169 related articles for article (PubMed ID: 20483699)
1. A sparse representation method for magnetic resonance spectroscopy quantification.
Guo Y; Ruan S; Landré J; Constans JM
IEEE Trans Biomed Eng; 2010 Jul; 57(7):1620-7. PubMed ID: 20483699
[TBL] [Abstract][Full Text] [Related]
2. A mathematical assessment of the precision of parameters in measuring resonance spectra.
Golding EM; Golding RM
J Magn Reson; 1998 Dec; 135(2):380-405. PubMed ID: 9878467
[TBL] [Abstract][Full Text] [Related]
3. Quantification of MRS data in the frequency domain using a wavelet filter, an approximated Voigt lineshape model and prior knowledge.
Gillies P; Marshall I; Asplund M; Winkler P; Higinbotham J
NMR Biomed; 2006 Aug; 19(5):617-26. PubMed ID: 16927392
[TBL] [Abstract][Full Text] [Related]
4. Frequency-selective MRS data quantification with frequency prior knowledge.
Dologlou I; Van Huffel S; Van Ormondt D
J Magn Reson; 1998 Feb; 130(2):238-43. PubMed ID: 9500900
[TBL] [Abstract][Full Text] [Related]
5. Spectral fitting of NMR spectra using an alternating optimization method with a priori knowledge.
Bi Z; Bruner AP; Li J; Scott KN; Liu ZS; Stopka CB; Kim HW; Wilson DC
J Magn Reson; 1999 Sep; 140(1):108-19. PubMed ID: 10479553
[TBL] [Abstract][Full Text] [Related]
6. Exponential convergence rate (the spectral convergence) of the fast Padé transform for exact quantification in magnetic resonance spectroscopy.
Belkić D
Phys Med Biol; 2006 Dec; 51(24):6483-512. PubMed ID: 17148831
[TBL] [Abstract][Full Text] [Related]
7. Prior knowledge for time domain quantification of in vivo brain or liver 31P MR spectra.
Hamilton G; Patel N; Forton DM; Hajnal JV; Taylor-Robinson SD
NMR Biomed; 2003 May; 16(3):168-76. PubMed ID: 12884361
[TBL] [Abstract][Full Text] [Related]
8. Nonnegative matrix factorization for rapid recovery of constituent spectra in magnetic resonance chemical shift imaging of the brain.
Sajda P; Du S; Brown TR; Stoyanova R; Shungu DC; Mao X; Parra LC
IEEE Trans Med Imaging; 2004 Dec; 23(12):1453-65. PubMed ID: 15575404
[TBL] [Abstract][Full Text] [Related]
9. Extraction of multiple pure component 1H and 13C NMR spectra from two mixtures: novel solution obtained by sparse component analysis-based blind decomposition.
Kopriva I; Jerić I; Smrecki V
Anal Chim Acta; 2009 Oct; 653(2):143-53. PubMed ID: 19808106
[TBL] [Abstract][Full Text] [Related]
10. Signal denoising and ultrasonic flaw detection via overcomplete and sparse representations.
Zhang GM; Harvey DM; Braden DR
J Acoust Soc Am; 2008 Nov; 124(5):2963-72. PubMed ID: 19045784
[TBL] [Abstract][Full Text] [Related]
11. Wavelet domain non-linear filtering for MRI denoising.
Anand CS; Sahambi JS
Magn Reson Imaging; 2010 Jul; 28(6):842-61. PubMed ID: 20418039
[TBL] [Abstract][Full Text] [Related]
12. Spectral analysis of multichannel MRS data.
Sandgren N; Stoica P; Frigo FJ; Selén Y
J Magn Reson; 2005 Jul; 175(1):79-91. PubMed ID: 15949751
[TBL] [Abstract][Full Text] [Related]
13. A new general-purpose fully automatic baseline-correction procedure for 1D and 2D NMR data.
Cobas JC; Bernstein MA; Martín-Pastor M; Tahoces PG
J Magn Reson; 2006 Nov; 183(1):145-51. PubMed ID: 16891135
[TBL] [Abstract][Full Text] [Related]
14. A new FIR filter technique for solvent suppression in MRS signals.
Poullet JB; Pintelon R; Van Huffel S
J Magn Reson; 2009 Jan; 196(1):61-73. PubMed ID: 18952473
[TBL] [Abstract][Full Text] [Related]
15. [Frequency-domain quantification based on the singular value decomposition and frequency-selection for magnetic resonance spectra].
Men K; Quan H; Yang P; Cao T; Li W
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Apr; 27(2):249-52. PubMed ID: 20481295
[TBL] [Abstract][Full Text] [Related]
16. High resolution NMR spectroscopy using a recursive algorithm.
Nishiyama K; Mita T
IEEE Trans Biomed Eng; 1989 Feb; 36(2):222-31. PubMed ID: 2917767
[TBL] [Abstract][Full Text] [Related]
17. IRIS-HSVD algorithm for automatic quantitation of in vivo 31P MRS.
Wang X; Lee JH
J Magn Reson; 2009 Jan; 196(1):23-32. PubMed ID: 18926748
[TBL] [Abstract][Full Text] [Related]
18. Effect of sparse basis selection on ultrasonic signal representation.
Zhang GM; Harvey DM; Braden DR
Ultrasonics; 2006 Dec; 45(1-4):82-91. PubMed ID: 16930664
[TBL] [Abstract][Full Text] [Related]
19. New denoising scheme for magnetic resonance spectroscopy signals.
Ahmed OA
IEEE Trans Med Imaging; 2005 Jun; 24(6):809-16. PubMed ID: 15957602
[TBL] [Abstract][Full Text] [Related]
20. [Application of a modified method of wavelet noise removing to noisy ICP-AES spectra].
Ma XG; Zhang ZX
Guang Pu Xue Yu Guang Pu Fen Xi; 2003 Jun; 23(3):552-5. PubMed ID: 12953539
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]