These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 20535482)

  • 21. Changes in corneal biomechanical properties after 24 hours of continuous intraocular pressure monitoring using a contact lens sensor.
    Morales-Fernandez L; Garcia-Bella J; Martinez-de-la-Casa JM; Sanchez-Jean R; Saenz-Frances F; Arriola-Villalobos P; Perucho L; Santos-Bueso E; Garcia-Feijoo J
    Can J Ophthalmol; 2018 Jun; 53(3):236-241. PubMed ID: 29784159
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor.
    Mansouri K; Medeiros FA; Weinreb RN
    Clin Exp Ophthalmol; 2015 Dec; 43(9):787-95. PubMed ID: 26152693
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma.
    Mansouri K; Medeiros FA; Tafreshi A; Weinreb RN
    Arch Ophthalmol; 2012 Dec; 130(12):1534-9. PubMed ID: 23229696
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Association Between 24-Hour Intraocular Pressure Monitored With Contact Lens Sensor and Visual Field Progression in Older Adults With Glaucoma.
    De Moraes CG; Mansouri K; Liebmann JM; Ritch R;
    JAMA Ophthalmol; 2018 Jul; 136(7):779-785. PubMed ID: 29800011
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ambulatory 24-h intraocular pressure monitoring in the management of glaucoma.
    Mansouri K; Weinreb RN
    Curr Opin Ophthalmol; 2015 May; 26(3):214-20. PubMed ID: 25784109
    [TBL] [Abstract][Full Text] [Related]  

  • 26. 24-hour intraocular pressure fluctuation monitoring using an ocular telemetry Sensor: tolerability and functionality in healthy subjects.
    De Smedt S; Mermoud A; Schnyder C
    J Glaucoma; 2012; 21(8):539-44. PubMed ID: 21602707
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Technical construction, calibration and results with a new intraocular pressure sensor with telemetric transmission].
    Hille K; Draeger J; Eggers T; Stegmaier P
    Klin Monbl Augenheilkd; 2001 May; 218(5):376-80. PubMed ID: 11417341
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Using 24-hr ocular dimensional profile recorded with a sensing contact lens to identify primary open-angle glaucoma patients with intraocular pressure constantly below the diagnostic threshold.
    Shioya S; Higashide T; Tsuchiya S; Simon-Zoula S; Varidel T; Cerboni S; Mansouri K; Sugiyama K
    Acta Ophthalmol; 2020 Dec; 98(8):e1017-e1023. PubMed ID: 32339402
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor.
    Bozkurt B; Okudan N; Belviranli M; Oflaz AB
    Indian J Ophthalmol; 2019 Jan; 67(1):89-94. PubMed ID: 30574900
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Contact glass tonometer].
    Kanngiesser H; Robert Y; Dekker P
    Ophthalmologe; 1996 Oct; 93(5):549-51. PubMed ID: 9004878
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tolerability and Functionality of a Wireless 24-Hour Ocular Telemetry Sensor in African American Glaucoma Patients.
    Marando CM; Mansouri K; Kahook MY; Seibold LK
    J Glaucoma; 2019 Feb; 28(2):119-124. PubMed ID: 30688840
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The influence of electromagnetic radiation on the measurement behaviour of the triggerfish® contact lens sensor.
    Rabensteiner DF; Rabensteiner J; Faschinger C
    BMC Ophthalmol; 2018 Dec; 18(1):338. PubMed ID: 30587178
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of Machine Learning on Contact Lens Sensor-Derived Parameters for the Diagnosis of Primary Open-angle Glaucoma.
    Martin KR; Mansouri K; Weinreb RN; Wasilewicz R; Gisler C; Hennebert J; Genoud D;
    Am J Ophthalmol; 2018 Oct; 194():46-53. PubMed ID: 30053471
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Continuous intraocular pressure measurement over several days with the Codman Microsensor--a case report].
    Höh H; Schwanengel M
    Klin Monbl Augenheilkd; 1999 Sep; 215(3):186-96. PubMed ID: 10528285
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Continuous intraocular pressure measurement: First results with a pressure-sensitive contact lens].
    Hediger A; Kniestedt C; Zweifel S; Knecht P; Funk J; Kanngiesser H
    Ophthalmologe; 2009 Dec; 106(12):1111-5. PubMed ID: 19756646
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The sensing contact lens.
    Bertsch A; Leonardi M; Renaud P
    Med Device Technol; 2006 Jun; 17(5):19-21. PubMed ID: 16903384
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of variations of corneal physiology on novel non-invasive intraocular pressure monitoring soft contact lens.
    Campigotto A; Ralhan A; Helgason R; Campbell RJ; Lai Y
    Biomed Microdevices; 2021 Mar; 23(1):16. PubMed ID: 33725182
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Twenty-four-hour intraocular pressure patterns in patients with thyroid eye disease.
    Parekh AS; Mansouri K; Weinreb RN; Tafreshi A; Korn BS; Kikkawa DO
    Clin Exp Ophthalmol; 2015 Mar; 43(2):108-14. PubMed ID: 25132194
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Continuous 24-hour intraocular pressure monitoring for glaucoma--time for a paradigm change.
    Mansouri K; Weinreb R
    Swiss Med Wkly; 2012; 142():w13545. PubMed ID: 22457163
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Advances in diagnostic applications for monitoring intraocular pressure in Glaucoma: A review.
    Sanchez I; Martin R
    J Optom; 2019; 12(4):211-221. PubMed ID: 31405810
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.