90 related articles for article (PubMed ID: 20494048)
1. Clinical experience with a novel thermosensitive temporary coronary artery occluder (LeGoo).
Bouchot O; Berger RL; Berne JP; Brunotte F; Brenot R
Ann Thorac Surg; 2010 Jun; 89(6):1912-7. PubMed ID: 20494048
[TBL] [Abstract][Full Text] [Related]
2. Randomized clinical trial comparing a thermosensitive polymer (LeGoo) with conventional vessel loops for temporary coronary artery occlusion during off-pump coronary artery bypass surgery.
Wimmer-Greinecker G; Bouchot O; Verhoye JP; Perrault LP; Börgermann J; Diegeler A; Van Garsse L; Rastan AJ
Ann Thorac Surg; 2011 Dec; 92(6):2177-83. PubMed ID: 22115228
[TBL] [Abstract][Full Text] [Related]
3. The use of reverse thermosensitive polymer (LeGoo) for temporary vessel occlusion in clampless peripheral vascular surgery.
Shalhoub J; Thapar A; Davies AH
Vasc Endovascular Surg; 2011 Jul; 45(5):422-5. PubMed ID: 21719551
[TBL] [Abstract][Full Text] [Related]
4. First results of clampless distal anastomosis in peripheral vascular bypass with LeGoo, a thermoreversible polymer.
Kretz B; Steinmetz E; Brenot R; Bouchot O
J Vasc Surg; 2012 Jun; 55(6):1821-5. PubMed ID: 22301211
[TBL] [Abstract][Full Text] [Related]
5. Effects of the novel polymer gel LeGoo on human internal thoracic arteries.
Winkler B; Müller-Schweinitzer E; Elezi F; Grussenmeyer T; Rueter F; Matt P; Konerding MA; Grapow MT; Eckstein FS
Ann Thorac Surg; 2011 Dec; 92(6):2235-9. PubMed ID: 22115233
[TBL] [Abstract][Full Text] [Related]
6. Off-pump coronary artery bypass graft surgery: a training course for novices and its learning curve.
Chen Y; Wan F
Thorac Cardiovasc Surg; 2009 Apr; 57(3):141-7. PubMed ID: 19330750
[TBL] [Abstract][Full Text] [Related]
7. Routine off-pump coronary artery bypass grafting is safe and feasible in high-risk patients with left main disease.
Emmert MY; Salzberg SP; Seifert B; Schurr UP; Hoerstrup SP; Reuthebuch O; Genoni M
Ann Thorac Surg; 2010 Apr; 89(4):1125-30. PubMed ID: 20338319
[TBL] [Abstract][Full Text] [Related]
8. Temporary coronary artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction in epicardial coronary arteries.
Bouchot O; Aubin MC; Carrier M; Cohn WE; Perrault LP
J Thorac Cardiovasc Surg; 2006 Nov; 132(5):1144-9. PubMed ID: 17059936
[TBL] [Abstract][Full Text] [Related]
9. Prospective randomized comparison of coronary bypass grafting with minimal extracorporeal circulation system (MECC) versus off-pump coronary surgery.
Mazzei V; Nasso G; Salamone G; Castorino F; Tommasini A; Anselmi A
Circulation; 2007 Oct; 116(16):1761-7. PubMed ID: 17875971
[TBL] [Abstract][Full Text] [Related]
10. Initial experience of an automated anastomotic distal device in off-pump CABG.
Kim KB; Cho KR; Choi JS; Ki EH
Heart Surg Forum; 2004; 7(5):E360-3. PubMed ID: 15799903
[TBL] [Abstract][Full Text] [Related]
11. On-pump versus off-pump coronary artery bypass surgery: a comparison of two consecutive series.
Uffman JK; Berry BE
J La State Med Soc; 2008; 160(4):204-7. PubMed ID: 18828462
[TBL] [Abstract][Full Text] [Related]
12. Hemostatic control of coronary arteries with poloxamer 407 reverse-thermal polymer during off-pump coronary artery bypass surgery in a pig model.
Cohn WE; Tuzun E; Simonak R; Baimbridge F
Innovations (Phila); 2007 Jan; 2(1):36-9. PubMed ID: 22436876
[TBL] [Abstract][Full Text] [Related]
13. How safe is it to train residents to perform off-pump coronary artery bypass surgery?
Asimakopoulos G; Karagounis AP; Valencia O; Rose D; Niranjan G; Chandrasekaran V
Ann Thorac Surg; 2006 Feb; 81(2):568-72. PubMed ID: 16427853
[TBL] [Abstract][Full Text] [Related]
14. Does the number of grafts influence surgeon choice and patient benefit of off-pump over conventional on-pump coronary artery revascularization in multivessel coronary artery disease?
Lattouf OM; Puskas JD; Thourani VH; Noora J; Kilgo PD; Guyton RA
Ann Thorac Surg; 2007 Nov; 84(5):1485-94; discussion 1494-5. PubMed ID: 17954050
[TBL] [Abstract][Full Text] [Related]
15. Initial experience with the enclose proximal aortic anastomosis device during off-pump coronary artery bypass: an alternative to aortic side clamping.
Boova RS; Trace C; Leshnower BG
Heart Surg Forum; 2006; 9(2):E607-11. PubMed ID: 16543162
[TBL] [Abstract][Full Text] [Related]
16. Disruption of graft endothelium correlates with early failure after off-pump coronary artery bypass surgery.
Manchio JV; Gu J; Romar L; Brown J; Gammie J; Pierson RN; Griffith B; Poston RS
Ann Thorac Surg; 2005 Jun; 79(6):1991-8. PubMed ID: 15919298
[TBL] [Abstract][Full Text] [Related]
17. Minimal extracorporeal circulation: an alternative for on-pump and off-pump coronary revascularization.
Puehler T; Haneya A; Philipp A; Wiebe K; Keyser A; Rupprecht L; Hirt S; Kobuch R; Diez C; Hilker M; Schmid C
Ann Thorac Surg; 2009 Mar; 87(3):766-72. PubMed ID: 19231386
[TBL] [Abstract][Full Text] [Related]
18. Which is first: left anterior descending artery anastomosis or right coronary artery anastomosis in off-pump coronary artery bypass grafting?
Yakut N; Tulukoğlu E; Emrecan B; Bayrak S; Yilik L; Göktoğan T; Gürbüz A
Heart Surg Forum; 2009 Oct; 12(5):E256-60. PubMed ID: 19833591
[TBL] [Abstract][Full Text] [Related]
19. Perioperative patency of coronary artery bypass grafting is not influenced by off-pump technique.
Onorati F; Olivito S; Mastroroberto P; di Virgilio A; Esposito A; Perrotti A; Renzulli A
Ann Thorac Surg; 2005 Dec; 80(6):2132-40. PubMed ID: 16305858
[TBL] [Abstract][Full Text] [Related]
20. Early and late outcome after off-pump coronary artery bypass graft surgery with coronary endarterectomy: a single-center 10-year experience.
Vohra HA; Kanwar R; Khan T; Dimitri WR
Ann Thorac Surg; 2006 May; 81(5):1691-6. PubMed ID: 16631657
[TBL] [Abstract][Full Text] [Related]