537 related articles for article (PubMed ID: 20522155)
1. Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system.
Jilek C; Tzeis S; Reents T; Estner HL; Fichtner S; Ammar S; Wu J; Hessling G; Deisenhofer I; Kolb C
J Cardiovasc Electrophysiol; 2010 Oct; 21(10):1136-41. PubMed ID: 20522155
[TBL] [Abstract][Full Text] [Related]
2. Safety of remote magnetic navigation in patients with pacemakers and implanted cardioverter defibrillators.
Eitel C; Hindricks G; Sommer P; Wetzel U; Bollmann A; Gaspar T; Piorkowski C; Arya A
J Cardiovasc Electrophysiol; 2010 Oct; 21(10):1130-5. PubMed ID: 20455985
[TBL] [Abstract][Full Text] [Related]
3. Interference of remote magnetic catheter navigation and ablation with implanted devices for pacing and defibrillation.
Lüthje L; Vollmann D; Seegers J; Sohns C; Hasenfuss G; Zabel M
Europace; 2010 Nov; 12(11):1574-80. PubMed ID: 20810533
[TBL] [Abstract][Full Text] [Related]
4. Safety of electromagnetic articulography in patients with pacemakers and implantable cardioverter-defibrillators.
Joglar JA; Nguyen C; Garst DM; Katz WF
J Speech Lang Hear Res; 2009 Aug; 52(4):1082-7. PubMed ID: 19641084
[TBL] [Abstract][Full Text] [Related]
5. Novel robotic catheter manipulation system integrated with remote magnetic navigation for fully remote ablation of atrial tachyarrhythmias: a two-centre evaluation.
Nölker G; Gutleben KJ; Muntean B; Vogt J; Horstkotte D; Dabiri Abkenari L; Akca F; Szili-Torok T
Europace; 2012 Dec; 14(12):1715-8. PubMed ID: 22719063
[TBL] [Abstract][Full Text] [Related]
6. Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study.
Ryf S; Wolber T; Duru F; Luechinger R
Technol Health Care; 2008; 16(1):13-8. PubMed ID: 18334784
[TBL] [Abstract][Full Text] [Related]
7. Implications of pacemakers and implantable cardioverter defibrillators in urological practice.
Ubee SS; Kasi VS; Bello D; Manikandan R
J Urol; 2011 Oct; 186(4):1198-205. PubMed ID: 21849189
[TBL] [Abstract][Full Text] [Related]
8. Implanted devices and electromagnetic interference: case presentations and review.
Snow JS; Kalenderian D; Colasacco JA; Jadonath RL; Goldner BG; Cohen TJ
J Invasive Cardiol; 1995 Mar; 7(2):25-32. PubMed ID: 10155711
[TBL] [Abstract][Full Text] [Related]
9. Effects of electromagnetic interference on implanted cardiac devices and their management.
Yerra L; Reddy PC
Cardiol Rev; 2007; 15(6):304-9. PubMed ID: 18090066
[TBL] [Abstract][Full Text] [Related]
10. Early automatic remote detection of combined lead insulation defect and ICD damage.
Neuzil P; Taborsky M; Holy F; Wallbrueck K
Europace; 2008 May; 10(5):556-7. PubMed ID: 18227352
[TBL] [Abstract][Full Text] [Related]
11. Pacemakers and implantable cardioverter defibrillators--general and anesthetic considerations.
Rapsang AG; Bhattacharyya P
Braz J Anesthesiol; 2014; 64(3):205-14. PubMed ID: 24907883
[TBL] [Abstract][Full Text] [Related]
12. Letter regarding article by Roguin et al, "Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 t".
Chen-Scarabelli CA; Scarabelli TM
Circulation; 2005 Jun; 111(23):e390; author reply e391-2. PubMed ID: 15956143
[No Abstract] [Full Text] [Related]
13. Effects of surgical and endoscopic electrocautery on modern-day permanent pacemaker and implantable cardioverter-defibrillator systems.
Cheng A; Nazarian S; Spragg DD; Bilchick K; Tandri H; Mark L; Halperin H; Calkins H; Berger RD; Henrikson CA
Pacing Clin Electrophysiol; 2008 Mar; 31(3):344-50. PubMed ID: 18307631
[TBL] [Abstract][Full Text] [Related]
14. Implantable rhythm devices and electromagnetic interference: myth or reality?
Dyrda K; Khairy P
Expert Rev Cardiovasc Ther; 2008 Jul; 6(6):823-32. PubMed ID: 18570620
[TBL] [Abstract][Full Text] [Related]
15. Forces on cardiac implantable electronic devices during remote magnetic navigation.
Jilek C; Lennerz C; Stracke B; Badran H; Semmler V; Reents T; Ammar S; Fichtner S; Haller B; Hessling G; Deisenhofer I; Kolb C
Clin Res Cardiol; 2013 Mar; 102(3):185-92. PubMed ID: 23052333
[TBL] [Abstract][Full Text] [Related]
16. An in vitro evaluation of electromagnetic interference between implantable cardiac devices and ophthalmic laser systems.
Sher NA; Golben MP; Kresge K; Selznick L; Adabag S
Europace; 2011 Apr; 13(4):583-8. PubMed ID: 21252191
[TBL] [Abstract][Full Text] [Related]
17. Electromagnetic interference with cardiac pacemakers and implantable cardioverter-defibrillators from low-frequency electromagnetic fields in vivo.
Tiikkaja M; Aro AL; Alanko T; Lindholm H; Sistonen H; Hartikainen JE; Toivonen L; Juutilainen J; Hietanen M
Europace; 2013 Mar; 15(3):388-94. PubMed ID: 23125355
[TBL] [Abstract][Full Text] [Related]
18. Application of a clinical magnet over implantable cardioverter defibrillators: is it safe and useful?
Porres JM; Laviñeta E; Reviejo C; Brugada J
Pacing Clin Electrophysiol; 2008 Dec; 31(12):1641-4; dicussion 1645. PubMed ID: 19067820
[TBL] [Abstract][Full Text] [Related]
19. Magnetic resonance imaging in patients with implantable cardioverter-defibrillators and pacemakers.
Roguin A
J Am Coll Cardiol; 2009 Aug; 54(6):556-7. PubMed ID: 19643319
[No Abstract] [Full Text] [Related]
20. [Recommendations for protection against electromagnetic interference risk caused by pacemakers and implantable defibrillators in hospitals].
Santomauro M; Da Prato D; Ottaviano L; Borrelli A; Chiariello M
Ital Heart J Suppl; 2002 Apr; 3(4):440-5. PubMed ID: 12025389
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]