147 related articles for article (PubMed ID: 20515528)
1. A new pre-column derivatization method for determination of gabapentin in human serum by HPLC using UV detection.
Amini M; Rouini MR; Asad-Paskeh A; Shafiee A
J Chromatogr Sci; 2010; 48(5):358-61. PubMed ID: 20515528
[TBL] [Abstract][Full Text] [Related]
2. Validated HPLC method for the determination of gabapentin in human plasma using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene and its application to a pharmacokinetic study.
Jalalizadeh H; Souri E; Tehrani MB; Jahangiri A
J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jul; 854(1-2):43-7. PubMed ID: 17517538
[TBL] [Abstract][Full Text] [Related]
3. Simultaneous HPLC-F analysis of three recent antiepileptic drugs in human plasma.
Mercolini L; Mandrioli R; Amore M; Raggi MA
J Pharm Biomed Anal; 2010 Sep; 53(1):62-7. PubMed ID: 20363577
[TBL] [Abstract][Full Text] [Related]
4. Simultaneous quantification of levetiracetam and gabapentin in plasma by ultra-pressure liquid chromatography coupled with tandem mass spectrometry detection.
Juenke JM; Brown PI; Johnson-Davis KL; McMillin GA
Ther Drug Monit; 2011 Apr; 33(2):209-13. PubMed ID: 21297550
[TBL] [Abstract][Full Text] [Related]
5. Sensitive high-performance liquid chromatographic quantitation of gabapentin in human serum using liquid-liquid extraction and pre-column derivatization with 9-fluorenylmethyl chloroformate.
Bahrami G; Kiani A
J Chromatogr B Analyt Technol Biomed Life Sci; 2006 May; 835(1-2):123-6. PubMed ID: 16574508
[TBL] [Abstract][Full Text] [Related]
6. Determination of gabapentin in human plasma and urine by high-performance liquid chromatography with UV-vis detection.
Sagirli O; Cetin SM; Onal A
J Pharm Biomed Anal; 2006 Nov; 42(5):618-24. PubMed ID: 16822634
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous high-performance liquid chromatographic analysis of pregabalin, gabapentin and vigabatrin in human serum by precolumn derivatization with o-phtaldialdehyde and fluorescence detection.
Vermeij TA; Edelbroek PM
J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Oct; 810(2):297-303. PubMed ID: 15380728
[TBL] [Abstract][Full Text] [Related]
8. Sensitive microanalysis of gabapentin by high-performance liquid chromatography in human serum using pre-column derivatization with 4-chloro-7-nitrobenzofurazan: Application to a bioequivalence study.
Bahrami G; Mohammadi B
J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jun; 837(1-2):24-8. PubMed ID: 16644294
[TBL] [Abstract][Full Text] [Related]
9. Optimization of an HPLC method for determination of gabapentin in dosage forms through derivatization with 1-fluoro-2,4-dinitrobenzene.
Souri E; Jalalizadeh H; Shafiee A
Chem Pharm Bull (Tokyo); 2007 Oct; 55(10):1427-30. PubMed ID: 17917283
[TBL] [Abstract][Full Text] [Related]
10. High-performance liquid chromatographic method for the determination of gabapentin in human plasma.
Zhu Z; Neirinck L
J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Nov; 779(2):307-12. PubMed ID: 12361744
[TBL] [Abstract][Full Text] [Related]
11. Simple and sensitive liquid chromatographic method with fluorimetric detection for the analysis of gabapentin in human plasma.
Chung TC; Tai CT; Wu HL
J Chromatogr A; 2006 Jun; 1119(1-2):294-8. PubMed ID: 16426629
[TBL] [Abstract][Full Text] [Related]
12. Development and application of a validated HPLC method for the analysis of dissolution samples of gabapentin drug products.
Gupta A; Ciavarella AB; Sayeed VA; Khan MA; Faustino PJ
J Pharm Biomed Anal; 2008 Jan; 46(1):181-6. PubMed ID: 17935923
[TBL] [Abstract][Full Text] [Related]
13. Validated LC-MS-MS method for the determination of gabapentin in human plasma: application to a bioequivalence study.
Wattananat T; Akarawut W
J Chromatogr Sci; 2009; 47(10):868-71. PubMed ID: 19930796
[TBL] [Abstract][Full Text] [Related]
14. Development and application of a validated HPLC method for the determination of gabapentin and its major degradation impurity in drug products.
Ciavarella AB; Gupta A; Sayeed VA; Khan MA; Faustino PJ
J Pharm Biomed Anal; 2007 Apr; 43(5):1647-53. PubMed ID: 17275240
[TBL] [Abstract][Full Text] [Related]
15. Determination of Gabapentin in Human Plasma and Urine by Capillary Electrophoresis with Laser-Induced Fluorescence Detection.
Lin X; Cai Y; Yan J; Zhang L; Wu D; Li H
J Chromatogr Sci; 2015 Jul; 53(6):986-92. PubMed ID: 25352536
[TBL] [Abstract][Full Text] [Related]
16. Analysis of gabapentin in equine plasma with measurement uncertainty estimation by liquid chromatography-tandem mass spectrometry.
Liu Y; Uboh CE; Soma LR; Li X; Guan F; You Y; Rudy JA; Chen JW
J Anal Toxicol; 2011 Mar; 35(2):75-84. PubMed ID: 21396226
[TBL] [Abstract][Full Text] [Related]
17. Highly sensitive determination and validation of gabapentin in pharmaceutical preparations by HPLC with 4-fluoro-7-nitrobenzofurazan derivatization and fluorescence detection.
Ulu ST; Kel E
J Chromatogr Sci; 2011; 49(6):417-21. PubMed ID: 21682989
[TBL] [Abstract][Full Text] [Related]
18. Gas chromatography-electron ionization-mass spectrometry quantitation of valproic acid and gabapentin, using dried plasma spots, for therapeutic drug monitoring in in-home medical care.
Ikeda K; Ikawa K; Yokoshige S; Yoshikawa S; Morikawa N
Biomed Chromatogr; 2014 Dec; 28(12):1756-62. PubMed ID: 24889681
[TBL] [Abstract][Full Text] [Related]
19. Rapid quantification of gabapentin, pregabalin, and vigabatrin in human serum by ultraperformance liquid chromatography with mass-spectrometric detection.
Chahbouni A; Sinjewel A; den Burger JC; Vos RM; Wilhelm AJ; Veldkamp AI; Swart EL
Ther Drug Monit; 2013 Feb; 35(1):48-53. PubMed ID: 23188183
[TBL] [Abstract][Full Text] [Related]
20. Quantitative determination of vigabatrin and gabapentin in human serum by gas chromatography-mass spectrometry.
Borrey DC; Godderis KO; Engelrelst VI; Bernard DR; Langlois MR
Clin Chim Acta; 2005 Apr; 354(1-2):147-51. PubMed ID: 15748611
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]