BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

586 related articles for article (PubMed ID: 20581425)

  • 1. Performance of low-voltage STEM/TEM with delta corrector and cold field emission gun.
    Sasaki T; Sawada H; Hosokawa F; Kohno Y; Tomita T; Kaneyama T; Kondo Y; Kimoto K; Sato Y; Suenaga K
    J Electron Microsc (Tokyo); 2010 Aug; 59 Suppl 1():S7-13. PubMed ID: 20581425
    [TBL] [Abstract][Full Text] [Related]  

  • 2. STEM imaging of 47-pm-separated atomic columns by a spherical aberration-corrected electron microscope with a 300-kV cold field emission gun.
    Sawada H; Tanishiro Y; Ohashi N; Tomita T; Hosokawa F; Kaneyama T; Kondo Y; Takayanagi K
    J Electron Microsc (Tokyo); 2009 Dec; 58(6):357-61. PubMed ID: 19546144
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aberration-corrected STEM/TEM imaging at 15kV.
    Sasaki T; Sawada H; Hosokawa F; Sato Y; Suenaga K
    Ultramicroscopy; 2014 Oct; 145():50-5. PubMed ID: 24842229
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Atomic-resolution STEM in the aberration-corrected JEOL JEM2200FS.
    Klie RF; Johnson C; Zhu Y
    Microsc Microanal; 2008 Feb; 14(1):104-12. PubMed ID: 18171499
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Atomic-Resolution STEM Imaging of Graphene at Low Voltage of 30 kV with Resolution Enhancement by Using Large Convergence Angle.
    Sawada H; Sasaki T; Hosokawa F; Suenaga K
    Phys Rev Lett; 2015 Apr; 114(16):166102. PubMed ID: 25955058
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative annular dark-field STEM images of a silicon crystal using a large-angle convergent electron probe with a 300-kV cold field-emission gun.
    Kim S; Oshima Y; Sawada H; Kaneyama T; Kondo Y; Takeguchi M; Nakayama Y; Tanishiro Y; Takayanagi K
    J Electron Microsc (Tokyo); 2011; 60(2):109-16. PubMed ID: 21247969
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resolving 45-pm-separated Si-Si atomic columns with an aberration-corrected STEM.
    Sawada H; Shimura N; Hosokawa F; Shibata N; Ikuhara Y
    Microscopy (Oxf); 2015 Jun; 64(3):213-7. PubMed ID: 25825509
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lattice imaging at an accelerating voltage of 30kV using an in-lens type cold field-emission scanning electron microscope.
    Konno M; Ogashiwa T; Sunaoshi T; Orai Y; Sato M
    Ultramicroscopy; 2014 Oct; 145():28-35. PubMed ID: 24290787
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Resolution enhancement at a large convergence angle by a delta corrector with a CFEG in a low-accelerating-voltage STEM.
    Sawada H; Sasaki T; Hosokawa F; Suenaga K
    Micron; 2014 Aug; 63():35-9. PubMed ID: 24618015
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First experimental test of a new monochromated and aberration-corrected 200 kV field-emission scanning transmission electron microscope.
    Walther T; Quandt E; Stegmann H; Thesen A; Benner G
    Ultramicroscopy; 2006; 106(11-12):963-9. PubMed ID: 16870338
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Retro-fitting an older (S)TEM with two Cs aberration correctors for 80 kV and 60 kV operation.
    Börrnert F; Bachmatiuk A; Gorantla S; Wolf D; Lubk A; Büchner B; Rümmeli MH
    J Microsc; 2013 Feb; 249(2):87-92. PubMed ID: 23176667
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental evaluation of a spherical aberration-corrected TEM and STEM.
    Sawada H; Tomita T; Naruse M; Honda T; Hambridge P; Hartel P; Haider M; Hetherington C; Doole R; Kirkland A; Hutchison J; Titchmarsh J; Cockayne D
    J Electron Microsc (Tokyo); 2005 Apr; 54(2):119-21. PubMed ID: 15972729
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cs-corrected HAADF-STEM imaging of silicate minerals.
    Kogure T; Okunishi E
    J Electron Microsc (Tokyo); 2010; 59(4):263-71. PubMed ID: 20167574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lattice imaging in low-angle and high-angle bright-field scanning transmission electron microscopy.
    Watanabe K; Kikuchi Y; Yamazaki T; Asano E; Nakanishi N; Kotaka Y; Okunishi E; Hashimoto I
    Acta Crystallogr A; 2004 Nov; 60(Pt 6):591-7. PubMed ID: 15507742
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of residual aberration in fifth-order geometrical aberration correctors.
    Morishita S; Kohno Y; Hosokawa F; Suenaga K; Sawada H
    Microscopy (Oxf); 2018 Jun; 67(3):156-163. PubMed ID: 29474670
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transmission electron microscopy at 20 kV for imaging and spectroscopy.
    Kaiser U; Biskupek J; Meyer JC; Leschner J; Lechner L; Rose H; Stöger-Pollach M; Khlobystov AN; Hartel P; Müller H; Haider M; Eyhusen S; Benner G
    Ultramicroscopy; 2011 Jul; 111(8):1239-46. PubMed ID: 21801697
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performances of an 80-200 kV microscope employing a cold-FEG and an aberration-corrected objective lens.
    Ricolleau C; Nelayah J; Oikawa T; Kohno Y; Braidy N; Wang G; Hue F; Florea L; Pierron Bohnes V; Alloyeau D
    Microscopy (Oxf); 2013 Apr; 62(2):283-93. PubMed ID: 23160361
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The formation and utility of sub-angstrom to nanometer-sized electron probes in the aberration-corrected transmission electron microscope at the University of Illinois.
    Wen J; Mabon J; Lei C; Burdin S; Sammann E; Petrov I; Shah AB; Chobpattana V; Zhang J; Ran K; Zuo JM; Mishina S; Aoki T
    Microsc Microanal; 2010 Apr; 16(2):183-93. PubMed ID: 20187990
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prerequisites for a Cc/Cs-corrected ultrahigh-resolution TEM.
    Haider M; Müller H; Uhlemann S; Zach J; Loebau U; Hoeschen R
    Ultramicroscopy; 2008 Feb; 108(3):167-78. PubMed ID: 18060700
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of chromatic aberration on atomic-resolved spherical aberration corrected STEM images.
    Kuramochi K; Yamazaki T; Kotaka Y; Ohtsuka M; Hashimoto I; Watanabe K
    Ultramicroscopy; 2009 Dec; 110(1):36-42. PubMed ID: 19818560
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 30.