These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 20469547)

  • 1. Distal interphalangeal articular cartilage assessment using low-field magnetic resonance imaging.
    Olive J
    Vet Radiol Ultrasound; 2010; 51(3):259-66. PubMed ID: 20469547
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients.
    Bredella MA; Tirman PF; Peterfy CG; Zarlingo M; Feller JF; Bost FW; Belzer JP; Wischer TK; Genant HK
    AJR Am J Roentgenol; 1999 Apr; 172(4):1073-80. PubMed ID: 10587150
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of sequence selection and field strength on detection of osteochondral defects in the metacarpophalangeal joint.
    Werpy NM; Ho CP; Pease AP; Kawcak CE
    Vet Radiol Ultrasound; 2011; 52(2):154-60. PubMed ID: 21388466
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magic angle effect in normal collateral ligaments of the distal interphalangeal joint in horses imaged with a high-field magnetic resonance imaging system.
    Werpy NM; Ho CP; Kawcak CE
    Vet Radiol Ultrasound; 2010; 51(1):2-10. PubMed ID: 20166386
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparison between pig lumbar zypapophyseal joint cartilage acquired from multiple magnetic resonance image sequences and gross specimens].
    Liao H; Yu W; Wang W; Liao Y
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2010 Oct; 35(10):1064-72. PubMed ID: 21051831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of magnetic resonance imaging for measurement of equine articular cartilage and subchondral bone thickness.
    Murray RC; Branch MV; Tranquille C; Woods S
    Am J Vet Res; 2005 Nov; 66(11):1999-2005. PubMed ID: 16334962
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fat-suppressed 3D-T1-weighted-echo planar imaging: comparison with fat-suppressed 3D-T1-weighted-gradient echo in imaging the cartilage of the knee.
    Karantanas AH; Zibis AH; Kitsoulis P
    Comput Med Imaging Graph; 2002; 26(3):159-65. PubMed ID: 11918977
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Magnetic resonance study of patellofemoral cartilage with a fat-suppressed T1-3D gradient-echo sequence: a comparison with other acquisition technics at medium field strength].
    Cardone G; Minio Paluello GB; Lo Presti G; Gagliardo O; Gallucci M; Castrucci M
    Radiol Med; 1997 Sep; 94(3):150-6. PubMed ID: 9446117
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Identification of Naturally Occurring Cartilage Damage in the Equine Distal Interphalangeal Joint Using Low-Field Magnetic Resonance Imaging and Magnetic Resonance Arthrography.
    van Zadelhoff C; Schwarz T; Smith S; Engerand A; Taylor S
    Front Vet Sci; 2019; 6():508. PubMed ID: 32064268
    [No Abstract]   [Full Text] [Related]  

  • 10. Detection of articular cartilage lesions: experimental evaluation of low- and high-field-strength MR imaging at 0.18 and 1.0 T.
    Woertler K; Strothmann M; Tombach B; Reimer P
    J Magn Reson Imaging; 2000 Jun; 11(6):678-85. PubMed ID: 10862068
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging: comparison with standard MR imaging and correlation with arthroscopy.
    Disler DG; McCauley TR; Wirth CR; Fuchs MD
    AJR Am J Roentgenol; 1995 Aug; 165(2):377-82. PubMed ID: 7618561
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical magnetic resonance imaging of articular cartilage.
    Disler DG; McCauley TR
    Top Magn Reson Imaging; 1998 Dec; 9(6):360-76. PubMed ID: 9894739
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Synthetic-echo time postprocessing technique for generating images with variable T2-weighted contrast: diagnosis of meniscal and cartilage abnormalities of the knee.
    Andreisek G; White LM; Theodoropoulos JS; Naraghi A; Young N; Zhao CY; Mamisch TC; Sussman MS
    Radiology; 2010 Jan; 254(1):188-99. PubMed ID: 20032152
    [TBL] [Abstract][Full Text] [Related]  

  • 14. MR arthrography of the hip: diagnostic performance of a dedicated water-excitation 3D double-echo steady-state sequence to detect cartilage lesions.
    Knuesel PR; Pfirrmann CW; Noetzli HP; Dora C; Zanetti M; Hodler J; Kuehn B; Schmid MR
    AJR Am J Roentgenol; 2004 Dec; 183(6):1729-35. PubMed ID: 15547220
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of patellar chondromalacia with MR: comparison between T2-weighted FSE SPIR and GE MTC.
    Macarini L; Perrone A; Murrone M; Marini S; Stefanelli M
    Radiol Med; 2004 Sep; 108(3):159-71. PubMed ID: 15343130
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fat suppression gradient-echo magnetic resonance imaging of experimental articular cartilage lesions: comparison between phase-contrast method at 0.23T and chemical shift selective method at 1.5T.
    Palosaari K; Ojala R; Blanco-Sequeiros R; Tervonen O
    J Magn Reson Imaging; 2003 Aug; 18(2):225-31. PubMed ID: 12884336
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3T system scientific research.
    Milewski MD; Smitaman E; Moukaddam H; Katz LD; Essig DA; Medvecky MJ; Haims AH
    Eur J Radiol; 2012 Jul; 81(7):1637-43. PubMed ID: 21683539
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Magnetic resonance of the cartilages of the large joints].
    Chalkias S; Frezza F; Cova M; Pozzi Mucelli R; Pozzi Mucelli M; Dalla Palma L
    Radiol Med; 1994 May; 87(5):555-73. PubMed ID: 8008884
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Low field magnetic resonance imaging of the equine distal interphalangeal joint: Comparison between weight-bearing and non-weight-bearing conditions.
    Evrard L; Audigié F; Bertoni L; Jacquet S; Denoix JM; Busoni V
    PLoS One; 2019; 14(1):e0211101. PubMed ID: 30689659
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of standard hip MR arthrographic imaging planes and sequences for detection of arthroscopically proven labral tear.
    Ziegert AJ; Blankenbaker DG; De Smet AA; Keene JS; Shinki K; Fine JP
    AJR Am J Roentgenol; 2009 May; 192(5):1397-400. PubMed ID: 19380568
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.