These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 2055923)

  • 1. Aortic dissection type A surgery: Doppler sonography to evaluate correct carotid artery perfusion during cardiopulmonary bypass.
    Antona C; Agrifoglio M; Alamanni F; Spirito R; Polvani GL; Biglioli P
    J Cardiovasc Surg (Torino); 1991; 32(3):307-9. PubMed ID: 2055923
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Moderately hypothermic cardiopulmonary bypass and selective cerebral perfusion in ascending aorta and aortic arch surgery. Preliminary experience in twenty-two patients.
    Testolin L; Roques X; Laborde MN; Roques F; Mukai S; Baudet E
    Cardiovasc Surg; 1998 Aug; 6(4):398-405. PubMed ID: 9725520
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aortic arch cannulation with the guidance of transesophageal echocardiography for Stanford type A aortic dissection.
    Ma H; Xiao Z; Shi J; Liu L; Qin C; Guo Y
    J Cardiothorac Surg; 2018 Oct; 13(1):106. PubMed ID: 30309362
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic arch surgery using moderate systemic hypothermia and antegrade cerebral perfusion via the right subclavian artery.
    Aebert H; Reber D; Kobuch R; Philipp A; Birnbaum DE
    Thorac Cardiovasc Surg; 2001 Oct; 49(5):283-6. PubMed ID: 11605138
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Aortic arch surgery with bilateral cerebral perfusion by isolation of brachiocephalic trunk and left carotid artery].
    Carreira VJ; de Oliveira DM; Honório JF; Pinheiro IT; Chissonde EM; Faria RM
    Rev Bras Cir Cardiovasc; 2008; 23(1):70-7. PubMed ID: 18719831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predictors of Outcomes after Correction of Acute Type A Aortic Dissection under Moderate Hypothermic Circulatory Arrest and Antegrade Cerebral Perfusion.
    Samanidis G; Katselis C; Contrafouris C; Georgiopoulos G; Kriaras I; Antoniou T; Perreas K
    Braz J Cardiovasc Surg; 2018; 33(2):143-150. PubMed ID: 29898143
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Axillary cerebral perfusion for arch surgery in acute type A dissection under moderate hypothermia.
    Panos A; Murith N; Bednarkiewicz M; Khatchatourov G
    Eur J Cardiothorac Surg; 2006 Jun; 29(6):1036-9. PubMed ID: 16675240
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Safety and efficacy of ascending aorta cannulation during repair of acute type A aortic dissection (PA29-04): "Presented at the 65th Annual Scientific Meeting of the Japanese Association for Thoracic Surgery".
    Osumi M; Wada H; Morita Y; Shimizu M; Sukehiro Y; Amako M; Minematsu N; Matsumura H; Nishimi M; Tashiro T
    Gen Thorac Cardiovasc Surg; 2014 May; 62(5):296-300. PubMed ID: 24310294
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Axillary artery cannulation: routine use in ascending aorta and aortic arch replacement.
    Strauch JT; Spielvogel D; Lauten A; Lansman SL; McMurtry K; Bodian CA; Griepp RB
    Ann Thorac Surg; 2004 Jul; 78(1):103-8; discussion 103-8. PubMed ID: 15223412
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative study of brain protection in ascending aorta replacement for acute type A aortic dissection: retrograde cerebral perfusion versus selective antegrade cerebral perfusion.
    Sugiura T; Imoto K; Uchida K; Minami T; Yasuda S
    Gen Thorac Cardiovasc Surg; 2012 Oct; 60(10):645-8. PubMed ID: 22903579
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cerebral monitoring with transcranial Doppler ultrasonography improves neurologic outcome during repairs of acute type A aortic dissection.
    Estrera AL; Garami Z; Miller CC; Sheinbaum R; Huynh TT; Porat EE; Allen BS; Safi HJ
    J Thorac Cardiovasc Surg; 2005 Feb; 129(2):277-85. PubMed ID: 15678036
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraoperative echocardiography for diagnosis and treatment of aortic dissection. Utility of color flow mapping for surgical decision making in acute stage.
    Kyo S; Takamoto S; Omoto R; Matsumura M; Kimura S; Neya K; Adachi H; Yokote Y
    Herz; 1992 Dec; 17(6):377-89. PubMed ID: 1483626
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ascending aorta cannulation in acute type A aortic dissection.
    Inoue Y; Ueda T; Taguchi S; Kashima I; Koizumi K; Takahashi R; Kiso I
    Eur J Cardiothorac Surg; 2007 Jun; 31(6):976-9; discussion 979-81. PubMed ID: 17320407
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Color-flow Doppler recognition of intraoperative brachiocephalic malperfusion during operative repair of acute type a aortic dissection: utility of transcutaneous carotid artery ultrasound scanning.
    Augoustides JG; Kohl BA; Harris H; Pochettino A
    J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):81-4. PubMed ID: 17289485
    [No Abstract]   [Full Text] [Related]  

  • 15. Bailout percutaneous external shunt to restore carotid flow in a patient with acute type A aortic dissection and carotid occlusion.
    Schönholz C; Ikonomidis JS; Hannegan C; Mendaro E
    J Endovasc Ther; 2008 Dec; 15(6):639-42. PubMed ID: 19090632
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcutaneous ultrasound measurements of carotid flow to monitor for cerebral malperfusion during type-A aortic dissection repair.
    Pulido JN; Pallohusky BS; Park SJ; Cook DJ
    J Cardiothorac Vasc Anesth; 2013 Aug; 27(4):728-30. PubMed ID: 22534411
    [No Abstract]   [Full Text] [Related]  

  • 17. Obstruction of the true lumen during retrograde perfusion of type I aortic dissections: a simplified solution.
    Parr GV; Manley NJ; Williams DR; Montesano RM
    Ann Thorac Surg; 1980 Nov; 30(5):495-8. PubMed ID: 7436622
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.
    Inoue Y; Takahashi R; Ueda T; Yozu R
    J Thorac Cardiovasc Surg; 2011 Feb; 141(2):354-60. PubMed ID: 21241859
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Repair of the aortic arch with left unilateral selective cerebral perfusion.
    Akgul A; Ozatik MA; Kucuker SA; Bahar I; Tasdemir O
    Perfusion; 2004 Jan; 19(1):77-9. PubMed ID: 15072260
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Surgical treatment of the aortic arch dissection--a report of two cases operated by partial brachiocephalic perfusion, and open aortic anastomosis].
    Aoyagi S; Akashi H; Kubota Y; Fujino T; Kosuga K; Oishi K
    Nihon Kyobu Geka Gakkai Zasshi; 1991 Jun; 39(6):974-8. PubMed ID: 1894979
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.