BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 20505222)

  • 1. Scintillation dosimeter arrays using air core light guides: simulation and experiment.
    Naseri P; Suchowerska N; McKenzie DR
    Phys Med Biol; 2010 Jun; 55(12):3401-15. PubMed ID: 20505222
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.
    Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N
    Phys Med Biol; 2008 Jun; 53(11):3071-80. PubMed ID: 18490811
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A prototype scintillation dosimeter customized for small and dynamic megavoltage radiation fields.
    Lambert J; Yin Y; McKenzie DR; Law SH; Ralston A; Suchowerska N
    Phys Med Biol; 2010 Feb; 55(4):1115-26. PubMed ID: 20107251
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems.
    Paelinck L; Reynaert N; Thierens H; De Neve W; De Wagter C
    Phys Med Biol; 2005 May; 50(9):2055-69. PubMed ID: 15843736
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors.
    Sánchez-Doblado F; Capote R; Leal A; Roselló JV; Lagares JI; Arráns R; Hartmann GH
    Phys Med Biol; 2005 Mar; 50(5):959-70. PubMed ID: 15798268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode.
    Ishikawa M; Bengua G; Sutherland KL; Hiratsuka J; Katoh N; Shimizu S; Aoyama H; Fujita K; Yamazaki R; Horita K; Shirato H
    Phys Med Biol; 2009 Apr; 54(7):2079-92. PubMed ID: 19287089
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A plastic scintillation dosimeter for high dose rate brachytherapy.
    Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
    Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of electrodes on the photon energy deposition in CVD-diamond dosimeters studied with the Monte Carlo code PENELOPE.
    Górka B; Nilsson B; Fernández-Varea JM; Svensson R; Brahme A
    Phys Med Biol; 2006 Aug; 51(15):3607-23. PubMed ID: 16861769
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The determination of beam quality correction factors: Monte Carlo simulations and measurements.
    González-Castaño DM; Hartmann GH; Sánchez-Doblado F; Gómez F; Kapsch RP; Pena J; Capote R
    Phys Med Biol; 2009 Aug; 54(15):4723-41. PubMed ID: 19622853
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of the weighted CT dose index in modern multi-detector CT scanners.
    Perisinakis K; Damilakis J; Tzedakis A; Papadakis A; Theocharopoulos N; Gourtsoyiannis N
    Phys Med Biol; 2007 Nov; 52(21):6485-95. PubMed ID: 17951857
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
    Sikora M; Dohm O; Alber M
    Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The angular dependence and effective point of measurement of a cylindrical scintillation dosimeter with and without a radio-opaque marker for brachytherapy.
    Cartwright LE; Lambert J; McKenzie DR; Suchowerska N
    Phys Med Biol; 2009 Apr; 54(7):2217-27. PubMed ID: 19293468
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge.
    Liu PZ; Suchowerska N; Lambert J; Abolfathi P; McKenzie DR
    Phys Med Biol; 2011 Sep; 56(18):5805-21. PubMed ID: 21846934
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning.
    Babic S; McNiven A; Battista J; Jordan K
    Phys Med Biol; 2009 Apr; 54(8):2463-81. PubMed ID: 19336848
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements.
    Kim J; Hill R; Claridge Mackonis E; Kuncic Z
    Phys Med Biol; 2010 Feb; 55(3):783-97. PubMed ID: 20071763
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dose build-up behind air cavities for Co-60, 4, 6 and 8 MV. Measurements and Monte Carlo simulations.
    Behrens CF
    Phys Med Biol; 2006 Nov; 51(22):5937-50. PubMed ID: 17068375
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays.
    Hashimoto M; Tomita T; Sawada K; Fujibuchi T; Nishio T; Nakagawa K
    Rev Sci Instrum; 2009 Apr; 80(4):045101. PubMed ID: 19405685
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam.
    Mesbahi A
    Appl Radiat Isot; 2009 Jan; 67(1):55-60. PubMed ID: 18760613
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of PENELOPE Monte Carlo dose calculations with Fricke dosimeter and ionization chamber measurements in heterogeneous phantoms (18 MeV electron and 12 MV photon beams).
    Blazy L; Baltes D; Bordy JM; Cutarella D; Delaunay F; Gouriou J; Leroy E; Ostrowsky A; Beaumont S
    Phys Med Biol; 2006 Nov; 51(22):5951-65. PubMed ID: 17068376
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.