BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 20559132)

  • 1. Biomechanics of the aortic valve in the continuous flow VAD-assisted heart.
    May-Newman K; Enriquez-Almaguer L; Posuwattanakul P; Dembitsky W
    ASAIO J; 2010; 56(4):301-8. PubMed ID: 20559132
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of aortic valve incompetence on the hemodynamics of a continuous flow ventricular assist device in a mock circulation.
    Zamarripa Garcia MA; Enriquez LA; Dembitsky W; May-Newman K
    ASAIO J; 2008; 54(3):237-44. PubMed ID: 18496272
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Geometry and fusion of aortic valves from pulsatile flow ventricular assist device patients.
    May-Newman K; Mendoza A; Abulon DJ; Joshi M; Kunda A; Dembitsky W
    J Heart Valve Dis; 2011 Mar; 20(2):149-58. PubMed ID: 21560813
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.
    Tuzun E; Rutten M; Dat M; van de Vosse F; Kadipasaoglu C; de Mol B
    J Surg Res; 2011 Dec; 171(2):443-7. PubMed ID: 20828746
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro.
    Jennings LM; Butterfield M; Walker PG; Watterson KG; Fisher J
    J Heart Valve Dis; 2001 Mar; 10(2):269-75. PubMed ID: 11297215
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel pulse duplicator system: evaluation of different valve prostheses.
    Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G
    Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Age-related changes in the aortic valve affect leaflet stress distributions: implications for aortic valve degeneration.
    Singh R; Strom JA; Ondrovic L; Joseph B; VanAuker MD
    J Heart Valve Dis; 2008 May; 17(3):290-8; discussion 299. PubMed ID: 18592926
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation.
    Litwak KN; Koenig SC; Cheng RC; Giridharan GA; Gillars KJ; Pantalos GM
    Artif Organs; 2005 Aug; 29(8):629-35. PubMed ID: 16048479
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of aortic valve pressure overload and leaflet functions in an ex vivo beating heart loaded with a continuous flow cardiac assist device.
    Tuzun E; Pennings K; van Tuijl S; de Hart J; Stijnen M; van de Vosse F; de Mol B; Rutten M
    Eur J Cardiothorac Surg; 2014 Feb; 45(2):377-83. PubMed ID: 23818568
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pathology in patients with ventricular assist devices: a study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts.
    Rose AG; Park SJ
    Cardiovasc Pathol; 2005; 14(1):19-23. PubMed ID: 15710287
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predicting ATS Open Pivot heart valve performance with computational fluid dynamics.
    Dumont K; Vierendeels JA; Segers P; Van Nooten GJ; Verdonck PR
    J Heart Valve Dis; 2005 May; 14(3):393-9. PubMed ID: 15974535
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Physiological basis of flow dependence of Gorlin formula valve area in aortic stenosis: analysis using an hydraulic model of pulsatile flow.
    Rifkin RD
    J Heart Valve Dis; 2000 Nov; 9(6):740-51. PubMed ID: 11128779
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tubular heart valves: a new tissue prosthesis design--preclinical evaluation of the 3F aortic bioprosthesis.
    Cox JL; Ad N; Myers K; Gharib M; Quijano RC
    J Thorac Cardiovasc Surg; 2005 Aug; 130(2):520-7. PubMed ID: 16077422
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Numerical simulation of cardiovascular dynamics with left heart failure and in-series pulsatile ventricular assist device.
    Shi Y; Korakianitis T
    Artif Organs; 2006 Dec; 30(12):929-48. PubMed ID: 17181834
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].
    Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analysis of flow within a left ventricle model fully assisted with continuous flow through the aortic valve.
    Yano T; Funayama M; Sudo S; Mitamura Y
    Artif Organs; 2012 Aug; 36(8):714-23. PubMed ID: 22882441
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In-vitro assessment of the functional performance of the decellularized intact porcine aortic root.
    Korossis SA; Wilcox HE; Watterson KG; Kearney JN; Ingham E; Fisher J
    J Heart Valve Dis; 2005 May; 14(3):408-21; discussion 422. PubMed ID: 15974537
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Problems in patients with use of a ventricular assist device].
    Nishimura K; Yamazato A; Aoshima M; Fukumasu H; Kubo S; Hirata K; Okabayashi H; Nomoto S; Okamoto Y; Ban T
    J Cardiol; 1990; 20(2):473-82. PubMed ID: 2104421
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and validation of a computational fluid dynamics methodology for simulation of pulsatile left ventricular assist devices.
    Medvitz RB; Kreider JW; Manning KB; Fontaine AA; Deutsch S; Paterson EG
    ASAIO J; 2007; 53(2):122-31. PubMed ID: 17413548
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.