178 related articles for article (PubMed ID: 20502870)
1. Adaptive support ventilation versus conventional ventilation for total ventilatory support in acute respiratory failure.
Iotti GA; Polito A; Belliato M; Pasero D; Beduneau G; Wysocki M; Brunner JX; Braschi A; Brochard L; Mancebo J; Ranieri VM; Richard JC; Slutsky AS
Intensive Care Med; 2010 Aug; 36(8):1371-9. PubMed ID: 20502870
[TBL] [Abstract][Full Text] [Related]
2. Patient-ventilator interactions during partial ventilatory support: a preliminary study comparing the effects of adaptive support ventilation with synchronized intermittent mandatory ventilation plus inspiratory pressure support.
Tassaux D; Dalmas E; Gratadour P; Jolliet P
Crit Care Med; 2002 Apr; 30(4):801-7. PubMed ID: 11940749
[TBL] [Abstract][Full Text] [Related]
3. Safety and efficacy of a fully closed-loop control ventilation (IntelliVent-ASV®) in sedated ICU patients with acute respiratory failure: a prospective randomized crossover study.
Arnal JM; Wysocki M; Novotni D; Demory D; Lopez R; Donati S; Granier I; Corno G; Durand-Gasselin J
Intensive Care Med; 2012 May; 38(5):781-7. PubMed ID: 22460854
[TBL] [Abstract][Full Text] [Related]
4. Correlation between the %MinVol setting and work of breathing during adaptive support ventilation in patients with respiratory failure.
Wu CP; Lin HI; Perng WC; Yang SH; Chen CW; Huang YC; Huang KL
Respir Care; 2010 Mar; 55(3):334-41. PubMed ID: 20196884
[TBL] [Abstract][Full Text] [Related]
5. Comparison of pressure support ventilation and assist-control ventilation in the treatment of respiratory failure.
Tejeda M; Boix JH; Alvarez F; Balanzá R; Morales M
Chest; 1997 May; 111(5):1322-5. PubMed ID: 9149589
[TBL] [Abstract][Full Text] [Related]
6. Randomized crossover trial to compare driving pressures in a closed-loop and a conventional mechanical ventilation mode in pediatric patients.
Ceylan G; Topal S; Atakul G; Colak M; Soydan E; Sandal O; Sari F; Ağın H
Pediatr Pulmonol; 2021 Sep; 56(9):3035-3043. PubMed ID: 34293255
[TBL] [Abstract][Full Text] [Related]
7. Effects of implementing adaptive support ventilation in a medical intensive care unit.
Chen CW; Wu CP; Dai YL; Perng WC; Chian CF; Su WL; Huang YC
Respir Care; 2011 Jul; 56(7):976-83. PubMed ID: 21352661
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of adaptive support ventilation in paralysed patients and in a physical lung model.
Belliato M; Palo A; Pasero D; Iotti GA; Mojoli F; Braschi A
Int J Artif Organs; 2004 Aug; 27(8):709-16. PubMed ID: 15478542
[TBL] [Abstract][Full Text] [Related]
9. Adaptive Support Ventilation and Lung-Protective Ventilation in ARDS.
Baedorf Kassis EN; Bastos AB; Schaefer MS; Capers K; Hoenig B; Banner-Goodspeed V; Talmor D
Respir Care; 2022 Dec; 67(12):1542-1550. PubMed ID: 35973716
[TBL] [Abstract][Full Text] [Related]
10. The Effects of Automatic Inspiratory Rise Time and Flow Termination on Operation of Closed-Loop Ventilation.
Yang SH; Wu CP; Huang YCT; Peng CK
Respir Care; 2023 May; 68(5):669-675. PubMed ID: 37015812
[TBL] [Abstract][Full Text] [Related]
11. Automatic "respirator/weaning" with adaptive support ventilation: the effect on duration of endotracheal intubation and patient management.
Petter AH; Chioléro RL; Cassina T; Chassot PG; Müller XM; Revelly JP
Anesth Analg; 2003 Dec; 97(6):1743-1750. PubMed ID: 14633553
[TBL] [Abstract][Full Text] [Related]
12. A pilot prospective study on closed loop controlled ventilation and oxygenation in ventilated children during the weaning phase.
Jouvet P; Eddington A; Payen V; Bordessoule A; Emeriaud G; Gasco RL; Wysocki M
Crit Care; 2012 May; 16(3):R85. PubMed ID: 22591622
[TBL] [Abstract][Full Text] [Related]
13. Mask proportional assist vs pressure support ventilation in patients in clinically stable condition with chronic ventilatory failure.
Porta R; Appendini L; Vitacca M; Bianchi L; Donner CF; Poggi R; Ambrosino N
Chest; 2002 Aug; 122(2):479-88. PubMed ID: 12171820
[TBL] [Abstract][Full Text] [Related]
14. Closed-loop ventilation mode (IntelliVent®-ASV) in intensive care unit: a randomized trial.
Bialais E; Wittebole X; Vignaux L; Roeseler J; Wysocki M; Meyer J; Reychler G; Novotni D; Sottiaux T; Laterre PF; Hantson P
Minerva Anestesiol; 2016 Jun; 82(6):657-68. PubMed ID: 26957117
[TBL] [Abstract][Full Text] [Related]
15. Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure.
Pelosi P; Solca M; Ravagnan I; Tubiolo D; Ferrario L; Gattinoni L
Crit Care Med; 1996 Jul; 24(7):1184-8. PubMed ID: 8674333
[TBL] [Abstract][Full Text] [Related]
16. Determinants of tidal volumes with adaptive support ventilation: a multicenter observational study.
Dongelmans DA; Veelo DP; Bindels A; Binnekade JM; Koppenol K; Koopmans M; Korevaar JC; Kuiper MA; Schultz MJ
Anesth Analg; 2008 Sep; 107(3):932-7. PubMed ID: 18713908
[TBL] [Abstract][Full Text] [Related]
17. Adaptive support and pressure support ventilation behavior in response to increased ventilatory demand.
Jaber S; Sebbane M; Verzilli D; Matecki S; Wysocki M; Eledjam JJ; Brochard L
Anesthesiology; 2009 Mar; 110(3):620-7. PubMed ID: 19225395
[TBL] [Abstract][Full Text] [Related]
18. Adaptive support ventilation for complete ventilatory support in acute respiratory distress syndrome: a pilot, randomized controlled trial.
Agarwal R; Srinivasan A; Aggarwal AN; Gupta D
Respirology; 2013 Oct; 18(7):1108-15. PubMed ID: 23711230
[TBL] [Abstract][Full Text] [Related]
19. Tracheal gas insufflation reduces the tidal volume while PaCO2 is maintained constant.
Nakos G; Zakinthinos S; Kotanidou A; Tsagaris H; Roussos C
Intensive Care Med; 1994 Jul; 20(6):407-13. PubMed ID: 7798444
[TBL] [Abstract][Full Text] [Related]
20. Adaptive Support Ventilation Attenuates Ventilator Induced Lung Injury: Human and Animal Study.
Dai YL; Wu CP; Yang GG; Chang H; Peng CK; Huang KL
Int J Mol Sci; 2019 Nov; 20(23):. PubMed ID: 31766467
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]