These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 20579197)

  • 1. Effectiveness of the auscultatory and pH methods in predicting feeding tube placement.
    Turgay AS; Khorshid L
    J Clin Nurs; 2010 Jun; 19(11-12):1553-9. PubMed ID: 20579197
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effectiveness of pH measurements in predicting feeding tube placement.
    Metheny N; Williams P; Wiersema L; Wehrle MA; Eisenberg P; McSweeney M
    Nurs Res; 1989; 38(5):280-5. PubMed ID: 2508068
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effectiveness of pH measurements in predicting feeding tube placement: an update.
    Metheny N; Reed L; Wiersema L; McSweeney M; Wehrle MA; Clark J
    Nurs Res; 1993; 42(6):324-31. PubMed ID: 8247814
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hold that x-ray: aspirate pH and auscultation prove enteral tube placement.
    Neumann MJ; Meyer CT; Dutton JL; Smith R
    J Clin Gastroenterol; 1995 Jun; 20(4):293-5. PubMed ID: 7665817
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Litmus tests for verification of feeding tube location in infants: evaluation of their clinical use.
    Nyqvist KH; Sorell A; Ewald U
    J Clin Nurs; 2005 Apr; 14(4):486-95. PubMed ID: 15807756
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effectiveness of the auscultatory method in predicting feeding tube location.
    Metheny N; McSweeney M; Wehrle MA; Wiersema L
    Nurs Res; 1990; 39(5):262-7. PubMed ID: 2119031
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reliability of pH measurement and the auscultatory method to confirm the position of a nasogastric tube.
    Boeykens K; Steeman E; Duysburgh I
    Int J Nurs Stud; 2014 Nov; 51(11):1427-33. PubMed ID: 24731474
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a reliable and valid bedside test for bilirubin and its utility for improving prediction of feeding tube location.
    Metheny NA; Smith L; Stewart BJ
    Nurs Res; 2000; 49(6):302-9. PubMed ID: 11093694
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transnasal endoscopy for enteral feeding tube placement in critically ill patients.
    Dranoff JA; Angood PJ; Topazian M
    Am J Gastroenterol; 1999 Oct; 94(10):2902-4. PubMed ID: 10520841
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of a practical pH cutoff level for reliable confirmation of nasogastric tube placement.
    Gilbertson HR; Rogers EJ; Ukoumunne OC
    JPEN J Parenter Enteral Nutr; 2011 Jul; 35(4):540-4. PubMed ID: 21622643
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blind insertion of feeding tubes in intensive care units: a national survey.
    Metheny NA; Stewart BJ; Mills AC
    Am J Crit Care; 2012 Sep; 21(5):352-60. PubMed ID: 22941709
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Feeding tube placement: auscultatory method and x-ray agreement].
    Beghetto MG; Anziliero F; LeĆ£es DM; de Mello ED
    Rev Gaucha Enferm; 2015 Dec; 36(4):98-103. PubMed ID: 26735765
    [TBL] [Abstract][Full Text] [Related]  

  • 13. pH and concentration of bilirubin in feeding tube aspirates as predictors of tube placement.
    Metheny NA; Stewart BJ; Smith L; Yan H; Diebold M; Clouse RE
    Nurs Res; 1999; 48(4):189-97. PubMed ID: 10414681
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Methods to confirm feeding tube placement: application of research in practice.
    Huffman S; Pieper P; Jarczyk KS; Bayne A; O'Brien E
    Pediatr Nurs; 2004; 30(1):10-3. PubMed ID: 15022846
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effectiveness of auscultatory, colorimetric capnometry and pH measurement methods to confirm placement of nasogastric tubes: A methodological study.
    Taskiran N; Sari D
    Int J Nurs Pract; 2022 Apr; 28(2):e13049. PubMed ID: 35285146
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Jejunal feeding tubes can be efficiently and independently placed by intensive care unit teams.
    Welpe P; Frutiger A; Vanek P; Kleger GR
    JPEN J Parenter Enteral Nutr; 2010; 34(2):121-4. PubMed ID: 20067951
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Endoscopic position control of nasoenteral feeding tubes by transnasal re-endoscopy: a prospective study in intensive care patients.
    Wiegand N; Bauerfeind P; Delco F; Fried M; Wildi SM
    Am J Gastroenterol; 2009 May; 104(5):1271-6. PubMed ID: 19319127
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Nasoenteral feeding tube placement by nurses using an electromagnetic guidance system (with video).
    Mathus-Vliegen EM; Duflou A; Spanier MB; Fockens P
    Gastrointest Endosc; 2010 Apr; 71(4):728-36. PubMed ID: 20170911
    [TBL] [Abstract][Full Text] [Related]  

  • 19. pH and concentrations of pepsin and trypsin in feeding tube aspirates as predictors of tube placement.
    Metheny NA; Stewart BJ; Smith L; Yan H; Diebold M; Clouse RE
    JPEN J Parenter Enteral Nutr; 1997; 21(5):279-85. PubMed ID: 9323690
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimizing respiratory complications of nasoenteric tube feedings: state of the science.
    Metheny N
    Heart Lung; 1993; 22(3):213-23. PubMed ID: 8491657
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.