BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

223 related articles for article (PubMed ID: 20496717)

  • 1. [Determination of serum copper and zinc in different chemical forms by graphite furnace atomic absorption spectrometry with ethanol-EDTA precipitation method].
    Zhang Y; Li ZX; Li H; Peng L; Luo HJ; Li WQ; Luo WH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2010 Mar; 30(3):816-9. PubMed ID: 20496717
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Determination of trace free copper and zinc in serum samples by graphite furnace atomic absorption spectrometry after two-step precipitation of protein].
    Zhang Y; Lin ZX; Li WQ; Zhang QX; Li H; Luo HJ; Luo WH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2009 Oct; 29(10):2864-6. PubMed ID: 20038078
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasonic oscillation dialysis-graphite furnace atomic absorption spectrometer method for determination of "free" copper and exchangeable copper in serum.
    Zhang Y; Chen Y; Lin Z; Li Q; Chen Y; Peng L; Han M
    Clin Lab; 2014; 60(4):543-51. PubMed ID: 24779288
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous multielement analysis of microliter quantities of serum for copper, iron, and zinc by graphite furnace atomic absorption spectrometry.
    Lewis SA; O'Haver TC; Harnly JM
    Anal Chem; 1984 Aug; 56(9):1651-4. PubMed ID: 6486447
    [No Abstract]   [Full Text] [Related]  

  • 5. Determination of copper and zinc in serum by derivative atomic absorption spectrometry using the microsampling technique.
    Ji X; Ren J
    Analyst; 2002 Mar; 127(3):416-9. PubMed ID: 11996370
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Crosslinked carboxymethyl konjac glucomannan microcolumn preconcentration of trace lead, cadmium and copper in water samples and determination by graphite furnace atomic absorption spectrometry].
    Chen H; Shen M; Xue AF; Li SQ; Pan SY
    Guang Pu Xue Yu Guang Pu Fen Xi; 2009 May; 29(5):1422-6. PubMed ID: 19650505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Determination of indium in whole blood by graphite furnace atomic absorption spectrometry].
    He J; Liu F; Xiang Y; Li Z
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2015 Aug; 33(8):627-9. PubMed ID: 26653819
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct sample introduction of wines in graphite furnace atomic absorption spectrometry for the simultaneous determination of arsenic, cadmium, copper and lead content.
    Ajtony Z; Szoboszlai N; Suskó EK; Mezei P; György K; Bencs L
    Talanta; 2008 Jul; 76(3):627-34. PubMed ID: 18585331
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Direct determination of zinc in serum by Zeeman atomic absorption spectrometry with a graphite furnace.
    D'Haese PC; Lamberts LV; Vanheule AO; De Broe ME
    Clin Chem; 1992 Dec; 38(12):2439-43. PubMed ID: 1458581
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Zinc and copper determination in microsamples of serum by flow injection and atomic absorption spectroscopy.
    Rocks BF; Sherwood RA; Bayford LM; Riley C
    Ann Clin Biochem; 1982 Sep; 19(Pt 5):338-44. PubMed ID: 7137867
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Speciation analysis of trace elements Cu, Fe and Zn in serum by flame atomic absorption spectrophotometry].
    Hu J; Chang YM; Gao SB; Hai CX; Li JS; Xie XP
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Mar; 28(3):700-3. PubMed ID: 18536447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Direct determination of Cu and Pb in edible L-lysine by graphite furnace atomic absorption spectrometry].
    Shan F; Bian JS
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Jun; 22(3):480-2. PubMed ID: 12938341
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fast and direct screening of copper in micro-volumes of distilled alcoholic beverages by high-resolution continuum source graphite furnace atomic absorption spectrometry.
    Ajtony Z; Laczai N; Dravecz G; Szoboszlai N; Marosi Á; Marlok B; Streli C; Bencs L
    Food Chem; 2016 Dec; 213():799-805. PubMed ID: 27451250
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Process stability assessed by selecting Shewhart's psi statistical analysis technique of the influence of matrix modifier and furnace program in the optimization and precision of zinc determinations by graphite furnace atomic absorption spectroscopy.
    Al-Tufail M; Akram M; Haq A
    Res Commun Mol Pathol Pharmacol; 1999 Mar; 103(3):311-24. PubMed ID: 10509741
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Determination of trace metals in blood by "one-drop method" of flame atomic absorption spectrometry. 1. A simple system for continuous determination method of serum iron, copper and zinc (author's transl)].
    Makino T; Takahara K
    Rinsho Byori; 1980; 28(5):478-82. PubMed ID: 7392272
    [No Abstract]   [Full Text] [Related]  

  • 16. A micromethod for the analysis of zinc in plasma or serum by atomic absorption spectrophotometry using graphite furnace.
    Shaw JC; Bury AJ; Barber A; Mann L; Taylor A
    Clin Chim Acta; 1982 Feb; 118(2-3):229-39. PubMed ID: 7055982
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rapid ultramicro direct determination of erythrocyte lead concentration by atomic absorption spectrophotometry, with use of a graphite-tube furnace.
    Evenson MA; Pendergast DD
    Clin Chem; 1974 Feb; 20(2):163-71. PubMed ID: 4204884
    [No Abstract]   [Full Text] [Related]  

  • 18. Determination of zinc in serum, blood, and ultrafiltrate fluid from patients on hemofiltration by graphite furnace/atomic absorption spectroscopy or flow injection analysis/atomic absorption spectroscopy.
    de Blas OJ; Rodriguez RS; Mendez JH; Tomero JA; Gomez Bde L; Gonzalez SV
    J AOAC Int; 1994; 77(3):722-7. PubMed ID: 8012227
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Determination of trace metals in blood by "one-drop method" of flame atomic absorption spectrometry. 2. Direct determination method for copper or zinc in 10 microliter of serum (author's transl)].
    Makino T; Takahara K
    Rinsho Byori; 1980; 28(5):483-6. PubMed ID: 7392273
    [No Abstract]   [Full Text] [Related]  

  • 20. Determination of copper in urine by graphite furnace atomic absorption spectrometry.
    Halls DJ; Fell GS; Dunbar PM
    Clin Chim Acta; 1981 Jul; 114(1):21-7. PubMed ID: 7249371
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.