These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 20495750)

  • 21. Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.
    Willis AA; Kutsumi K; Zobitz ME; Cooney WP
    J Bone Joint Surg Am; 2006 Nov; 88(11):2411-7. PubMed ID: 17079398
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Distal ulna hook plate fixation for unstable distal ulna fracture associated with distal radius fracture.
    Lee SK; Kim KJ; Park JS; Choy WS
    Orthopedics; 2012 Sep; 35(9):e1358-64. PubMed ID: 22955402
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Volar fixed angle plate LCP 3.5 for dorsally distal radius fracture. About 24 cases].
    Pichon H; Chergaoui A; Jager S; Carpentier E; Jourdel F; Chaussard C; Saragaglia D
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Apr; 94(2):152-9. PubMed ID: 18420059
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Treatment of comminuted fracture of tibial plateau with ni-ti shape memory alloy bow-teeth screws combined with locking plate internal fixation].
    Wang YX; Zhang YT; Tang Y; Zhao X; Fu QG; Zhang X; Zhang CC
    Zhongguo Gu Shang; 2013 Jul; 26(7):601-4. PubMed ID: 24134033
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Long-term results of the surgical treatment of diaphyseal double fractures of the forearm in adults with plate or intramedullary nailing].
    Gaudenzi A; Bassi P; Mataloni L; Sartori E
    Arch Putti Chir Organi Mov; 1989; 37(2):407-16. PubMed ID: 2624548
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Intraosseous metal implants in orthopedics: A review.
    Rony L; Lancigu R; Hubert L
    Morphologie; 2018 Dec; 102(339):231-242. PubMed ID: 30348489
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Ni-Ti memory alloy clamp plate for fracture of short tubular bone.
    Yang PJ; Tao JC; Ge MZ; Yang QM; Yang HB; Sun Q
    Chin Med J (Engl); 1992 Apr; 105(4):312-5. PubMed ID: 1618014
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part I. Basic science and preclinical studies.
    Simon JA; Ricci JL; Di Cesare PE
    Am J Orthop (Belle Mead NJ); 1997 Oct; 26(10):665-71. PubMed ID: 9349887
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Percutaneous pins versus volar plates for unstable distal radius fractures: a biomechanic study using a cadaver model.
    Knox J; Ambrose H; McCallister W; Trumble T
    J Hand Surg Am; 2007; 32(6):813-7. PubMed ID: 17606059
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Multidirectional screw fixation in the treatment of distal radius fractures using angle-stable plates].
    Vlček M; Landor I; Višňa P; Vavřík P; Sindelářová J; Sosna A
    Acta Chir Orthop Traumatol Cech; 2011; 78(1):27-33. PubMed ID: 21375962
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results.
    Figl M; Weninger P; Liska M; Hofbauer M; Leixnering M
    Arch Orthop Trauma Surg; 2009 May; 129(5):661-9. PubMed ID: 19225792
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius.
    Imatani J; Noda T; Morito Y; Sato T; Hashizume H; Inoue H
    J Hand Surg Br; 2005 May; 30(2):220-5. PubMed ID: 15757779
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna.
    Ling HT; Kwan MK; Chua YP; Deepak AS; Ahmad TS
    Med J Malaysia; 2006 Dec; 61 Suppl B():8-12. PubMed ID: 17600986
    [TBL] [Abstract][Full Text] [Related]  

  • 34. More is not necessarily better. A biomechanical study on distal screw numbers in volar locking distal radius plates.
    Drobetz H; Weninger P; Grant C; Heal C; Muller R; Schuetz M; Pham M; Steck R
    Injury; 2013 Apr; 44(4):535-9. PubMed ID: 23127726
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A new mini-invasive technique in treating pediatric diaphyseal forearm fractures by bioabsorbable elastic stable intramedullary nailing: a preliminary technical report.
    Sinikumpu JJ; Keränen J; Haltia AM; Serlo W; Merikanto J
    Scand J Surg; 2013; 102(4):258-64. PubMed ID: 24056134
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates.
    Musgrave DS; Idler RS
    J Hand Surg Am; 2005 Jul; 30(4):743-9. PubMed ID: 16039367
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.
    Goldzak M; Simon P; Mittlmeier T; Chaussemier M; Chiergatti R
    Injury; 2014 Jan; 45 Suppl 1():S49-53. PubMed ID: 24219899
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Different methods of treating diaphyseal fractures of the radius and ulna in adults (author's transl)].
    Müller-Färber J; Decker S
    Unfallheilkunde; 1978 Mar; 81(3):103-9. PubMed ID: 644685
    [No Abstract]   [Full Text] [Related]  

  • 39. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].
    Zeman P; Zeman J; Matejka J; Koudela K
    Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):457-64. PubMed ID: 19150004
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Plate osteosynthesis of the radius. Own implant and technique].
    Sailer R; Pechlaner S; Gabl M
    Handchir Mikrochir Plast Chir; 1992 Nov; 24(6):284-91. PubMed ID: 1487187
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.