These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 20478771)

  • 21. An evaluation of blood creatinine measurement by creatinase on the NOVA M7 blood gas analyzer.
    Rowe DJ; Omar H; Barratt SL; Biggs P
    Clin Chim Acta; 2001 May; 307(1-2):23-5. PubMed ID: 11369332
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison between the enzymatic vitros assay for creatinine determination and three other methods adapted on the Olympus analyzer.
    Badiou S; Dupuy AM; Descomps B; Cristolead JP
    J Clin Lab Anal; 2003; 17(6):235-40. PubMed ID: 14614747
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Laboratory evaluation of the UniCel DxI 800 analyser (Beckman Coulter) for detecting HBV and HCV serological markers.
    Miedouge M; Legrand-Abravanel F; Lalanne C; Saune K; Izopet J
    J Clin Virol; 2009 Feb; 44(2):134-7. PubMed ID: 19110466
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Bilirubin and metamizol do not interfere with the randox enzymatic creatinine test. An evaluation of a new enzymatic creatinine determination method.
    Harmoinen AP
    Eur J Clin Chem Clin Biochem; 1996 Dec; 34(12):975-6. PubMed ID: 8986403
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Enzymatic assays for creatinine: time for action.
    Panteghini M
    Scand J Clin Lab Invest Suppl; 2008; 241():84-8. PubMed ID: 18569972
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Glomerular filtration rate estimates based on serum creatinine level in healthy people: conventional Jaffe method versus calibrated Jaffe method at laboratories in Rasht.
    Badeli H; Sadeghi M; Khalili Pour E; Heidarzadeh A
    Iran J Kidney Dis; 2009 Jan; 3(1):45-9. PubMed ID: 19377259
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of new oxidation methods for the measurement of bilirubin on the aeroset clinical chemistry analyzer and comparison with methods on the Hitachi 717.
    Sturm E; Albrecht-Groos R; Seyfarth M
    Clin Lab; 2002; 48(7-8):401-5. PubMed ID: 12146574
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Enzymatic but not compensated Jaffe methods reach the desirable specifications of NKDEP at normal levels of creatinine. Results of the French multicentric evaluation.
    Boutten A; Bargnoux AS; Carlier MC; Delanaye P; Rozet E; Delatour V; Cavalier E; Hanser AM; Froissart M; Cristol JP; Piéroni L;
    Clin Chim Acta; 2013 Apr; 419():132-5. PubMed ID: 23415696
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Therapeutic concentrations of hydroxocobalamin interferes with several spectrophotometric assays on the Beckman Coulter DxC and AU680 chemistry analyzers.
    Ranjitkar P; Greene DN
    Clin Chim Acta; 2015 Oct; 450():110-4. PubMed ID: 26232160
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Comparison of the modified Jaffé method and an enzymatic method for the measurement of serum creatinine: practical consequences of a method change in the milieu of laboratory of oncologic clinical biology].
    Jaudon T; Séronie-Vivien S; Chatelut é ; Chanut C; Favre G
    Ann Biol Clin (Paris); 2000; 58(4):499-504. PubMed ID: 10932054
    [No Abstract]   [Full Text] [Related]  

  • 31. [Alpha 2 macroglobulin immunoturbidimetric assays (DakoCytomation reagents) on Roche Diagnostic analysers (Modular P, Cobas Integra). Application to FibroTest-Actic-Test].
    Piton A; Messous D; Imbert-Bismut F; Bergès J; Munteanu M; Poynard T; Hainque B
    Ann Biol Clin (Paris); 2005; 63(4):385-95. PubMed ID: 16061437
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development and evaluation of a reagent carrier with a new reaction sequence for the determination of creatinine in blood, plasma, serum and urine.
    Carstensen CA; Nagel R; Knoll E; Wisser H; Weidemann G; Riesen WF; Seiler D; Nagel D
    Eur J Clin Chem Clin Biochem; 1993 May; 31(5):335-46. PubMed ID: 8357943
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Determination of creatinine in the urine as a reference value of substances excreted by the kidney].
    Bauch K; Seitz W
    Z Gesamte Inn Med; 1985 Apr; 40(7):201-5. PubMed ID: 4002760
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A study of interferences in routine methods for creatinine measurement.
    Kenny D
    Scand J Clin Lab Invest Suppl; 1993; 212():43-7. PubMed ID: 8465153
    [TBL] [Abstract][Full Text] [Related]  

  • 35. New data on the intraindividual variation of cystatin C.
    Delanaye P; Cavalier E; Depas G; Chapelle JP; Krzesinski JM
    Nephron Clin Pract; 2008; 108(4):c246-8. PubMed ID: 18391572
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of serum creatinine method choice on estimated glomerular filtration rate determined by the abbreviated MDRD formula.
    McKillop DJ; Cairns B; Duly E; Van Drimmelen M; Ryan M
    Ann Clin Biochem; 2006 May; 43(Pt 3):220-2. PubMed ID: 16704759
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Different methods of creatinine measurement significantly affect MELD scores.
    Cholongitas E; Marelli L; Kerry A; Senzolo M; Goodier DW; Nair D; Thomas M; Patch D; Burroughs AK
    Liver Transpl; 2007 Apr; 13(4):523-9. PubMed ID: 17323365
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Comparison of two osmometers at the clinical chemistry laboratory].
    Belhouachi N; Jaisson S; Garnotel R; Gillery P
    Ann Biol Clin (Paris); 2007; 65(5):545-9. PubMed ID: 17913674
    [TBL] [Abstract][Full Text] [Related]  

  • 39. CLSI-based transference of the CALIPER database of pediatric reference intervals to Beckman Coulter DxC biochemical assays.
    Araújo PA; Thomas D; Sadeghieh T; Bevilacqua V; Chan MK; Chen Y; Randell E; Adeli K
    Clin Biochem; 2015 Sep; 48(13-14):870-80. PubMed ID: 26070714
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Serum creatinine determination by high performance liquid chromatography and five automated chemistry analyzers.
    Holmes EW; Oeser TH; Kahn SE; Bekeris L; Bermes EW
    Ann Clin Lab Sci; 1983; 13(6):503-10. PubMed ID: 6660833
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.