These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 20491183)

  • 1. [Heart wall perforation after implantation of pacemaker - it happens].
    Oreziak A
    Kardiol Pol; 2010 Mar; 68(3):362-3. PubMed ID: 20491183
    [No Abstract]   [Full Text] [Related]  

  • 2. Delayed perforation of the right ventricle as a complication of permanent cardiac pacing - is following the guidelines always the right choice? Non-standard treatment - a case report and literature review.
    Rydlewska A; Małecka B; Zabek A; Klimeczek P; Lelakowski J; Pasowicz M; Czajkowski M; Kutarski A
    Kardiol Pol; 2010 Mar; 68(3):357-61. PubMed ID: 20411465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Value of the unipolar electrogram in the diagnosis of right ventricular perforation following pacemaker implantation.
    Macdonald J; Kelly D; Waktare J
    Heart; 2005 Feb; 91(2):228. PubMed ID: 15657243
    [No Abstract]   [Full Text] [Related]  

  • 4. [Prognostic value of the intracardiac electrocardiogram in the perforation of the free wall of the right ventricle caused by the electrode of a temporary pacemaker].
    López-Sendon J; Eizaguirre Pérez JA; Moreno Yangüela M; Gimeno de Carlos F; Novo Valledor L; Sarrión Guzmán M
    Rev Esp Cardiol; 1980; 33(3):209-15. PubMed ID: 7422986
    [No Abstract]   [Full Text] [Related]  

  • 5. [Perforation of the right ventricular wall by electrodes for permanent endocavitary stimulation].
    Haberka K; Pfitzner R; Sedziwy L
    Kardiol Pol; 1985; 28(8-9):541-6. PubMed ID: 4094289
    [No Abstract]   [Full Text] [Related]  

  • 6. [Ventricle perforation caused by intracardiac pacemaker electrodes].
    Wenzel KP
    Zentralbl Chir; 1971 Jan; 96(5):161-70. PubMed ID: 5553933
    [No Abstract]   [Full Text] [Related]  

  • 7. [Complication of endocardial stimulation: perforation of the right ventricle. Clinical and electrocardiographic aspects].
    Pistolese M; de Bellis F; Catalano V; Morabito A; Cittadini A; Richichi G; Staibano M
    Boll Soc Ital Cardiol; 1973; 18(10):980-4. PubMed ID: 4807034
    [No Abstract]   [Full Text] [Related]  

  • 8. Uneventful right ventricular perforation with displacement of a pacing lead into the left thorax.
    Boriani G; Biffi M; Martignani C
    J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):423-5. PubMed ID: 18503932
    [No Abstract]   [Full Text] [Related]  

  • 9. [On a case of perforation of the ventricular wall by a permanent intracavitary pacemaker catheter-electrode].
    Musella S; Viglietto A; Farzati B
    Rass Int Clin Ter; 1970 Sep; 50(18):1175-85. PubMed ID: 5476594
    [No Abstract]   [Full Text] [Related]  

  • 10. [Late perforation of the right ventricle by displacement of pacemaker electrodes (report of 2 cases)].
    Ramírez Isunza JM; Argüelles Mier MA; Esparza González JJ
    Arch Inst Cardiol Mex; 1982; 52(2):129-33. PubMed ID: 7103601
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Perforation of the heart during implantation of a transvenous pacemaker. A report on two cases].
    Meyer BH; Hugo JM; Anderson GW
    S Afr Med J; 1979 Oct; 56(18):734. PubMed ID: 505203
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Perforation of the right ventricular wall by temporary pacemaker wire.
    Gomes WJ; Buffolo E
    Tex Heart Inst J; 2004; 31(4):457. PubMed ID: 15745308
    [No Abstract]   [Full Text] [Related]  

  • 13. Late right ventricular perforation: a rare complication of a pacemaker implantation.
    Guardado J; Pereira VH; Fernandes M; Sanfins V; Monteiro V; Pinho P; Lourenço A
    Rev Port Cir Cardiotorac Vasc; 2012; 19(1):17-9. PubMed ID: 23641469
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Ventricular perforations caused by a pacemaker catheter (apropos of 7 cases)].
    Rodríguez García J; Perales Rodríguez N; Montero Castillo A; Schoendorff Marin G; Lozano Monton F
    Rev Esp Cardiol; 1976; 29(2):179-85. PubMed ID: 1273369
    [No Abstract]   [Full Text] [Related]  

  • 15. [Ventricular perforation by pacemaker leads: diagnosis by computed tomography].
    Awamleh García P; Talavera Calle P
    Radiologia; 2014; 56(5):472-4. PubMed ID: 23433630
    [No Abstract]   [Full Text] [Related]  

  • 16. Old is gold: tip electrograms to diagnose pacemaker lead perforation.
    Chandan K; Ponde C; Lokhandwala Y; Nandkumar K
    J Cardiovasc Electrophysiol; 2002 Oct; 13(10):1063. PubMed ID: 12435201
    [No Abstract]   [Full Text] [Related]  

  • 17. Delayed right-ventricular perforation by pacemaker lead; a rare complication in a 12-year-old girl.
    Aykan HH; Akın A; Ertuğrul İ; Karagöz T
    Turk Kardiyol Dern Ars; 2015 Mar; 43(2):185-7. PubMed ID: 25782125
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interventricular septal perforation as a rare complication of temporary transvenous pacemaker.
    Sahin T; Bildirici U; Celikyurt U; Tantan A; Kiliç T
    Anadolu Kardiyol Derg; 2008 Oct; 8(5):E34-5. PubMed ID: 18849216
    [No Abstract]   [Full Text] [Related]  

  • 19. [Perforation of the ventricle by intracardiac pacemaker electrodes].
    Kreutzberg B; Sobbe A; Meyer W; Düx A; Schaede A
    Thoraxchir Vask Chir; 1968 Feb; 16(1):82-90. PubMed ID: 5250433
    [No Abstract]   [Full Text] [Related]  

  • 20. [On the diagnosis and treatment of perforation of the cardiac wall in the course of permanent electrostimulation].
    Logi G; Baldari G; Rossi M; De Bellis F
    Acta Anaesthesiol; 1969; 20():Suppl 2:181-7. PubMed ID: 5408898
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.