BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

252 related articles for article (PubMed ID: 20551186)

  • 1. Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study.
    Pache G; Krauss B; Strohm P; Saueressig U; Blanke P; Bulla S; Schäfer O; Helwig P; Kotter E; Langer M; Baumann T
    Radiology; 2010 Aug; 256(2):617-24. PubMed ID: 20551186
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dose reduction does not affect detection of bone marrow lesions with dual-energy CT virtual noncalcium technique.
    Pache G; Bulla S; Baumann T; Bayer J; Reising K; Strohm P; Langer M; Blanke P
    Acad Radiol; 2012 Dec; 19(12):1539-45. PubMed ID: 23020888
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dual-Energy CT-based Display of Bone Marrow Edema in Osteoporotic Vertebral Compression Fractures: Impact on Diagnostic Accuracy of Radiologists with Varying Levels of Experience in Correlation to MR Imaging.
    Kaup M; Wichmann JL; Scholtz JE; Beeres M; Kromen W; Albrecht MH; Lehnert T; Boettcher M; Vogl TJ; Bauer RW
    Radiology; 2016 Aug; 280(2):510-9. PubMed ID: 26928067
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images.
    Cao JX; Wang YM; Kong XQ; Yang C; Wang P
    Eur J Radiol; 2015 Jun; 84(6):1109-15. PubMed ID: 25816992
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diagnostic performance of dual-energy CT for the detection of traumatic bone marrow lesions in the ankle: comparison with MR imaging.
    Guggenberger R; Gnannt R; Hodler J; Krauss B; Wanner GA; Csuka E; Payne B; Frauenfelder T; Andreisek G; Alkadhi H
    Radiology; 2012 Jul; 264(1):164-73. PubMed ID: 22570505
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Color-coded virtual non-calcium dual-energy CT for the depiction of bone marrow edema in patients with acute knee trauma: a multireader diagnostic accuracy study.
    Booz C; Nöske J; Lenga L; Martin SS; Yel I; Eichler K; Gruber-Rouh T; Huizinga N; Albrecht MH; Vogl TJ; Wichmann JL
    Eur Radiol; 2020 Jan; 30(1):141-150. PubMed ID: 31350586
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of Bone Marrow Edema in Nondisplaced Hip Fractures: Utility of a Virtual Noncalcium Dual-Energy CT Application.
    Kellock TT; Nicolaou S; Kim SSY; Al-Busaidi S; Louis LJ; O'Connell TW; Ouellette HA; McLaughlin PD
    Radiology; 2017 Sep; 284(3):798-805. PubMed ID: 28301779
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Vertebral Compression Fractures: Third-Generation Dual-Energy CT for Detection of Bone Marrow Edema at Visual and Quantitative Analyses.
    Petritsch B; Kosmala A; Weng AM; Krauss B; Heidemeier A; Wagner R; Heintel TM; Gassenmaier T; Bley TA
    Radiology; 2017 Jul; 284(1):161-168. PubMed ID: 28240561
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bone marrow edema in vertebral compression fractures: detection with dual-energy CT.
    Wang CK; Tsai JM; Chuang MT; Wang MT; Huang KY; Lin RM
    Radiology; 2013 Nov; 269(2):525-33. PubMed ID: 23801776
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic accuracy of dual-energy CT for detection of bone marrow lesions in the subacutely injured knee with MRI as reference method.
    Björkman AS; Koskinen SK; Lindblom M; Persson A
    Acta Radiol; 2020 Jun; 61(6):749-759. PubMed ID: 31581782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of dual-energy CT and virtual non-calcium techniques to evaluate post-traumatic bone bruises in knees in the subacute setting.
    Ai S; Qu M; Glazebrook KN; Liu Y; Rhee PC; Leng S; McCollough CH
    Skeletal Radiol; 2014 Sep; 43(9):1289-95. PubMed ID: 24913554
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual-energy computed tomographic virtual noncalcium algorithm for detection of bone marrow edema in acute fractures: early experiences.
    Reagan AC; Mallinson PI; O'Connell T; McLaughlin PD; Krauss B; Munk PL; Nicolaou S; Ouellette HA
    J Comput Assist Tomogr; 2014; 38(5):802-5. PubMed ID: 24834889
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A preliminary study of dual-source computed tomography dual energy imaging in the diagnosis of acute traumatic bone marrow lesions in spine].
    Gu L; Hong G; Liang J; Xu Q; Du Z; Liu X
    Zhonghua Yi Xue Za Zhi; 2014 Oct; 94(39):3088-90. PubMed ID: 25549685
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures: Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography.
    Frellesen C; Azadegan M; Martin SS; Otani K; DʼAngelo T; Booz C; Eichler K; Panahi B; Kaup M; Bauer RW; Vogl TJ; Wichmann JL
    Invest Radiol; 2018 Jul; 53(7):409-416. PubMed ID: 29489560
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of bone marrow edema in osteonecrosis of the femoral head using virtual noncalcium dual-energy computed tomography.
    Zuo T; Chen Y; Zheng H; Jia X; Bao Y; Wang Y; Li L; Huang X
    Eur J Radiol; 2021 Jun; 139():109681. PubMed ID: 33819804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Added value of color-coded virtual non-calcium dual-energy CT in the detection of acute knee fractures in non-radiology inexpert readers.
    Yang SJ; Jeon JY; Lee SW; Jeong YM
    Eur J Radiol; 2020 Aug; 129():109112. PubMed ID: 32526668
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis.
    Kosmala A; Weng AM; Heidemeier A; Krauss B; Knop S; Bley TA; Petritsch B
    Radiology; 2018 Jan; 286(1):205-213. PubMed ID: 28799843
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single- source volume CT scanner.
    Diekhoff T; Hermann KG; Pumberger M; Hamm B; Putzier M; Fuchs M
    Eur J Radiol; 2017 Feb; 87():59-65. PubMed ID: 28065376
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dual-Energy Computed Tomography Virtual Noncalcium Technique in Diagnosing Osteoporosis: Correlation With Quantitative Computed Tomography.
    Liu Z; Zhang Y; Liu Z; Kong J; Huang D; Zhang X; Jiang Y
    J Comput Assist Tomogr; 2021 May-Jun 01; 45(3):452-457. PubMed ID: 34297514
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Traumatic bone marrow edema of the calcaneus: Evaluation of color-coded virtual non-calcium dual-energy CT in a multi-reader diagnostic accuracy study.
    Booz C; Nöske J; Albrecht MH; Lenga L; Martin SS; Wichmann JL; Huizinga NA; Eichler K; Nour-Eldin NA; Vogl TJ; Yel I
    Eur J Radiol; 2019 Sep; 118():207-214. PubMed ID: 31439244
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.