These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 20544916)

  • 1. Polyneuropathy caused by cobalt-chromium metallosis after total hip replacement.
    Ikeda T; Takahashi K; Kabata T; Sakagoshi D; Tomita K; Yamada M
    Muscle Nerve; 2010 Jul; 42(1):140-3. PubMed ID: 20544916
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Systemic toxicity related to metal hip prostheses.
    Bradberry SM; Wilkinson JM; Ferner RE
    Clin Toxicol (Phila); 2014; 52(8):837-47. PubMed ID: 25132471
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fatal cobalt toxicity after total hip arthroplasty revision for fractured ceramic components.
    Fox KA; Phillips TM; Yanta JH; Abesamis MG
    Clin Toxicol (Phila); 2016 Nov; 54(9):874-877. PubMed ID: 27491800
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Abrasive wear and metallosis associated with cross-linked polyethylene in total hip arthroplasty.
    O'Brien ST; Burnell CD; Hedden DR; Brandt JM
    J Arthroplasty; 2013 Jan; 28(1):197.e17-21. PubMed ID: 22770854
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Metal ion levels decrease after revision for metallosis arising from large-diameter metal-on-metal hip arthroplasty.
    Ebreo D; Khan A; El-Meligy M; Armstrong C; Peter V
    Acta Orthop Belg; 2011 Dec; 77(6):777-81. PubMed ID: 22308623
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture--a case report.
    Hasegawa M; Sudo A; Uchida A
    Acta Orthop; 2006 Oct; 77(5):833-5. PubMed ID: 17068720
    [No Abstract]   [Full Text] [Related]  

  • 7. Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty.
    Maezawa K; Nozawa M; Hirose T; Matsuda K; Yasuma M; Shitoto K; Kurosawa H
    Arch Orthop Trauma Surg; 2002 Jun; 122(5):283-7. PubMed ID: 12070648
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
    Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
    Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements.
    Lhotka C; Szekeres T; Steffan I; Zhuber K; Zweymüller K
    J Orthop Res; 2003 Mar; 21(2):189-95. PubMed ID: 12568948
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Acetabular cup malalignment after total hip resurfacing arthroplasty: a case for elective revision?
    Mai MC; Milbrandt JC; Hulsen J; Allan DG
    Orthopedics; 2009 Nov; 32(11):853. PubMed ID: 19902880
    [TBL] [Abstract][Full Text] [Related]  

  • 11. MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips.
    Toms AP; Marshall TJ; Cahir J; Darrah C; Nolan J; Donell ST; Barker T; Tucker JK
    Clin Radiol; 2008 Jan; 63(1):49-58. PubMed ID: 18068790
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner.
    Zywiel MG; Brandt JM; Overgaard CB; Cheung AC; Turgeon TR; Syed KA
    Bone Joint J; 2013 Jan; 95-B(1):31-7. PubMed ID: 23307670
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Systemic allergic dermatitis caused by cobalt and cobalt toxicity from a metal on a metal hip replacement.
    Wong CC; Nixon RL
    Contact Dermatitis; 2014 Aug; 71(2):113-4. PubMed ID: 25040712
    [No Abstract]   [Full Text] [Related]  

  • 14. Serum chromium levels before and after revision surgery for loosened metal-on-metal total hip arthroplasty.
    Maezawa K; Nozawa M; Matsuda K; Sugimoto M; Shitoto K; Kurosawa H
    J Arthroplasty; 2009 Jun; 24(4):549-53. PubMed ID: 18534450
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Allergic cobalt reaction (metallosis) following knee arthroplasty with vitallium endoprosthesis ad modum Walldius (author's transl)].
    Wigren A; Fischer T
    Z Orthop Ihre Grenzgeb; 1975 Apr; 113(2):273-4. PubMed ID: 1136557
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Unusual presentation of cobalt hypersensitivity in a patient with a metal-on-metal bearing in total hip arthroplasty.
    Perumal V; Alkire M; Swank ML
    Am J Orthop (Belle Mead NJ); 2010 May; 39(5):E39-41. PubMed ID: 20567745
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metallosis in a Dog as a Long-Term Complication Following Total Hip Arthroplasty.
    DiVincenzo MJ; Frydman GH; Kowaleski MP; Vanderburg CR; Lai B; Oura TJ; Jennings SH
    Vet Pathol; 2017 Sep; 54(5):828-831. PubMed ID: 28651457
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cobalt, chromium and molybdenum ions kinetics in the human body: data gained from a total hip replacement with massive third body wear of the head and neuropathy by cobalt intoxication.
    Pazzaglia UE; Apostoli P; Congiu T; Catalani S; Marchese M; Zarattini G
    Arch Orthop Trauma Surg; 2011 Sep; 131(9):1299-308. PubMed ID: 21298277
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty.
    Oldenburg M; Wegner R; Baur X
    J Arthroplasty; 2009 Aug; 24(5):825.e15-20. PubMed ID: 18835128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Catastrophic wear in a metal-on-ceramic total hip arthroplasty.
    Valentí JR; Del Río J; Amillo S
    J Arthroplasty; 2007 Sep; 22(6):920-2. PubMed ID: 17826286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.