These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 2046615)

  • 1. Evaluation of neutron dose equivalent levels at the maze entrance of medical accelerator treatment rooms.
    McGinley PH; Butker EK
    Med Phys; 1991; 18(2):279-81. PubMed ID: 2046615
    [TBL] [Abstract][Full Text] [Related]  

  • 2. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities.
    Kim HS; Jang KW; Park YH; Kwon JW; Choi HS; Lee JK; Kim JK
    Med Phys; 2009 May; 36(5):1512-20. PubMed ID: 19544767
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
    Wang X; Esquivel C; Nes E; Shi C; Papanikolaou N; Charlton M
    Med Phys; 2011 Mar; 38(3):1141-9. PubMed ID: 21520826
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of neutron dose in the maze of medical electron accelerators.
    Carinou E; Kamenopoulou V; Stamatelatos IE
    Med Phys; 1999 Dec; 26(12):2520-5. PubMed ID: 10619233
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
    Falcão RC; Facure A; Silva AX
    Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the photoneutron field produced in a medical linear accelerator.
    Kim HS; Park YH; Koo BC; Kwon JW; Lee JS; Choi HS
    Radiat Prot Dosimetry; 2007; 123(3):323-8. PubMed ID: 17077093
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of a BF3 remmeter to calibrate neutron activation foils in the medical linear accelerator environment.
    Borchardt IM; Beckham WA; Sorell GC; Beddoe AH
    Australas Phys Eng Sci Med; 1992 Jun; 15(2):101-4. PubMed ID: 1642569
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The evaluation of the neutron dose equivalent in the two-bend maze.
    Tóth ÁÁ; Petrović B; Jovančević N; Krmar M; Rutonjski L; Čudić O
    Phys Med; 2017 Apr; 36():119-125. PubMed ID: 28410680
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator.
    Krmar M; Nikolić D; Kuzmanović A; Kuzmanović Z; Ganezer K
    Med Phys; 2013 Aug; 40(8):083902. PubMed ID: 23927362
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Neutron and capture gamma along the mazes of linear accelerator vaults.
    Wu RK; McGinley PH
    J Appl Clin Med Phys; 2003; 4(2):162-71. PubMed ID: 12777152
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neutron energies in medical electron accelerator rooms.
    LaRiviere PD
    Med Phys; 1985; 12(6):769-75. PubMed ID: 4079870
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Leakage radiations in a medical electron accelerator facility--calculation of neutron doses in the facility].
    Ishimatsu K; Morikawa K
    Radioisotopes; 1990 Feb; 39(2):29-36. PubMed ID: 2326507
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
    Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
    Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Neutron dose equivalent measured at the maze door with various openings for the jaws and MLC.
    Krmar M; Baucal M; Bozic N; Jovancevic N; Ciraj-Bjelac O
    Med Phys; 2012 Mar; 39(3):1278-81. PubMed ID: 22380359
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The measurement of photoneutron dose in the vicinity of clinical linear accelerators.
    Rivera JC; Falcão RC; Dealmeida CE
    Radiat Prot Dosimetry; 2008; 130(4):403-9. PubMed ID: 18375468
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The neutron dose and energy spectrum outside a 20-MV accelerator treatment room.
    Muller-Runkel R; Ovadia J; Culbert H; Cooke RH; Dolecek EH
    Med Phys; 1986; 13(5):742-7. PubMed ID: 3097465
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Leakage radiations in a medical electron accelerator facility--measurement of neutrons and comparison with calculation].
    Morikawa K; Ishimatsu K
    Radioisotopes; 1990 Feb; 39(2):37-44. PubMed ID: 2326508
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Shielding design and detection of neutrons from medical and industrial electron accelerators--simple method of design calculation for neutron shielding].
    Nakamura T; Uwamino Y
    Radioisotopes; 1986 Feb; 35(2):51-6. PubMed ID: 3704202
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiation protection aspects of a new high-energy linear accelerator.
    O'Brien P; Michaels HB; Gillies B; Aldrich JE; Andrew JW
    Med Phys; 1985; 12(1):101-7. PubMed ID: 3919249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Be aware of neutrons outside short mazes from 10-MV linear accelerators X-rays in radiotherapy facilities.
    Brockstedt S; Holstein H; Jakobsson L; Tomaszewicz A; Knöös T
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):464-7. PubMed ID: 25802465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.