These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 20531605)

  • 1. Extreme ultraviolet reflectance degradation of aluminum and silicon from surface oxidation.
    Scott ML; Arendt PN; Cameron BJ; Saber JM; Newnam BE
    Appl Opt; 1988 Apr; 27(8):1503-7. PubMed ID: 20531605
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optical constants of aluminum films in the extreme ultraviolet interval of 82-77 nm.
    Larruquert JI; Méndez JA; Aznárez JA
    Appl Opt; 1996 Oct; 35(28):5692-7. PubMed ID: 21127577
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Solar absorptivity and thermal emissivity of aluminum coated with silicon oxide films prepared by evaporation of silicon monoxide.
    Bradford AP; Hass G; Heaney JB; Triolo JJ
    Appl Opt; 1970 Feb; 9(2):339-44. PubMed ID: 20076191
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Wavelength dependence of angle-resolved scattering in the extreme-ultraviolet-visible region.
    Mattsson L; Ingers J; Bennett JM
    Appl Opt; 1994 Jun; 33(16):3523-32. PubMed ID: 20885738
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calculated reflectance of alurminurm-overcoated iridium in the vacuum ultraviolet from 500 A to 2000 A.
    Hass G; Hunter WR
    Appl Opt; 1967 Dec; 6(12):2097-100. PubMed ID: 20062366
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermal emissivity and solar absorptivity of aluminum coated with double layers of aluminum oxide and silicon oxide.
    Hass G; Ramsey JB; Heaney JB; Triolo JJ
    Appl Opt; 1971 Jun; 10(6):1296-8. PubMed ID: 20111108
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Amorphous silicon carbide coatings for extreme ultraviolet optics.
    Kortright JB; Windt DL
    Appl Opt; 1988 Jul; 27(14):2841-6. PubMed ID: 20531849
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Far-ultraviolet reflectance measurements and optical constants of unoxidized aluminum films.
    Larruquert JI; Méndez JA; Aznárez JA
    Appl Opt; 1995 Aug; 34(22):4892-9. PubMed ID: 21052330
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Proton-induced contaminant film effects on ultraviolet reflecting mirrors.
    Gillette RB; Kenyon BA
    Appl Opt; 1971 Mar; 10(3):545-51. PubMed ID: 20094488
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Far-UV reflectance of UHV-prepared Al films and its degradation after exposure to O(2).
    Larruquert JI; Méndez JA; Aznárez JA
    Appl Opt; 1994 Jun; 33(16):3518-22. PubMed ID: 20885737
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhanced low-temperature CO oxidation on a stepped platinum surface for oxygen pressures above 10(-5) Torr.
    Lewis HD; Burnett DJ; Gabelnick AM; Fischer DA; Gland JL
    J Phys Chem B; 2005 Nov; 109(46):21847-57. PubMed ID: 16853838
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of oxygen atom bombardment on the reflectance of silicon carbide mirrors in the extreme ultraviolet region.
    Seely JF; Holland GE; Hunter WR; McCoy RP; Dymond KF; Corson M
    Appl Opt; 1993 Apr; 32(10):1805-10. PubMed ID: 20820315
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reflectance, Solar Absorptivity, and Thermal Emissivity of SiO(2)-Coated Aluminum.
    Hass G; Ramsey JB; Heaney JB; Triolo JJ
    Appl Opt; 1969 Feb; 8(2):275-81. PubMed ID: 20072214
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multiple angle ellipsometric analysis of surface layers and surface layer contaminants.
    Pedinoff ME; Stafsudd OM
    Appl Opt; 1982 Feb; 21(3):518-21. PubMed ID: 20372487
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Further studies on MgF(2)-overcoated aluminum mirrors with highest reflectance in the vacuum ultraviolet.
    Canfield LR; Hass G; Waylonis JE
    Appl Opt; 1966 Jan; 5(1):45-9. PubMed ID: 20048784
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reflectance of Aluminum Overcoated with MgF(2) and LiF in the Wavelength Region from 1600 A to 300 A at Various Angles of Incidence.
    Hunter WR; Osantowski JF; Hass G
    Appl Opt; 1971 Mar; 10(3):540-4. PubMed ID: 20094487
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thin aluminum filters for use on the Apollo Telescope Mount XUV spectrographs.
    Schumacher RJ; Hunter WR
    Appl Opt; 1977 Apr; 16(4):904-8. PubMed ID: 20168610
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reflectance and durability of Ag mirrors coated with thin layers of Al(2)O(3) plus reactively deposited silicon oxide.
    Hass G; Heaney JB; Herzig H; Osantowski JF; Triolo JJ
    Appl Opt; 1975 Nov; 14(11):2639-44. PubMed ID: 20155078
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Further studies on LiF-overcoated aluminum mirrors with highest reflectance in the vacuum ultraviolet.
    Cox JT; Hass G; Waylonis JE
    Appl Opt; 1968 Aug; 7(8):1535-40. PubMed ID: 20068835
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of monolayer formation on aluminum-doped zinc oxide thin films.
    Rhodes CL; Lappi S; Fischer D; Sambasivan S; Genzer J; Franzen S
    Langmuir; 2008 Jan; 24(2):433-40. PubMed ID: 18069859
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.