These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 20492707)

  • 1. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.
    Windolf M; Klos K; Wähnert D; van der Pol B; Radtke R; Schwieger K; Jakob RP
    BMC Musculoskelet Disord; 2010 May; 11():95. PubMed ID: 20492707
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model.
    Gardner MJ; Brophy RH; Campbell D; Mahajan A; Wright TM; Helfet DL; Lorich DG
    J Orthop Trauma; 2005 Oct; 19(9):597-603. PubMed ID: 16247303
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ex vivo cyclic mechanical behaviour of 2.4 mm locking plates compared with 2.4 mm limited contact plates in a cadaveric diaphyseal gap model.
    Irubetagoyena I; Verset M; Palierne S; Swider P; Autefage A
    Vet Comp Orthop Traumatol; 2013; 26(6):479-88. PubMed ID: 24080774
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro biomechanical comparison of limited contat dynamic compression plate and locking compression plate.
    Aguila AZ; Manos JM; Orlansky AS; Todhunter RJ; Trotter EJ; Van der Meulen MC
    Vet Comp Orthop Traumatol; 2005; 18(4):220-6. PubMed ID: 16594390
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical Comparison of Locking Compression Plate and Limited Contact Dynamic Compression Plate Combined with an Intramedullary Rod in a Canine Femoral Fracture-Gap Model.
    Matres-Lorenzo L; Diop A; Maurel N; Boucton MC; Bernard F; Bernardé A
    Vet Surg; 2016 Apr; 45(3):319-26. PubMed ID: 26909507
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration.
    Windolf M; Maza ER; Gueorguiev B; Braunstein V; Schwieger K
    BMC Musculoskelet Disord; 2010 Aug; 11():172. PubMed ID: 20684752
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
    Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
    Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
    Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
    J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis.
    Bottlang M; Doornink J; Byrd GD; Fitzpatrick DC; Madey SM
    J Bone Joint Surg Am; 2009 Mar; 91(3):620-7. PubMed ID: 19255222
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws.
    Sod GA; Riggs LM; Mitchell CF; Martin GS
    Vet Surg; 2011 Jul; 40(5):571-8. PubMed ID: 21521241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Locking plate constructs benefit from interfragmentary lag screw fixation with decreased shear movements and more predictable fracture gap motion in simple fracture patterns.
    Märdian S; Schmölz W; Schaser KD; Duda GN; Heyland M
    Clin Biomech (Bristol, Avon); 2019 Dec; 70():89-96. PubMed ID: 31445402
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis.
    Doornink J; Fitzpatrick DC; Boldhaus S; Madey SM; Bottlang M
    J Trauma; 2010 Aug; 69(2):411-7. PubMed ID: 20699751
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model.
    Filipowicz D; Lanz O; McLaughlin R; Elder S; Werre S
    Vet Comp Orthop Traumatol; 2009; 22(4):270-7. PubMed ID: 19597629
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora.
    Goh CS; Santoni BG; Puttlitz CM; Palmer RH
    Am J Vet Res; 2009 Jan; 70(1):23-9. PubMed ID: 19119945
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mechanical Evaluation of Locking, Nonlocking, and Hybrid Plating Constructs Using a Locking Compression Plate in a Canine Synthetic Bone Model.
    Rowe-Guthrie KM; Markel MD; Bleedorn JA
    Vet Surg; 2015 Oct; 44(7):838-42. PubMed ID: 26287445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Schuhli augmentation of plate and screw fixation for humeral shaft fractures: a laboratory study.
    Simon JA; Dennis MG; Kummer FJ; Koval KJ
    J Orthop Trauma; 1999; 13(3):196-9. PubMed ID: 10206251
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.
    Mehin R; Jones B; Zhu Q; Broekhuyse H
    Can J Surg; 2009 Jun; 52(3):221-8. PubMed ID: 19503667
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods.
    Duplantier NL; Mitchell RJ; Zambrano S; Stone AC; Delgado DA; Lambert BS; Moreno MR; Harris JD; McCulloch PC; Lintner DM; Varner KE
    Am J Sports Med; 2018 Apr; 46(5):1220-1227. PubMed ID: 29466679
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures.
    Rausch S; Klos K; Wolf U; Gras M; Simons P; Brodt S; Windolf M; Gueorguiev B
    Int Orthop; 2014 Aug; 38(8):1705-10. PubMed ID: 24764050
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.