21. Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock. Mozina H; Podbregar M Crit Care; 2010; 14(2):R42. PubMed ID: 20331856 [TBL] [Abstract][Full Text] [Related]
23. Near-infrared spectroscopy for assessing tissue oxygenation and microvascular reactivity in critically ill patients: a prospective observational study. Donati A; Damiani E; Domizi R; Scorcella C; Carsetti A; Tondi S; Monaldi V; Adrario E; Romano R; Pelaia P; Singer M Crit Care; 2016 Oct; 20(1):311. PubMed ID: 27716370 [TBL] [Abstract][Full Text] [Related]
24. Frequency domain analysis of cerebral near infrared spectroscopy signals during application of an impedance threshold device in spontaneously ventilating volunteers. Colquhoun DA; Naden K; Thiele RH J Clin Monit Comput; 2016 Aug; 30(4):389-98. PubMed ID: 26115773 [TBL] [Abstract][Full Text] [Related]
25. Tissue oxygen saturation assessment of microvascular perfusion in adults with Fontan palliation and comparator groups using vascular optical spectrophotometry: a pilot study. Agarwal R; Chaudhry B; Jansen K; O'Sullivan J; Hudson M; Allen J; Coats L Physiol Meas; 2019 Jul; 40(6):06NT01. PubMed ID: 31051474 [TBL] [Abstract][Full Text] [Related]
26. Near-infrared spectroscopy assessment of tissue saturation of oxygen in torsed and healthy testes. Schoenfeld EM; Capraro GA; Blank FS; Coute RA; Visintainer PF Acad Emerg Med; 2013 Oct; 20(10):1080-3. PubMed ID: 24127717 [TBL] [Abstract][Full Text] [Related]
27. Assessment of hand superficial oxygenation during ischemia/reperfusion in healthy subjects versus systemic sclerosis patients by 2D near infrared spectroscopic imaging. Jalil B; Hartwig V; Salvetti O; Potì L; Gargani L; Barskova T; Matucci Cerinic M; L'Abbate A Comput Methods Programs Biomed; 2018 Mar; 155():101-108. PubMed ID: 29512489 [TBL] [Abstract][Full Text] [Related]
28. A low-cost, wireless near-infrared spectroscopy device detects the presence of lower extremity atherosclerosis as measured by computed tomographic angiography and characterizes walking impairment in peripheral artery disease. Fuglestad MA; Hernandez H; Gao Y; Ybay H; Schieber MN; Brunette KE; Myers SA; Casale GP; Pipinos II J Vasc Surg; 2020 Mar; 71(3):946-957. PubMed ID: 31445826 [TBL] [Abstract][Full Text] [Related]
29. Microvascular Reactivity Measured by Dynamic Near-infrared Spectroscopy Following Induction of General Anesthesia in Healthy Patients: Observation of Age-related Change. Cho AR; Lee HJ; Kim HJ; Do W; Jeon S; Baek SH; Kim ES; Kwon JY; Kim HK Int J Med Sci; 2021; 18(5):1096-1103. PubMed ID: 33526968 [No Abstract] [Full Text] [Related]
30. Reference range for tissue oxygen saturation in pregnancy using near-infrared spectroscopy. Stager RD; Fakih MA; Churley-Strom R; Singal B; Purtill MA J Reprod Med; 2015; 60(3-4):149-54. PubMed ID: 25898478 [TBL] [Abstract][Full Text] [Related]
31. Comparison of four different vascular occlusion tests for assessing reactive hyperemia using near-infrared spectroscopy. Mayeur C; Campard S; Richard C; Teboul JL Crit Care Med; 2011 Apr; 39(4):695-701. PubMed ID: 21220999 [TBL] [Abstract][Full Text] [Related]
32. Monitoring of Foot Oxygenation with Near-infrared Spectroscopy in Patients with Critical Limb Ischemia Undergoing Percutaneous Transluminal Angioplasty: A Pilot Study. Boezeman RP; Becx BP; van den Heuvel DA; Ünlü Ç; Vos JA; de Vries JP Eur J Vasc Endovasc Surg; 2016 Nov; 52(5):650-656. PubMed ID: 27614555 [TBL] [Abstract][Full Text] [Related]
33. Detection of cutaneous oxygen saturation using a novel snapshot hyperspectral camera: a feasibility study. van Manen L; Birkhoff WAJ; Eggermont J; Hoveling RJM; Nicklin P; Burggraaf J; Wilson R; Mieog JSD; Robinson DJ; Vahrmeijer AL; Bradbury MS; Dijkstra J Quant Imaging Med Surg; 2021 Sep; 11(9):3966-3977. PubMed ID: 34476182 [TBL] [Abstract][Full Text] [Related]
36. Age-related microvascular dysfunction: novel insight from near-infrared spectroscopy. Rosenberry R; Munson M; Chung S; Samuel TJ; Patik J; Tucker WJ; Haykowsky MJ; Nelson MD Exp Physiol; 2018 Feb; 103(2):190-200. PubMed ID: 29114952 [TBL] [Abstract][Full Text] [Related]
37. Near-infrared spectroscopy-derived tissue oxygen saturation in battlefield injuries: a case series report. Beilman GJ; Blondet JJ World J Emerg Surg; 2009 Jun; 4():25. PubMed ID: 19545387 [TBL] [Abstract][Full Text] [Related]
38. Increasing mean arterial pressure in cardiogenic shock secondary to myocardial infarction: effects on hemodynamics and tissue oxygenation. Perez P; Kimmoun A; Blime V; Levy B Shock; 2014 Apr; 41(4):269-74. PubMed ID: 24509521 [TBL] [Abstract][Full Text] [Related]
39. Reliability of microvascular responsiveness measures derived from near-infrared spectroscopy across a variety of ischemic periods in young and older individuals. Iannetta D; Inglis EC; Soares RN; McLay KM; Pogliaghi S; Murias JM; Microvasc Res; 2019 Mar; 122():117-124. PubMed ID: 30292692 [TBL] [Abstract][Full Text] [Related]
40. 'Real angiosome' assessment from peripheral tissue perfusion using tissue oxygen saturation foot-mapping in patients with critical limb ischemia. Kagaya Y; Ohura N; Suga H; Eto H; Takushima A; Harii K Eur J Vasc Endovasc Surg; 2014 Apr; 47(4):433-41. PubMed ID: 24412085 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]