These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Forced oscillation technique. Reference values for resistance and reactance over a frequency spectrum of 2-26 Hz in healthy children aged 2.3-12.5 years. Duiverman EJ; Clément J; van de Woestijne KP; Neijens HJ; van den Bergh AC; Kerrebijn KF Bull Eur Physiopathol Respir; 1985; 21(2):171-8. PubMed ID: 3995199 [TBL] [Abstract][Full Text] [Related]
4. Reference values of total respiratory resistance and reactance between 4 and 26 Hz in children and adolescents aged 4-20 years. Clément J; Dumoulin B; Gubbelmans R; Hendriks S; van de Woestijne KP Bull Eur Physiopathol Respir; 1987; 23(5):441-8. PubMed ID: 3450326 [TBL] [Abstract][Full Text] [Related]
5. Respiratory system reactance as an indicator of the intrathoracic airway response to methacholine in children. Bouaziz N; Beyaert C; Gauthier R; Monin P; Peslin R; Marchal F Pediatr Pulmonol; 1996 Jul; 22(1):7-13. PubMed ID: 8856798 [TBL] [Abstract][Full Text] [Related]
6. Effect of rib cage and abdominal restriction on total respiratory resistance and reactance. van Noord JA; Demedts M; Clément J; Cauberghs M; Van de Woestijne KP J Appl Physiol (1985); 1986 Nov; 61(5):1736-40. PubMed ID: 3781983 [TBL] [Abstract][Full Text] [Related]
7. Colored 3-dimensional analyses of respiratory resistance and reactance in COPD and asthma. Mori K; Shirai T; Mikamo M; Shishido Y; Akita T; Morita S; Asada K; Fujii M; Suda T; Chida K COPD; 2011 Dec; 8(6):456-63. PubMed ID: 22149407 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of impulse oscillation system: comparison with forced oscillation technique and body plethysmography. Hellinckx J; Cauberghs M; De Boeck K; Demedts M Eur Respir J; 2001 Sep; 18(3):564-70. PubMed ID: 11589356 [TBL] [Abstract][Full Text] [Related]
9. Total respiratory resistance and reactance in ankylosing spondylitis and kyphoscoliosis. van Noord JA; Cauberghs M; Van de Woestijne KP; Demedts M Eur Respir J; 1991 Sep; 4(8):945-51. PubMed ID: 1783085 [TBL] [Abstract][Full Text] [Related]
10. Values of impulse oscillometry in healthy mexican children and adolescents. Gochicoa-Rangel L; Torre-Bouscoulet L; Martínez-Briseño D; Rodríguez-Moreno L; Cantú-González G; Vargas MH Respir Care; 2015 Jan; 60(1):119-27. PubMed ID: 25336530 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of airway responsiveness using colored three-dimensional analyses of a new forced oscillation technique in controlled asthmatic and nonasthmatic children. Murakami K; Habukawa C; Kurosawa H; Takemura T Respir Investig; 2014 Jan; 52(1):57-64. PubMed ID: 24388372 [TBL] [Abstract][Full Text] [Related]
12. Correspondence between forced oscillation and body plethysmography during bronchoprovocation with carbachol in children. Buhr W; Jörres R; Berdel D; Làndsér FJ Pediatr Pulmonol; 1990; 8(4):280-8. PubMed ID: 2196514 [TBL] [Abstract][Full Text] [Related]
13. Input respiratory impedance measured by head generator in preschool children. Mazurek H; Willim G; Marchal F; Haluszka J; Tomalak W Pediatr Pulmonol; 2000 Jul; 30(1):47-55. PubMed ID: 10862162 [TBL] [Abstract][Full Text] [Related]
14. Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children. Park JH; Yoon JW; Shin YH; Jee HM; Wee YS; Chang SJ; Sim JH; Yum HY; Han MY Korean J Pediatr; 2011 Feb; 54(2):64-8. PubMed ID: 21503199 [TBL] [Abstract][Full Text] [Related]
15. Lung function measured by the oscillometric method in prematurely born children with chronic lung disease. Malmberg LP; Mieskonen S; Pelkonen A; Kari A; Sovijärvi AR; Turpeinen M Eur Respir J; 2000 Oct; 16(4):598-603. PubMed ID: 11106198 [TBL] [Abstract][Full Text] [Related]
16. Reference values for respiratory sinusoidal oscillometry in children aged 3 to 17 years. Ducharme FM; Smyrnova A; Lawson CC; Miles LM Pediatr Pulmonol; 2022 Sep; 57(9):2092-2102. PubMed ID: 35578568 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of impulse oscillometry in pigs of unknown disease status originating from the field. Püllen C; Becker S; Smith HJ; Reinhold P; Reiner G Vet J; 2014 Jul; 201(1):78-82. PubMed ID: 24888679 [TBL] [Abstract][Full Text] [Related]
18. Regression Equations of Respiratory Impedance Measured by Forced Oscillation Technique for Indian Children. De S; Banerjee N; Tiwari RR Indian J Pediatr; 2020 Mar; 87(3):192-199. PubMed ID: 31863388 [TBL] [Abstract][Full Text] [Related]
19. Reference value of impulse oscillometry in taiwanese preschool children. Lai SH; Yao TC; Liao SL; Tsai MH; Hua MC; Yeh KW; Huang JL Pediatr Neonatol; 2015 Jun; 56(3):165-70. PubMed ID: 25454078 [TBL] [Abstract][Full Text] [Related]
20. Specific airway resistance, interrupter resistance, and respiratory impedance in healthy children aged 2-7 years. Klug B; Bisgaard H Pediatr Pulmonol; 1998 May; 25(5):322-31. PubMed ID: 9635934 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]