These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 2057993)

  • 1. Measurement of plasma clonazepam for therapeutic control: a comparison of chromatographic methods.
    de Carvalho D; Lanchote VL
    Ther Drug Monit; 1991 Jan; 13(1):55-63. PubMed ID: 2057993
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Direct determination of clonazepam (Rivotril) and 7-amino clonazepam in plasma by gas-chromatography (author's transl)].
    Cano JP; Gouezo F; Lindoulsi T; Viala A
    Toxicol Eur Res; 1979 Jan; 2(1):25-33. PubMed ID: 483320
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of clonazepam ("Rivotril" or "Ro 5-4023") in plasma by gas chromatography using an internal standard.
    Cano JP; Catalin J; Viala A; Roger J; Tassinari CA; Dravet C; Gastraut H
    Eur J Toxicol Environ Hyg; 1976; 9(4):213-25. PubMed ID: 976330
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A methods comparison: clonazepam by gas chromatography-electron capture and gas chromatography-mass spectroscopy.
    Wilson JM; Friel PN; Wilensky AJ; Raisys VA
    Ther Drug Monit; 1979; 1(3):387-97. PubMed ID: 555581
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved micromethod for determination of underivatized clonazepam in serum by gas chromatography.
    Edelbroek PM; De Wolff FA
    Clin Chem; 1978 Oct; 24(10):1774-7. PubMed ID: 699288
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid gas chromatographic assay of underivatized clonazepam in plasma.
    Löscher W; Al-Tahan FJ
    Ther Drug Monit; 1983 Jun; 5(2):229-33. PubMed ID: 6879649
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assay of underivatized intrazepam and clonazepam in plasma by capillary gas chromatography applied to pharmacokinetic and bioavailability studies in humans.
    de Boer AG; Röst-Kaiser J; Bracht H; Breimer DD
    J Chromatogr; 1978 Jan; 145(1):105-14. PubMed ID: 621234
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improved gas chromatographic procedure for the determination of clonazepam levels in plasma using a nitrogen-sensitive detector.
    Dhar AK; Kutt H
    J Chromatogr; 1981 Feb; 222(2):203-11. PubMed ID: 7251738
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clonazepam quantification in human plasma by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry in a bioequivalence study.
    Cavedal LE; Mendes FD; Domingues CC; Patni AK; Monif T; Reyar S; Pereira Ados S; Mendes GD; De Nucci G
    J Mass Spectrom; 2007 Jan; 42(1):81-8. PubMed ID: 17154437
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of flunitrazepam, desmethylflunitrazepam and clonazepam in plasma by gas liquid chromatography with an internal standard.
    Cano JP; Guintrand J; Aubert C; Viala A
    Arzneimittelforschung; 1977 Feb; 27(2):338-42. PubMed ID: 16619
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Extraction and analysis of clonazepam and 7-aminoclonazepam in whole blood using a dual internal standard methodology.
    Hackett J; Elian AA
    Forensic Sci Int; 2007 Mar; 166(2-3):209-17. PubMed ID: 16809012
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The measurement of Rivotril in whole blood by gas liquid chromatography.
    Shapcott D; Lemieux B
    Clin Biochem; 1975 Aug; 8(4):283-7. PubMed ID: 1157296
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Determination of unchanged clonazepam in plasma by gas-liquid chromatography].
    Marliac Y; Barazi S
    Ann Biol Clin (Paris); 1989; 47(8):503-6. PubMed ID: 2690682
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simple and specific high performance liquid chromatographic method for the routine monitoring of clonazepam in plasma.
    Rovei V; Sanjuan M
    Ther Drug Monit; 1980; 2(3):283-7. PubMed ID: 7222182
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of clonazepam by electron-capture gas-liquid chromatography with application to single-dose pharmacokinetics.
    Miller LG; Friedman H; Greenblatt DJ
    J Anal Toxicol; 1987; 11(2):55-7. PubMed ID: 3573724
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Micro-determination of clonazepam in plasma or serum by electron-capture gas-liquid chromatography.
    Badcock NR; Pollard AC
    J Chromatogr; 1982 Jul; 230(2):353-61. PubMed ID: 7107781
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative determination of clonazepam in plasma by gas chromatography-negative ion chemical ionization mass spectrometry.
    Song D; Zhang S; Kohlhof K
    J Chromatogr B Biomed Appl; 1996 Nov; 686(2):199-204. PubMed ID: 8971600
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simple and sensitive gas chromatographic method for the determination of clonazepam in human plasma.
    Gerna M; Morselli PL
    J Chromatogr; 1976 Jan; 116(2):445-50. PubMed ID: 1245581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of two gas-liquid chromatographic methods for the determination of nitrazepam in plasma.
    Kangas L
    J Chromatogr; 1977 Jun; 136(2):259-70. PubMed ID: 885966
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a rapid RP-HPLC method for the determination of clonazepam in human plasma.
    Bares IF; Pehourcq F; Jarry C
    J Pharm Biomed Anal; 2004 Nov; 36(4):865-9. PubMed ID: 15533681
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.