417 related articles for article (PubMed ID: 20554436)
1. Adsorption of bovine serum albumin on CoCrMo surface: effect of temperature and protein concentration.
Valero Vidal C; Olmo Juan A; Igual Muñoz A
Colloids Surf B Biointerfaces; 2010 Oct; 80(1):1-11. PubMed ID: 20554436
[TBL] [Abstract][Full Text] [Related]
2. Albumin adsorption on CoCrMo alloy surfaces.
Yan Y; Yang H; Su Y; Qiao L
Sci Rep; 2015 Dec; 5():18403. PubMed ID: 26673525
[TBL] [Abstract][Full Text] [Related]
3. Interfacial Behavior of beta-Lactoglobulin at a Stainless Steel Surface: An Electrochemical Impedance Spectroscopy Study.
Omanovic S; Roscoe SG
J Colloid Interface Sci; 2000 Jul; 227(2):452-460. PubMed ID: 10873333
[TBL] [Abstract][Full Text] [Related]
4. Studies on the conformational change of adsorbed BSA onto a moderately hydrophobic surface at different denaturant concentrations and surface coverages.
Gao H; Geng XP; Wang BH; Zhou Y
J Colloid Interface Sci; 2010 Apr; 344(2):468-74. PubMed ID: 20138631
[TBL] [Abstract][Full Text] [Related]
5. Influence of carbides and microstructure of CoCrMo alloys on their metallic dissolution resistance.
Valero-Vidal C; Casabán-Julián L; Herraiz-Cardona I; Igual-Muñoz A
Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4667-76. PubMed ID: 24094174
[TBL] [Abstract][Full Text] [Related]
6. Effect of surface area enhancement on the adsorption of Bovine Serum Albumin onto titanium dioxide.
Kopac T; Bozgeyik K
Colloids Surf B Biointerfaces; 2010 Mar; 76(1):265-71. PubMed ID: 20005083
[TBL] [Abstract][Full Text] [Related]
7. Protein adsorption at solid-liquid interfaces: Part IV--Effects of different solid-liquid systems and various neutral salts.
Hajra S; Chattoraj DK
Indian J Biochem Biophys; 1991 Aug; 28(4):267-79. PubMed ID: 1752629
[TBL] [Abstract][Full Text] [Related]
8. A novel dual-impedance-analysis EQCM system--investigation of bovine serum albumin adsorption on gold and platinum electrode surfaces.
Xie Q; Xiang C; Yuan Y; Zhang Y; Nie L; Yao S
J Colloid Interface Sci; 2003 Jun; 262(1):107-15. PubMed ID: 16256587
[TBL] [Abstract][Full Text] [Related]
9. Thermosensitive-polymer-coated magnetic nanoparticles: adsorption and desorption of bovine serum albumin.
Shamim N; Hong L; Hidajat K; Uddin MS
J Colloid Interface Sci; 2006 Dec; 304(1):1-8. PubMed ID: 17010360
[TBL] [Abstract][Full Text] [Related]
10. pH/temperature - sensitive imprinted ionic poly(N-tert-butylacrylamide-co-acrylamide/maleic acid) hydrogels for bovine serum albumin.
Demirel G; Ozçetin G; Turan E; Caykara T
Macromol Biosci; 2005 Oct; 5(10):1032-7. PubMed ID: 16208634
[TBL] [Abstract][Full Text] [Related]
11. Electrochemical behavior of CoCrMo alloy for dental applications in acidic artificial saliva containing albumin.
Yang L; Zhu Q; Xie X; Cao X; Wu Y; Chen S; Qu JE
Colloids Surf B Biointerfaces; 2019 Dec; 184():110492. PubMed ID: 31522026
[TBL] [Abstract][Full Text] [Related]
12. Influence of the sliding velocity and the applied potential on the corrosion and wear behavior of HC CoCrMo biomedical alloy in simulated body fluids.
Gil RA; Muñoz AI
J Mech Behav Biomed Mater; 2011 Nov; 4(8):2090-102. PubMed ID: 22098909
[TBL] [Abstract][Full Text] [Related]
13. An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: the influence of pH variation.
Royhman D; Radhakrishnan R; Yuan JC; Mathew MT; Mercuri LG; Sukotjo C
J Craniomaxillofac Surg; 2014 Oct; 42(7):1052-61. PubMed ID: 24548869
[TBL] [Abstract][Full Text] [Related]
14. Bovine serum albumin adsorption on nano-rough platinum surfaces studied by QCM-D.
Dolatshahi-Pirouz A; Rechendorff K; Hovgaard MB; Foss M; Chevallier J; Besenbacher F
Colloids Surf B Biointerfaces; 2008 Oct; 66(1):53-9. PubMed ID: 18586468
[TBL] [Abstract][Full Text] [Related]
15. Characterization of implant materials in fetal bovine serum and sodium sulfate by electrochemical impedance spectroscopy. II. Coarsely sandblasted samples.
Contu F; Elsener B; Böhni H
J Biomed Mater Res A; 2003 Oct; 67(1):246-54. PubMed ID: 14517883
[TBL] [Abstract][Full Text] [Related]
16. Hydrophobic interaction chromatography of proteins: thermodynamic analysis of conformational changes.
Ueberbacher R; Rodler A; Hahn R; Jungbauer A
J Chromatogr A; 2010 Jan; 1217(2):184-90. PubMed ID: 19501365
[TBL] [Abstract][Full Text] [Related]
17. Characterization of implant materials in fetal bovine serum and sodium sulfate by electrochemical impedance spectroscopy. I. Mechanically polished samples.
Contu F; Elsener B; Böhni H
J Biomed Mater Res; 2002 Dec; 62(3):412-21. PubMed ID: 12209927
[TBL] [Abstract][Full Text] [Related]
18. PM-IRRAS investigation of the interaction of serum albumin and fibrinogen with a biomedical-grade stainless steel 316LVM surface.
Desroches MJ; Chaudhary N; Omanovic S
Biomacromolecules; 2007 Sep; 8(9):2836-44. PubMed ID: 17715960
[TBL] [Abstract][Full Text] [Related]
19. In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids.
Igual Munoz A; Schwiesau J; Jolles BM; Mischler S
Acta Biomater; 2015 Jul; 21():228-36. PubMed ID: 25797841
[TBL] [Abstract][Full Text] [Related]
20. Interfacial biocatalysis on charged and immobilized substrates: the roles of enzyme and substrate surface charge.
Feller BE; Kellis JT; Cascão-Pereira LG; Robertson CR; Frank CW
Langmuir; 2011 Jan; 27(1):250-63. PubMed ID: 21128607
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]