These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
285 related articles for article (PubMed ID: 20479656)
1. Left atrial appendage closure with Amplatzer Cardiac Plug for prevention of stroke in atrial fibrillation: in-vivo imaging. Leithäuser B; Broemel T; Park JW J Cardiovasc Med (Hagerstown); 2011 Mar; 12(3):209-11. PubMed ID: 20479656 [No Abstract] [Full Text] [Related]
2. Left atrial appendage occlusion using an amplatzer cardiac plug. Luykx M; Vermeersch P Acta Cardiol; 2010 Feb; 65(1):81-2. PubMed ID: 20306894 [No Abstract] [Full Text] [Related]
3. Safety of percutaneous left atrial appendage closure with the Amplatzer cardiac plug in patients with atrial fibrillation and contraindications to anticoagulation. Wiebe J; Bertog S; Franke J; Wettstein O; Lehn K; Hofmann I; Vaskelyte L; Sievert H Catheter Cardiovasc Interv; 2014 Apr; 83(5):796-802. PubMed ID: 24327462 [TBL] [Abstract][Full Text] [Related]
4. Cardiac CT and echocardiographic evaluation of peri-device flow after percutaneous left atrial appendage closure using the AMPLATZER cardiac plug device. Jaguszewski M; Manes C; Puippe G; Salzberg S; Müller M; Falk V; Lüscher T; Luft A; Alkadhi H; Landmesser U Catheter Cardiovasc Interv; 2015 Feb; 85(2):306-12. PubMed ID: 25205611 [TBL] [Abstract][Full Text] [Related]
5. Transcatheter closure of the left atrial appendage: A focused update on the Watchman closure device. Khalili H; Mansi IA; Hanzel GS; Banerjee S Catheter Cardiovasc Interv; 2018 Jul; 92(1):E28-E34. PubMed ID: 28471004 [No Abstract] [Full Text] [Related]
6. A novel approach to treat residual peridevice leakage after left-atrial appendage closure. Wunderlich N; Wilson N; Sievert H Catheter Cardiovasc Interv; 2013 Aug; 82(2):313-9. PubMed ID: 23629764 [TBL] [Abstract][Full Text] [Related]
7. Percutaneous closure of left atrial appendage to prevent embolic events in high-risk patients with chronic atrial fibrillation. Ussia GP; Mulè M; Cammalleri V; Scarabelli M; Barbanti M; Immè S; Mangiafico S; Marchese A; Galassi AR; Tamburino C Catheter Cardiovasc Interv; 2009 Aug; 74(2):217-22. PubMed ID: 19472361 [TBL] [Abstract][Full Text] [Related]
8. Percutaneous left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation and contraindication for anticoagulation. Grosset-Janin D; Barth E; Bertrand B; Detante O Rev Neurol (Paris); 2015 May; 171(5):426-32. PubMed ID: 25912470 [TBL] [Abstract][Full Text] [Related]
9. Imaging the left atrial appendage prior to, during, and after occlusion. Lockwood SM; Alison JF; Obeyesekere MN; Mottram PM JACC Cardiovasc Imaging; 2011 Mar; 4(3):303-6. PubMed ID: 21414580 [No Abstract] [Full Text] [Related]
10. Percutaneous left atrial appendage occlusion: Effect of device positioning on outcome. Wolfrum M; Attinger-Toller A; Shakir S; Gloekler S; Seifert B; Moschovitis A; Khattab A; Maisano F; Meier B; Nietlispach F Catheter Cardiovasc Interv; 2016 Oct; 88(4):656-664. PubMed ID: 27465268 [TBL] [Abstract][Full Text] [Related]
11. Incomplete left atrial appendage occlusion and thrombus formation after Watchman implantation treated with anticoagulation followed by further transcatheter closure with a second-generation Amplatzer Cardiac Plug (Amulet device). Lam SC; Bertog S; Sievert H Catheter Cardiovasc Interv; 2015 Feb; 85(2):321-7. PubMed ID: 24550125 [TBL] [Abstract][Full Text] [Related]
12. Successful Retrieval of a Dislodged Left Atrial Appendage Closure Device. Lee OH; Lee H; Kim JS JACC Cardiovasc Interv; 2017 Jan; 10(1):98-100. PubMed ID: 28057291 [No Abstract] [Full Text] [Related]
13. [Percutaneous closure of left atrial appendage in non-valvular atrial fibrillation--international and Hungarian experiences]. Fontos G; Andréka P; Temesvári A; Wéber D; Szatmári A Orv Hetil; 2010 May; 151(18):725-34. PubMed ID: 20409999 [TBL] [Abstract][Full Text] [Related]
14. Use of 3-Dimensional Models to Optimize Pre-Procedural Planning of Percutaneous Left Atrial Appendage Closure. Bieliauskas G; Otton J; Chow DHF; Sawaya FJ; Kofoed KF; Søndergaard L; De Backer O JACC Cardiovasc Interv; 2017 May; 10(10):1067-1070. PubMed ID: 28521927 [No Abstract] [Full Text] [Related]
15. Transcatheter closure of the left atrial appendage: initial experience with the Amplatzer cardiac plug device. Rodés-Cabau J; Champagne J; Bernier M Catheter Cardiovasc Interv; 2010 Aug; 76(2):186-92. PubMed ID: 20665857 [TBL] [Abstract][Full Text] [Related]
16. Cardiac computed tomography follow-up of left atrial appendage exclusion using the Amplatzer Cardiac Plug device. Poulter RS; Tang J; Jue J; Ibrahim R; Nicolaou S; Mayo J; Saw J Can J Cardiol; 2012; 28(1):119.e1-3. PubMed ID: 22129487 [TBL] [Abstract][Full Text] [Related]
17. Safety and Efficacy of Percutaneous Left Atrial Appendage Closure Without Preprocedural Imaging. Sanfilippo C; Frazzetto M; Costa G; Contrafatto C; Giacalone C; Tricomi G; Barbera C; Rizzo S; De Santis J; Sanfilippo M; Castania G; Di Salvo ME; Scandura S; Tamburino C; Barbanti M; Grasso C Circ Cardiovasc Interv; 2024 Jul; 17(7):e014183. PubMed ID: 38881462 [No Abstract] [Full Text] [Related]
18. Percutaneous Left Atrial Appendage Closure With the LAmbre Device for Stroke Prevention in Atrial Fibrillation: A Prospective, Multicenter Clinical Study. Huang H; Liu Y; Xu Y; Wang Z; Li Y; Cao K; Zhang S; Yang Y; Yang X; Huang D; Yu B; Su X; Wu L; Huang C JACC Cardiovasc Interv; 2017 Nov; 10(21):2188-2194. PubMed ID: 29122133 [TBL] [Abstract][Full Text] [Related]
19. Percutaneous closure of the left atrial appendage: a major step forward. Sievert H; Bayard YL JACC Cardiovasc Interv; 2009 Jul; 2(7):601-2. PubMed ID: 19628180 [No Abstract] [Full Text] [Related]
20. Closure of Left Atrial Appendage With Persistent Distal Thrombus Using an Amplatzer Amulet Occluder. Lange M; Bültel H; Weglage H; Löffeld P; Wichter T J Invasive Cardiol; 2016 Sep; 28(9):E75-6. PubMed ID: 27591691 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]