205 related articles for article (PubMed ID: 20529980)
1. Patient characteristics and anesthetic technique are additive but not synergistic predictors of successful motor evoked potential monitoring.
Deiner SG; Kwatra SG; Lin HM; Weisz DJ
Anesth Analg; 2010 Aug; 111(2):421-5. PubMed ID: 20529980
[TBL] [Abstract][Full Text] [Related]
2. Highlights of anesthetic considerations for intraoperative neuromonitoring.
Deiner S
Semin Cardiothorac Vasc Anesth; 2010 Mar; 14(1):51-3. PubMed ID: 20472627
[TBL] [Abstract][Full Text] [Related]
3. The efficacy of motor evoked potentials in fixed sagittal imbalance deformity correction surgery.
Lieberman JA; Lyon R; Feiner J; Hu SS; Berven SH
Spine (Phila Pa 1976); 2008 Jun; 33(13):E414-24. PubMed ID: 18520928
[TBL] [Abstract][Full Text] [Related]
4. Alarm criteria for motor-evoked potentials: what's wrong with the "presence-or-absence" approach?
Calancie B; Molano MR
Spine (Phila Pa 1976); 2008 Feb; 33(4):406-14. PubMed ID: 18277873
[TBL] [Abstract][Full Text] [Related]
5. Impact of multimodal intraoperative monitoring during surgery for spine deformity and potential risk factors for neurological monitoring changes.
Feng B; Qiu G; Shen J; Zhang J; Tian Y; Li S; Zhao H; Zhao Y
J Spinal Disord Tech; 2012 Jun; 25(4):E108-14. PubMed ID: 22367467
[TBL] [Abstract][Full Text] [Related]
6. Differential rates of false-positive findings in transcranial electric motor evoked potential monitoring when using inhalational anesthesia versus total intravenous anesthesia during spine surgeries.
Tamkus AA; Rice KS; Kim HL
Spine J; 2014 Aug; 14(8):1440-6. PubMed ID: 24209393
[TBL] [Abstract][Full Text] [Related]
7. Transcranial motor-evoked potentials combined with response recording through compound muscle action potential as the sole modality of spinal cord monitoring in spinal deformity surgery.
Hsu B; Cree AK; Lagopoulos J; Cummine JL
Spine (Phila Pa 1976); 2008 May; 33(10):1100-6. PubMed ID: 18449044
[TBL] [Abstract][Full Text] [Related]
8. Progressive suppression of motor evoked potentials during general anesthesia: the phenomenon of "anesthetic fade".
Lyon R; Feiner J; Lieberman JA
J Neurosurg Anesthesiol; 2005 Jan; 17(1):13-9. PubMed ID: 15632537
[TBL] [Abstract][Full Text] [Related]
9. Intraoperative motor-evoked potential monitoring in scoliosis surgery: comparison of desflurane/nitrous oxide with propofol total intravenous anesthetic regimens.
Lo YL; Dan YF; Tan YE; Nurjannah S; Tan SB; Tan CT; Raman S
J Neurosurg Anesthesiol; 2006 Jul; 18(3):211-4. PubMed ID: 16799350
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of reliability of post-tetanic motor-evoked potential monitoring during spinal surgery under general anesthesia.
Hayashi H; Kawaguchi M; Yamamoto Y; Inoue S; Koizumi M; Ueda Y; Takakura Y; Furuya H
Spine (Phila Pa 1976); 2008 Dec; 33(26):E994-E1000. PubMed ID: 19092611
[TBL] [Abstract][Full Text] [Related]
11. [Motor evoked potentials].
Kawaguchi M; Furuya H
Masui; 2006 Mar; 55(3):294-301. PubMed ID: 16541778
[TBL] [Abstract][Full Text] [Related]
12. Analysis of motor and somatosensory evoked potentials during thoracic and thoracoabdominal aortic aneurysm repair.
Keyhani K; Miller CC; Estrera AL; Wegryn T; Sheinbaum R; Safi HJ
J Vasc Surg; 2009 Jan; 49(1):36-41. PubMed ID: 18829232
[TBL] [Abstract][Full Text] [Related]
13. Risk factors for false positive transcranial motor evoked potential monitoring alerts during surgical treatment of cervical myelopathy.
Kim DH; Zaremski J; Kwon B; Jenis L; Woodard E; Bode R; Banco RJ
Spine (Phila Pa 1976); 2007 Dec; 32(26):3041-6. PubMed ID: 18091499
[TBL] [Abstract][Full Text] [Related]
14. Significance of intraoperative motor function monitoring using transcranial electrical motor evoked potentials (MEP) in patients with spinal and cranial lesions near the motor pathways.
Krammer MJ; Wolf S; Schul DB; Gerstner W; Lumenta CB
Br J Neurosurg; 2009 Feb; 23(1):48-55. PubMed ID: 19234909
[TBL] [Abstract][Full Text] [Related]
15. High-frequency stimulation restored motor-evoked potentials to the baseline level in the upper extremities but not in the lower extremities under sevoflurane anesthesia in spine surgery.
Shida Y; Shida C; Hiratsuka N; Kaji K; Ogata J
J Neurosurg Anesthesiol; 2012 Apr; 24(2):113-20. PubMed ID: 22036875
[TBL] [Abstract][Full Text] [Related]
16. Four-limb muscle motor evoked potential and optimized somatosensory evoked potential monitoring with decussation assessment: results in 206 thoracolumbar spine surgeries.
Macdonald DB; Al Zayed Z; Al Saddigi A
Eur Spine J; 2007 Nov; 16 Suppl 2(Suppl 2):S171-87. PubMed ID: 17638028
[TBL] [Abstract][Full Text] [Related]
17. The effects of the neuromuscular blockade levels on amplitudes of posttetanic motor-evoked potentials and movement in response to transcranial stimulation in patients receiving propofol and fentanyl anesthesia.
Yamamoto Y; Kawaguchi M; Hayashi H; Horiuchi T; Inoue S; Nakase H; Sakaki T; Furuya H
Anesth Analg; 2008 Mar; 106(3):930-4, table of contents. PubMed ID: 18292442
[TBL] [Abstract][Full Text] [Related]
18. The effect of age on motor evoked potentials in children under propofol/isoflurane anesthesia.
Lieberman JA; Lyon R; Feiner J; Diab M; Gregory GA
Anesth Analg; 2006 Aug; 103(2):316-21, table of contents. PubMed ID: 16861411
[TBL] [Abstract][Full Text] [Related]
19. Intraoperative multimodality monitoring in adult spinal deformity: analysis of a prospective series of one hundred two cases with independent evaluation.
Quraishi NA; Lewis SJ; Kelleher MO; Sarjeant R; Rampersaud YR; Fehlings MG
Spine (Phila Pa 1976); 2009 Jun; 34(14):1504-12. PubMed ID: 19483667
[TBL] [Abstract][Full Text] [Related]
20. Upper-limb somatosensory evoked potential monitoring in lumbosacral spine surgery: a prognostic marker for position-related ulnar nerve injury.
Chung I; Glow JA; Dimopoulos V; Walid MS; Smisson HF; Johnston KW; Robinson JS; Grigorian AA
Spine J; 2009 Apr; 9(4):287-95. PubMed ID: 18684675
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]