These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 20489663)

  • 21. A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius--a biomechanical study.
    Windolf M; Schwieger K; Ockert B; Jupiter JB; Gradl G
    Injury; 2010 Feb; 41(2):204-9. PubMed ID: 19818959
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Surgical management of old vertical unstable pelvic fractures].
    Zhao MJ; Liu N; Lin HS; Xu RM
    Di Yi Jun Yi Da Xue Xue Bao; 2005 Jun; 25(6):739-41. PubMed ID: 15958327
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Internal fixation for pelvic posterior ring lesions].
    Zhang Q; Pang Q; Ge Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2006 Dec; 20(12):1214-6. PubMed ID: 17228685
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Sacroiliac screw fixation for tile B fractures.
    van den Bosch EW; van Zwienen CM; Hoek van Dijke GA; Snijders CJ; van Vugt AB
    J Trauma; 2003 Nov; 55(5):962-5. PubMed ID: 14608174
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures.
    Wolf JC; Weil WM; Hanel DP; Trumble TE
    J Hand Surg Am; 2006 Dec; 31(10):1578-86. PubMed ID: 17145376
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Minimally-invasive fixation for anterior pelvic ring disruptions.
    Cole PA; Dyskin EA; Gilbertson JA
    Injury; 2015 Sep; 46 Suppl 3():S27-34. PubMed ID: 26458296
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Standardized osteosynthesis techniques for the pelvic ring. Analysis of a patient sample and surgical technique].
    Pohlemann T; Kiessling B; Gänsslen A; Bosch U; Tscherne H
    Orthopade; 1992 Nov; 21(6):373-84. PubMed ID: 1475123
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The strength of iliosacral lag screws and transiliac bars in the fixation of vertically unstable pelvic injuries with sacral fractures.
    Gorczyca JT; Varga E; Woodside T; Hearn T; Powell J; Tile M
    Injury; 1996 Oct; 27(8):561-4. PubMed ID: 8994561
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Modification of spinal pedicle screw-plate fixation for bilateral pediatric pelvic ring injury in 2-year-old girl.
    Sa-ngasoongsong P; Sirisreetreerux N; Chanplakorn P; Woratanarat P; Suphachatwong C; Mulpruek P
    J Orthop Sci; 2015 Jul; 20(4):795-801. PubMed ID: 24390637
    [No Abstract]   [Full Text] [Related]  

  • 30. [Treatment of unstable pelvic fractures with minimally invasive internal fixation].
    Chen HW; Zhao GS; Ye ZM
    Zhongguo Gu Shang; 2010 Jul; 23(7):541-3. PubMed ID: 20701134
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Infra-acetabular corridor--technical tip for an additional screw placement to increase the fixation strength of acetabular fractures.
    Culemann U; Marintschev I; Gras F; Pohlemann T
    J Trauma; 2011 Jan; 70(1):244-6. PubMed ID: 21217495
    [No Abstract]   [Full Text] [Related]  

  • 32. Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques.
    Aminian A; Gao F; Fedoriw WW; Zhang LQ; Kalainov DM; Merk BR
    J Orthop Trauma; 2007 Sep; 21(8):544-8. PubMed ID: 17805021
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of olecranon plate fixation in osteoporotic bone: do current technologies and designs make a difference?
    Edwards SG; Martin BD; Fu RH; Gill JM; Nezhad MK; Orr JA; Ferrucci AM; Love JM; Booth R; Singer A; Hsieh AH
    J Orthop Trauma; 2011 May; 25(5):306-11. PubMed ID: 21464739
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comminuted talar neck fractures: a mechanical comparison of fixation techniques.
    Attiah M; Sanders DW; Valdivia G; Cooper I; Ferreira L; MacLeod MD; Johnson JA
    J Orthop Trauma; 2007 Jan; 21(1):47-51. PubMed ID: 17211269
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Reconstruction of the unstable pelvic fractures].
    Huang A; Pang Q; Zhang Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2005 Jul; 19(7):554-7. PubMed ID: 16108344
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Treatment of Tile B pelvic fracture by external fixator combined with limited internal fixation].
    Li K; Li Y; Li R; Lin Z; Lei G; Liao Q
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2010 Jun; 35(6):630-3. PubMed ID: 20622338
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Unstable fractures of pelvic girdle, problems of internal fixation using osteosynthesis material].
    Terbrüggen D; Dieterich H; Müller J
    Hefte Unfallheilkd; 1975; (124):215-7. PubMed ID: 1205903
    [No Abstract]   [Full Text] [Related]  

  • 38. Percutaneous pins versus volar plates for unstable distal radius fractures: a biomechanic study using a cadaver model.
    Knox J; Ambrose H; McCallister W; Trumble T
    J Hand Surg Am; 2007; 32(6):813-7. PubMed ID: 17606059
    [TBL] [Abstract][Full Text] [Related]  

  • 39. How much do locked screws add to the fixation of "hybrid" plate constructs in osteoporotic bone?
    Freeman AL; Tornetta P; Schmidt A; Bechtold J; Ricci W; Fleming M
    J Orthop Trauma; 2010 Mar; 24(3):163-9. PubMed ID: 20182252
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis.
    Doornink J; Fitzpatrick DC; Boldhaus S; Madey SM; Bottlang M
    J Trauma; 2010 Aug; 69(2):411-7. PubMed ID: 20699751
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.