234 related articles for article (PubMed ID: 20550982)
1. A resistive mesh phantom for assessing the performance of EIT systems.
Gagnon H; Cousineau M; Adler A; Hartinger AE
IEEE Trans Biomed Eng; 2010 Sep; 57(9):2257-66. PubMed ID: 20550982
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of EIT system performance.
Yasin M; Böhm S; Gaggero PO; Adler A
Physiol Meas; 2011 Jul; 32(7):851-65. PubMed ID: 21646713
[TBL] [Abstract][Full Text] [Related]
3. [A data acquisition system for induced current electrical impedance tomography].
Xiang H; Dong X; Qin M; You F; Shi X; Fu F; Liu R; Ma J
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Aug; 22(4):819-23. PubMed ID: 16156281
[TBL] [Abstract][Full Text] [Related]
4. Accounting for hardware imperfections in EIT image reconstruction algorithms.
Hartinger AE; Gagnon H; Guardo R
Physiol Meas; 2007 Jul; 28(7):S13-27. PubMed ID: 17664631
[TBL] [Abstract][Full Text] [Related]
5. Multi-frequency EIT system with radially symmetric architecture: KHU Mark1.
Oh TI; Woo EJ; Holder D
Physiol Meas; 2007 Jul; 28(7):S183-96. PubMed ID: 17664635
[TBL] [Abstract][Full Text] [Related]
6. A high frequency electrical impedance tomograph using distributed parallel input channels.
Jossinet J; Trillaud C; Risacher F; McAdams ET
Med Prog Technol; 1993-1994; 19(4):167-72. PubMed ID: 8052171
[TBL] [Abstract][Full Text] [Related]
7. Systematic errors of EIT systems determined by easily-scalable resistive phantoms.
Hahn G; Just A; Dittmar J; Hellige G
Physiol Meas; 2008 Jun; 29(6):S163-72. PubMed ID: 18544805
[TBL] [Abstract][Full Text] [Related]
8. Statistical estimation of resistance/conductance by electrical impedance tomography measurements.
Demidenko E; Hartov A; Paulsen K
IEEE Trans Med Imaging; 2004 Jul; 23(7):829-38. PubMed ID: 15250635
[TBL] [Abstract][Full Text] [Related]
9. Reconstruction of conductivity changes and electrode movements based on EIT temporal sequences.
Dai T; Gómez-Laberge C; Adler A
Physiol Meas; 2008 Jun; 29(6):S77-88. PubMed ID: 18544802
[TBL] [Abstract][Full Text] [Related]
10. Comparison of applied and induced current electrical impedance tomography.
Tanguay LF; Gagnon H; Guardo R
IEEE Trans Biomed Eng; 2007 Sep; 54(9):1643-9. PubMed ID: 17867356
[TBL] [Abstract][Full Text] [Related]
11. Imaging of conductivity changes and electrode movement in EIT.
Soleimani M; Gómez-Laberge C; Adler A
Physiol Meas; 2006 May; 27(5):S103-13. PubMed ID: 16636402
[TBL] [Abstract][Full Text] [Related]
12. A broadband high-frequency electrical impedance tomography system for breast imaging.
Halter RJ; Hartov A; Paulsen KD
IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):650-9. PubMed ID: 18270001
[TBL] [Abstract][Full Text] [Related]
13. Estimation of anomaly location and size using electrical impedance tomography.
Kwon O; Yoon JR; Seo JK; Woo EJ; Cho YG
IEEE Trans Biomed Eng; 2003 Jan; 50(1):89-96. PubMed ID: 12617528
[TBL] [Abstract][Full Text] [Related]
14. A method for modelling and optimizing an electrical impedance tomography system.
Hartinger AE; Gagnon H; Guardo R
Physiol Meas; 2006 May; 27(5):S51-64. PubMed ID: 16636420
[TBL] [Abstract][Full Text] [Related]
15. Comparison of a new integrated current source with the modified Howland circuit for EIT applications.
Hong H; Rahal M; Demosthenous A; Bayford RH
Physiol Meas; 2009 Oct; 30(10):999-1007. PubMed ID: 19706961
[TBL] [Abstract][Full Text] [Related]
16. Calibration methods for a multi-channel multi-frequency EIT system.
Oh TI; Lee KH; Kim SM; Koo H; Woo EJ; Holder D
Physiol Meas; 2007 Oct; 28(10):1175-88. PubMed ID: 17906386
[TBL] [Abstract][Full Text] [Related]
17. Feature-space assessment of electrical impedance tomography coregistered with computed tomography in detecting multiple contrast targets.
Krishnan K; Liu J; Kohli K
Med Phys; 2014 Jun; 41(6):061903. PubMed ID: 24877814
[TBL] [Abstract][Full Text] [Related]
18. Performance evaluation of five types of Ag/AgCl bio-electrodes for cerebral electrical impedance tomography.
Xu S; Dai M; Xu C; Chen C; Tang M; Shi X; Dong X
Ann Biomed Eng; 2011 Jul; 39(7):2059-67. PubMed ID: 21455793
[TBL] [Abstract][Full Text] [Related]
19. Parametric EIT for monitoring cardiac stroke volume.
Zlochiver S; Freimark D; Arad M; Adunsky A; Abboud S
Physiol Meas; 2006 May; 27(5):S139-46. PubMed ID: 16636406
[TBL] [Abstract][Full Text] [Related]
20. A multi-frequency EIT system design based on telecommunication signal processors.
Robitaille N; Guardo R; Maurice I; Hartinger AE; Gagnon H
Physiol Meas; 2009 Jun; 30(6):S57-71. PubMed ID: 19491440
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]