These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 20541338)

  • 1. MRI-guided breast biopsy at 3T using a dedicated large core biopsy set: feasibility and initial results.
    Meeuwis C; Mann RM; Mus RD; Winkel A; Boetes C; Barentsz JO; Veltman J
    Eur J Radiol; 2011 Aug; 79(2):257-61. PubMed ID: 20541338
    [TBL] [Abstract][Full Text] [Related]  

  • 2. MRI-guided intervention for breast lesions using the freehand technique in a 3.0-T closed-bore MRI scanner: feasibility and initial results.
    Choi HY; Kim SM; Jang M; Yun BL; Kim SW; Kang E; Park SY; Moon WK; Ko ES
    Korean J Radiol; 2013; 14(2):171-8. PubMed ID: 23482868
    [TBL] [Abstract][Full Text] [Related]  

  • 3. MR-guided stereotactic breast biopsy: technical aspects and preliminary results.
    Panizza P; De Cobelli F; De Gaspari A; Gusmini S; Zanello A; Del Maschio A
    Radiol Med; 2003 Sep; 106(3):232-44. PubMed ID: 14612844
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results.
    Noebauer-Huhmann IM; Amann G; Krssak M; Panotopoulos J; Szomolanyi P; Weber M; Czerny C; Breitenseher M; Grabner G; Bogner W; Nemec S; Dominkus M; Funovics P; Windhager R; Trattnig S
    Eur Radiol; 2015 Jul; 25(7):2041-8. PubMed ID: 25577522
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet.
    Meeuwis C; Peters NH; Mali WP; Gallardo AM; van Hillegersberg R; Schipper ME; van den Bosch MA
    Eur J Radiol; 2007 May; 62(2):283-8. PubMed ID: 17218074
    [TBL] [Abstract][Full Text] [Related]  

  • 6. MRI-guided breast biopsy: clinical experience with 14-gauge stainless steel core biopsy needle.
    Chen X; Lehman CD; Dee KE
    AJR Am J Roentgenol; 2004 Apr; 182(4):1075-80. PubMed ID: 15039191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapy.
    Yakar D; Hambrock T; Huisman H; Hulsbergen-van de Kaa CA; van Lin E; Vergunst H; Hoeks CM; van Oort IM; Witjes JA; Barentsz JO; Fütterer JJ
    Invest Radiol; 2010 Mar; 45(3):121-5. PubMed ID: 20065860
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Breast lesion localization: a freehand, interactive MR imaging-guided technique.
    Daniel BL; Birdwell RL; Ikeda DM; Jeffrey SS; Black JW; Block WF; Sawyer-Glover AM; Glover GH; Herfkens RJ
    Radiology; 1998 May; 207(2):455-63. PubMed ID: 9577495
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Freehand 3T MR-guided vacuum-assisted breast biopsy (VAB): a five-year experience.
    Gristina L; Rescinito G; Garlaschi A; Tosto S; Cevasco L; Calabrese M
    Acta Radiol; 2018 May; 59(5):540-545. PubMed ID: 28862025
    [TBL] [Abstract][Full Text] [Related]  

  • 10. MRI-guided vacuum-assisted breast biopsy performed at 3 T with a 9-gauge needle: preliminary experience.
    Dogan BE; Le-Petross CH; Stafford JR; Atkinson N; Whitman GJ
    AJR Am J Roentgenol; 2012 Nov; 199(5):W651-3. PubMed ID: 23096211
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [MRI-controlled intervention in suspected lesions of the breast].
    Vosshenrich R; Fischer U; Grabbe E
    Geburtshilfe Frauenheilkd; 1996 Apr; 56(4):173-6. PubMed ID: 8682281
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.
    Hambrock T; Fütterer JJ; Huisman HJ; Hulsbergen-vandeKaa C; van Basten JP; van Oort I; Witjes JA; Barentsz JO
    Invest Radiol; 2008 Oct; 43(10):686-94. PubMed ID: 18791410
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is ultrasonography-guided modified coaxial core biopsy of the breast a better technique?
    Wong CS; Chu YC; Wong KW; Yeung TH; Ma KF
    Hong Kong Med J; 2009 Aug; 15(4):246-8. PubMed ID: 19652229
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nonsurgical management of high-risk lesions diagnosed at core needle biopsy: can malignancy be ruled out safely with breast MRI?
    Linda A; Zuiani C; Furlan A; Lorenzon M; Londero V; Girometti R; Bazzocchi M
    AJR Am J Roentgenol; 2012 Feb; 198(2):272-80. PubMed ID: 22268168
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic resonance-guided biopsy of the prostate: feasibility, technique, and clinical applications.
    Yakar D; Hambrock T; Hoeks C; Barentsz JO; Fütterer JJ
    Top Magn Reson Imaging; 2008 Dec; 19(6):291-5. PubMed ID: 19512851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improving outcomes of screening breast MRI with practice evolution: initial clinical experience with 3T compared to 1.5T.
    Lourenco AP; Donegan L; Khalil H; Mainiero MB
    J Magn Reson Imaging; 2014 Mar; 39(3):535-9. PubMed ID: 23720144
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.
    Zamecnik P; Schouten MG; Krafft AJ; Maier F; Schlemmer HP; Barentsz JO; Bock M; Fütterer JJ
    Radiology; 2014 Dec; 273(3):879-86. PubMed ID: 25061830
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-risk breast lesions at imaging-guided needle biopsy: usefulness of MRI for treatment decision.
    Londero V; Zuiani C; Linda A; Girometti R; Bazzocchi M; Sardanelli F
    AJR Am J Roentgenol; 2012 Aug; 199(2):W240-50. PubMed ID: 22826427
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 1.5-T magnetic resonance-guided transgluteal biopsies of the prostate in patients with clinically suspected prostate cancer: technique and feasibility.
    Bodelle B; Naguib NN; Schulz B; Eichler K; Müller C; Hansmann ML; Hammerstingl R; Hübner F; Vogl TJ; Zangos S
    Invest Radiol; 2013 Jun; 48(6):458-63. PubMed ID: 23385402
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MRI-Guided percutaneous biopsy of breast lesions: materials, techniques, success rates, and management in patients with suspected radiologic-pathologic mismatch.
    Floery D; Helbich TH
    Magn Reson Imaging Clin N Am; 2006 Aug; 14(3):411-25, viii. PubMed ID: 17098182
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.