravo R; Beirana-Palencia L; Corona-Rodríguez A; Alarcón-Elguera L; Tejeda-Hernández N; Aguilar-Segura P; Lazo-Cárdenas C; Arellano-Llamas A
    Arch Cardiol Mex; 2011; 81(2):108-13. PubMed ID: 21775244
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder in children: initial and one-year results].
    Parra-Bravo JR; Cruz-Ramírez A; Toxqui-Terán A; Juan-Martínez E; Chávez-Fernández AA; Lazo-Cárdenas C; Beirana-Palencia L; Estrada-Flores J
    Arch Cardiol Mex; 2009; 79(2):114-20. PubMed ID: 19722381
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Percutaneous closure of patent ductus arteriosus with the Amplatzer duct occluder. Results of 29 patients].
    Godart F; Rey C; Francart C; Vaksmann G; Brevière GM
    Arch Mal Coeur Vaiss; 2001 May; 94(5):439-43. PubMed ID: 11434010
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].
    Santiago J; Acuña M; Arispe E; Camargo R; Neves J; Arnoni D; Fontes VF; Pedra CA
    Rev Esp Cardiol; 2007 Mar; 60(3):319-22. PubMed ID: 17394880
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Closure of a large ductus arteriosus in a preterm infant using the ADO II AS device.
    Agnoletti G; Bordese R; Gabbarini F
    Heart; 2012 Sep; 98(18):1394. PubMed ID: 22689710
    [No Abstract]   [Full Text] [Related]  

  • 13. Analyzing the failures of percutaneous closure of the patent ductus arteriosus in patients over 5 kg.
    Saliba Z; El-Rassi I; Helou D; Chehab G; Abdel-Massih T; Daou L; Chalhoub V; Choueiry E; Gerbaka B
    J Invasive Cardiol; 2012 Sep; 24(9):434-8. PubMed ID: 22954562
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Closure of a short patent ductus arteriosus using an atrial septal occluder.
    Zanjani KS
    Chin Med J (Engl); 2010 May; 123(9):1220-1. PubMed ID: 20529567
    [No Abstract]   [Full Text] [Related]  

  • 15. Comparison of percutaneous closure of large patent ductus arteriosus by multiple coils versus the Amplatzer duct occluder device.
    Santoro G; Bigazzi MC; Palladino MT; Russo MG; Carrozza M; Calabrò R
    Am J Cardiol; 2004 Jul; 94(2):252-5. PubMed ID: 15246917
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The off-label use of the Amplatzer muscular VSD occluder for large patent ductus arteriosus: a case report and review.
    Cubeddu RJ; Babin I; Inglessis I
    Cardiovasc Interv Ther; 2014 Jul; 29(3):256-60. PubMed ID: 24203581
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Closure of a very large patent ductus arteriosus using the amplatzer duct occluder.
    Hoyer MH
    J Invasive Cardiol; 2002 Sep; 14(9):531-4. PubMed ID: 12205354
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evolution of strategies for management of the patent arterial duct.
    Giroud JM; Jacobs JP
    Cardiol Young; 2007 Sep; 17 Suppl 2():68-74. PubMed ID: 18039400
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous closure of a patent arterial duct in a newborn.
    Prada FH; Carretero JM; Jimenez L
    Cardiol Young; 2009 Aug; 19(4):400-2. PubMed ID: 19442317
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcatheter closure of moderate to large patent ductus arteriosus with the Amplatzer duct occluder.
    Wang JK; Wu MH; Hwang JJ; Chiang FT; Lin MT; Lue HC
    Catheter Cardiovasc Interv; 2007 Mar; 69(4):572-8. PubMed ID: 17323360
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]